AC-DC Power Supplies Medical Type Power Safety EMI OCP OVP Medical World wide Inrush Remote Factor Approvals electric current ON/OFF Correction equipment limiting PMA-series Feature CE marking For medical electric equipment Low Voltage Drective Internal dual fuses RoHS Directive Harmonic attenuator (Complies with IEC61000-3-2) Universal input (AC85 - 264V) EMS Compliance : EN61204-3, EN61000-6-2 Efficiency increased with synchronous rectification EN61000-4-2 technology (PMA60F, PMA100F) EN61000-4-3 Variety of option EN61000-4-4 EN61000-4-5 (Common mode Level4, Differential mode Level2) Safety agency approvals EN61000-4-6 UL60601-1, C-UL (CSA-C22.2 No.601.1), EN60601-1 EN61000-4-8 EN61000-4-11 EMI FCC-B, CISPR11-B, CISPR22-B, EN55011-B, EN55022-B, VCCI-B 5-year warranty (refer to Instruction Manual) July 01, 2020 PMA-1Ordering information AC-DC Power Supplies Medical Type PM A 15 F -O -O PMA15F 1 2 3 4 5 6 1 Series name Example recommended EMI/EMC filter R 2 Single output NAM-04-000 3 Output wattage 4 Universal input 5 Output voltage 6 Optional *5 T : Vertical terminal block T1 : Horizontal terminal block N : with Cover Low leakage current type : NAM series J1 : VH(J.S.T.)connector type * A higher current rating EMI/EMC filter may be recommended in view of the other devices that could be connected in parallel with the power supply. Specification is changed at option, refer to Instruction Manual. Horizontal terminal block Vertical terminal block Standard type with Cover (option : -T1) (option : -T) (option : -N) *Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations. MODEL PMA15F-3R3 PMA15F-5 PMA15F-12 PMA15F-15 PMA15F-24 MAX OUTPUT WATTAGE W 9.9 15 15.6 15 16.8 DC OUTPUT 3.3V 3A 5V 3A 12V 1.3A 15V 1A 24V 0.7A SPECIFICATIONS MODEL PMA15F-3R3 PMA15F-5 PMA15F-12 PMA15F-15 PMA15F-24 VOLTAGE V AC85 - 264 1f (Refer to the Instruction Manual 1.1 and Derating) *3 ACIN 100V 0.30typ (Io=100%) 0.40typ (Io=100%) CURRENT A ACIN 200V 0.15typ (Io=100%) 0.20typ (Io=100%) FREQUENCY Hz 50 / 60 (47 - 440) INPUT ACIN 100V 66typ 70typ 74typ 76typ 76typ EFFICIENCY % ACIN 200V 67typ 74typ 78typ 79typ 79typ ACIN 100V 15typ (Io=100%) (At cold start) INRUSH CURRENT A ACIN 200V 30typ (Io=100%) (At cold start) LEAKAGE CURRENT mA 0.05/0.10max (ACIN 100V / 240V 60Hz, Io=100%, According to IEC60601-1) VOLTAGE V 3.3 5 12 15 24 CURRENT A 3.0 3.0 1.3 1.0 0.7 LINE REGULATION mV 20max 20max 48max 60max 96max LOAD REGULATION mV 40max 40max 100max 120max 150max 0 to +50C 80max 80max 120max 120max 120max RIPPLE mVp-p *1 -10 - 0C 140max 140max 160max 160max 160max 0 to +50C 120max 120max 150max 150max 150max RIPPLE NOISE mVp-p *1 OUTPUT -10 - 0C 160max 160max 180max 180max 180max 0 to +50C 50max 50max 120max 150max 240max TEMPERATURE REGULATION mV -10 to +50C 60max 60max 150max 180max 290max *2 DRIFT mV 20max 20max 48max 60max 96max START-UP TIME ms 200typ (ACIN 100V, Io=100%) *Start-up time is 700ms typ for less than 1minute of applying input again from turning off the input voltage. HOLD-UP TIME ms 20typ (ACIN 100V, Io=100%) OUTPUT VOLTAGE ADJUSTMENT RANGE V 2.85 to 3.60 4.50 to 5.50 10.00 to 13.20 13.20 to 18.00 19.20 to 27.00 OUTPUT VOLTAGE SETTING V 3.30 to 3.40 5.00 to 5.15 12.00 to 12.48 15.00 to 15.60 24.00 to 24.96 OVERCURRENT PROTECTION Works over 105% of rating and recovers automatically PROTECTION OVERVOLTAGE PROTECTION V 4.00 to 5.25 5.75 to 7.00 15.00 to 18.00 20.00 to 25.00 30.00 to 37.00 CIRCUIT AND OPERATING INDICATION LED (Green) OTHERS REMOTE ON/OFF Not provided INPUT-OUTPUT AC4,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) ISOLATION INPUT-FG AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) OUTPUT-FG AC500V 1minute, Cutoff current = 25mA, DC500V 50MW min (At Room Temperature) OPERATING TEMP.,HUMID.AND ALTITUDE -10 to +70C, 20 - 90%RH (Non condensing), 3,000m (10,000 feet) max *3 STORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000 feet) max ENVIRONMENT 2 VIBRATION 10 - 55Hz, 19.6m/s (2G), 3minutes period, 60minutes each along X, Y and Z axis 2 IMPACT 196.1m/s (20G), 11ms, once each X, Y and Z axis AGENCY APPROVALS UL60601-1, C-UL (CSA-C22.2 No.601.1), EN60601-1 SAFETY AND NOISE CONDUCTED NOISE Complies with FCC-B, VCCI-B, CISPR11-B, CISPR22-B, EN55011-B, EN55022-B REGULATIONS *6 HARMONIC ATTENUATOR Complies with IEC61000-3-2 (Class A) (Not built-in to active filter *4) CASE SIZE/WEIGHT 31X78X103mm 1.22X3.07X4.06 inches (WXHXD) / 230g max (with cover : 265g max) OTHERS COOLING METHOD Convection *1 Measured b y 20MHz oscilloscope or Ripple-Noise meter (equivalent to KEISOKU-GIKEN: RM101). *5 Please contact us about saf ety approvals for the model with option. *2 Dr ift is the change in DC output for an eight hour period after a half-hour warm-up at 25C. *6 Please contact us about another class. *3 Refer to Derating. * Parallel operation with other model is not possible. *4 When tw o or more units are used, they may not comply with the harmonic attenuator. Please * Der ating is required when operated with cover. contact us for details. * A sound ma y occur from power supply at peak loading. July 01, 2020 PMA-2