. Ordering information AC-DC Power Supplies Bus Converter Power Module Value-added Type SNDPG 750 -O SNDPG750 1 2 3 1 Series name R 2 Output power 750 : 750W (ACIN 200V) 3 Optional C :with Coating R :with Remote ON/OFF (Enable signal) Please refer to Instruction manual 7. * Please note that the unit s internal components is damaged if the output is short-circuit. MODEL SNDPG750 AC INPUT V AC85 - 264 AC170 - 264 *1 500 750 MAX OUTPUT WATTAGE W *2 DC OUTPUT VOLTAGE V 360 SPECIFICATIONS MODEL SNDPG750 VOLTAGE V AC85 - 264 1f AC170 - 264 1f POWER FACTOR CORRECTION RANGE V AC85 - 264 1f CURRENT A 5.72typ (ACIN 100V) 4.24typ (ACIN 200V) FREQUENCY Hz 50/60 (47 - 63) INPUT AC100V 20/20 typ (Io=100%) (Primary inrush current / Secondary inrush current) (More than 10 sec. to re-start) INRUSH CURRENT A *3 AC200V 40/20 typ (Io=100%) (Primary inrush current / Secondary inrush current) (More than 10 sec. to re-start) EFFICIENCY % 93typ (ACIN 100V) 96typ (ACIN 200V) POWER FACTOR 0.96typ (ACIN 100V) 0.93typ (ACIN 200V) LEAKAGE CURRENT mA 0.75 max (60Hz, According to IEC60950 and DEN-AN) WATTAGE W 500 750 *2 OUTPUT VOLTAGE V 360 VOLTAGE ACCURACY *4 2% OVERVOLTAGE PROTECTION V DC400 - 450V The power factor corrector function stops PROTECTION SNDPG *5 CIRCUIT AND ENA Enable signal, Open-correcter output OTHERS OTHERS *6 Parallel operation impossible , Thermal protection *9 Non isolated INPUT-OUTPUT, RC *9 ISOLATION INPUT, OUTPUT, RC-FG AC2,800V 1minute Cutoff current = 10mA, DC500V, 50MW min (2015C) OUTPUT-RC *9 AC100V 1minute Cutoff current = 25mA, DC100V, 10MW min (2015C) *8 -20 to +95C(Aluminum base plate of the power module), 20 - 95%RH (Non condensing) (Refer to DERATING CURVE) 3,000m (10,000feet) max OPERATING TEMP.,HUMID.AND ALTITUDE STORAGE TEMP.,HUMID.AND ALTITUDE -20 to +95C, 20 - 95%RH (Non condensing), 9,000m (30,000feet) max ENVIRONMENT 2 VIBRATION 10 - 55Hz, 19.6m/s (2G), 3minutes period, 60minutes each along X, Y and Z axis 2 IMPACT 196.1m/s (20G), 11ms, once each along X, Y and Z axis SAFETY AGENCY APPROVALS UL60950-1, C-UL, EN60950-1, Complies with DEN-AN SAFETY CONDUCTED NOISE Complies with FCC-A, VCCI-A, CISPR22-A, EN55011-A, EN55022-A *7 Complies with IEC61000-3-2 HARMONIC ATTENUATOR CASE SIZE/WEIGHT 125X44.5X127mm 4.92X1.75X5.0inches (WXHXD) / 600g max OTHERS COOLING METHOD Conduction cooling (e.g. heat radiation from the aluminum base plate to the attached heat sink) *1 Refer to the instruction manual 2. *5 Refer to the instruction manual 4.4. *2 When the input voltage is more than 240V, the output voltage becomes the value *6 The thermal protection stops the power factor corrector function and the ENA signal. proportional to the input voltage. *7 Please contact us about class C. *3 The value is primary surge. The current of input surge to a built-in noise lter (0.2ms or less) *8 Refer to the instruction manual 6.2. is excluded. *9 Applicable when remote control (optional) is added. *4 The value included the output setting and the line regulation, the load regulation and the temperature regulation. However, the input voltage is less than 240V. SNDPG-2 SNDPG750 External view 10 0.39 Connector for remote ON/OFF (optional) 17.8 10 0.70 0.39 4-f0.177 4-f4.5 Terminal cover M4 8.6 Mounting hole 0.34 2 4 +Vout 1 2 CN2 -Vout TB1 1 FG AC AC ENA (N) (L) CN1 114.84 0.5 5.08 PointB PointA 0.20 4.520.02 125 4.92 Power module (DPG750) Tolerance : 1 0.04 Weight : 600g max Dimensions in mm, =inches PCB material/thickness : FR-4 / 1.6mm 0.06 Base plate material/thickness : Aluminum / 3.0mm 0.12 Screw tightening torque : 1.6N m (16.9kgf cm) max - - Name plate Base plate Component positions and sizes are for your reference if they have no dimensions. Please connect safety ground to the base plate in f4.5 f0.177 hole. Performance data STATIC CHARACTERISTICS (AC230V) OUTPUT VOLTAGE FOR INPUT 400 400 SNDPG750 SNDPG750 380 380 360 360 340 340 320 320 SNDPG 0 0 0 50 100 150 200 250 300 0 0.5 1.0 1.5 2.0 2.5 OUTPUT CURRENT A INPUT VOLTAGE V HARMONIC CURRENT (AC100V) HARMONIC CURRENT (AC230V) 10 10 SNDPG750 SNDPG750 Harmonic current standard Harmonic current standard of class A (at odd number) of class A (at odd number) 1 1 0.1 0.1 0.01 0.01 0.001 0.001 1 10 20 30 40 110 20 30 40 HARMONIC ORDER HARMONIC ORDER SNDPG-3 Powered by TCPDF (www.tcpdf.org) HARMONIC CURRENT OUTPUT VOLTAGE A V 116.84 0.5 5.08 0.20 4.600.02 44.5 max 8.6 1.75 max 0.34 HARMONIC CURRENT A OUTPUT VOLTAGE V 127 5.00