Ordering information
AC-DC Power Supplies Enclosed type
RMC 15A -1 -O
RMC15A
1234
1Series name
R
2Output wattage
3Output voltage combina-
tion
4Optional *2
C :with Coating
G :Low leakage current
J :Connector type
N :with Cover
RMC
MODEL RMC15A-1 RMC15A-2
V1 +5V 2.0A +5V 2.0A
DC OUTPUT V2 +12V 0.3A +15V 0.2A
V3 -12V 0.2A -15V 0.2A
SPECIFICATIONS
MODEL RMC15A-1 RMC15A-2
VOLTAGE[V] AC85 - 132 1 or DC110 - 170
f
( )
CURRENT[A] ACIN 100V 0.45typ Io=100%
INPUT FREQUENCY[Hz] 47 - 440 or DC
( )
EFFICIENCY[%] ACIN 100V 65typ Io=100%
( )( )
INRUSH CURRENT[A] ACIN 100V 20typ Io=100% At cold start
VOLTAGE[V] +5 +12 -12 +5 +15 -15
CURRENT[A] 0 - 2.0 0 - 0.3 0 - 0.2 0 - 2.0 0 - 0.2 0 - 0.2
LINE REGULATION[mV] 20max 48max 48max 20max 60max 60max
LOAD REGULATION[mV] 100max 120max 120max 100max 150max 150max
*1
0to+50 100max 120max 120max 100max 120max 120max
C
RIPPLE[mVp-p]
*1
-10-0 150max 160max 160max 150max 160max 160max
C
1
0to+50 * 120max 150max 150max 120max 150max 150max
C
OUTPUT RIPPLE NOISE[mVp-p]
*1
-10-0 170max 180max 180max 170max 180max 180max
C
0to+50 50max 350max 350max 50max 350max 350max
C
TEMPERATURE REGULATION[mV]
-10 to +50 60max 420max 420max 60max 420max 420max
C
( , )
START-UP TIME[ms] 100max ACIN 85V Io=100%
( , , ) ( , , )
HOLD-UP TIME[ms] 10typ ACIN 85V Io=100% 0to+50 20typ ACIN 100V Io=100% 0to+50
C C
OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 5.00 - 5.25 Fixed Fixed 5.00 - 5.25 Fixed Fixed
OUTPUT VOLTAGE SETTING[V] 11.40 to 12.60 -11.40 to -12.60 14.25 to 15.74 -14.25 to -15.75
xx xx
OVERCURRENT PROTECTION Works over 105% of rating and recovers automatically
PROTECTION
OVERVOLTAGE PROTECTION By zerer diode clamping (+5V only)
CIRCUIT
( )
OPERATING INDICATION LED Green
, , ( )
INPUT-OUTPUT AC2 000V 1minute DC500V 50M min At Room Temperature
W
INPUT-FG, COVER AC2,000V 1minute, DC500V 50M min (At Room Temperature)
W
ISOLATION
, , ( )
OUTPUT-FG COVER AC500V 1minute DC500V 50M min At Room Temperature
W
( , ) , ( )
OUTPUT-OUTPUT V1-V2 V3 AC100V 1minute DC100V 10M min At Room Temperature
W
OPERATING TEMP.,HUMID.AND ALTITUDE -10 to +60 , 20 - 90%RH (Non condensing)(Refer to DERATING CURVE), 3,000m (10,000feet) max
C
, , ( ), , ( , )
STORAGE TEMP. HUMID.AND ALTITUDE -20 to +75 20 - 90%RH Non condensing 9 000m 30 000feet max
C
ENVIRONMENT
2
, ( ), , ,
VIBRATION 10 - 55Hz 19.6m/s 2G 3minutes period 60minutes each along X Y and Z axis
2
IMPACT 196.1m/s (20G), 11ms, once each X, Y and Z axis
SAFETY AND
,
AGENCY APPROVALS UL60950-1 C-UL Complies with DEN-AN
NOISE
,
CONDUCTED NOISE Complies with FCC-B VCCI-B
REGULATIONS
CASE SIZE/WEIGHT 28 80 100mm (W H D) /250g max (without cover)
X X X X
OTHERS
COOLING METHOD Convection
*1 Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN : RM101).
*2 Please contact us about safety approvals for the model with option.
* Series/Parallel operation with other model is not possible.
* When units are operated with chassis and cover, derating is required.
RMC-2RMC15A
External view
RMC
Connector type Barrier strip type
Performance data
STATIC CHARACTERISTICS (RMC15A-1) RISE TIME & FALL TIME (RMC15A-1)
13.0 5.2 60
Output Voltage
-12V
+5V
12.0 5.0 50
+12V
11.0 4.8 40
Io=100%
10.0 4.6 30
9.0 4.4 20
Ripple
+5V
8.0 4.2 10
+12V
-12V
0
40 50 60 70 80 90 100 110 120 130
INPUT VOLTAGE V 60Hz
OVERCURRENT CHARACTERISTICS (RMC15A-1) DERATING CURVE
RMC-3
OUTPUT VOLTAGE V
RIPPLE mVp-p