Ordering information AC-DC Power Supplies Open Frame/Enclosed Value-added Type SPLF A 30 F -O -O SPLFA30F 1 2 3 4 5 6 1 Series name 2 Single output 3 Output wattage 4 Universal input 5 Output voltage 6 Optional C : with Coating MODEL SPLFA30F-5 SPLFA30F-12 SPLFA30F-24 MAX OUTPUT WATTAGE W 30.0 30.0 31.2 DC OUTPUT 5V 6A 12V 2.5A 24V 1.3A SPECIFICATIONS MODEL SPLFA30F-5 SPLFA30F-12 SPLFA30F-24 *3 VOLTAGE V AC85 - 264 1f (Refer to Instruction Manual 1.1 and 3.1) ACIN 100V 0.65typ (Io=100%) CURRENT A ACIN 200V 0.35typ (Io=100%) FREQUENCY Hz 50 / 60 (47 - 440) INPUT ACIN 100V 75.0typ 78.0typ 81.0typ EFFICIENCY % ACIN 200V 77.0typ 80.0typ 83.0typ ACIN 100V 15typ (Io=100%) (At cold start) (Ta=25C) INRUSH CURRENT A ACIN 200V 30typ (Io=100%) (At cold start) (Ta=25C) LEAKAGE CURRENT mA 0.30 / 0.65max (ACIN 100V / 240V 60Hz, Io=100%, According to IEC60950-1 and DEN-AN) VOLTAGE V 5 12 24 CURRENT A 6.0 2.5 1.3 LINE REGULATION mV *5 20max 48max 96max *5 LOAD REGULATION mV 100max 100max 150max *1 0 to +50C 100max 120max 120max RIPPLE mVp-p *1 -10 - 0C 140max 160max 160max *1 0 to +50C 250max 250max 250max OUTPUT RIPPLE NOISE mVp-p *1 -10 - 0C 300max 300max 300max 0 to +50C 50max 120max 240max TEMPERATURE REGULATION mV -10 to +50C 60max 150max 290max *2 DRIFT mV 20max 48max 96max START-UP TIME ms 150typ (ACIN 100V, Io=100%) HOLD-UP TIME ms 20typ (ACIN 100V, Io=100%) OUTPUT VOLTAGE SETTING V 4.90 to 5.30 11.50 to 12.50 23.00 to 25.00 OVERCURRENT PROTECTION Works over 105% of rating and recovers automatically OVERVOLTAGE PROTECTION V 5.75 to 7.00 13.80 to 16.80 27.60 to 33.60 PROTECTION CIRCUIT AND OPERATING INDICATION LED (Green) OTHERS REMOTE SENSING Not provided REMOTE ON/OFF Not provided INPUT-OUTPUT AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) ISOLATION INPUT-FG AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) OUTPUT-FG AC500V 1minute, Cutoff current = 25mA, DC500V 50MW min (At Room Temperature) *3 OPERATING TEMP.,HUMID.AND ALTITUDE -10 to +60C, 20 - 90%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000feet) max STORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max ENVIRONMENT 2 VIBRATION 10 - 55Hz, 19.6m/s (2G), 3minutes period, 60minutes each along X, Y and Z axis 2 IMPACT 196.1m/s (20G), 11ms, once each X, Y and Z axis AGENCY APPROVALS DEN-AN SAFETY AND NOISE CONDUCTED NOISE/POWER Complies with DEN-AN REGULATIONS HARMONIC ATTENUATOR *4 Complies with IEC61000-3-2 class A (Not built-in to active filter) CASE SIZE/WEIGHT 61X36X150mm 2.40X1.42X5.91 inches (WXHXD) / 370g max OTHERS COOLING METHOD Convection *1 Measured by 20MHz oscilloscope or Ripple-Noise meter (Equivalent to KEISOKU-GIKEN: RM103). *2 Dr ift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output. *3 Derating is required. *4 When two or more units are operating it may not comply with the IEC61000-3-2. Please contact us about another class. *5 Please contact us about dynamic load and input response. * To meet the specifications. Do not operate over-loaded condition. * Parallel operation is not possible. * Derating is required when operated with chassis and cover. * Sound noise may be generated by power supply in case of pulse load. SPLFA-2 SPLFA30F Block diagram AC IN DC OUT LFA30F 85 - 264V External view Name plate 2-R1.75 150 2-R0.07 5.91 2-f0.14 2-f3.5 Terminal cover 0.5 1.5 M4 140 18 Mounting hole 5.51 0.71 -V Output terminal(-) Input +V Output terminal(+) AC(L) : Black AC(N) : White 100 2 450 15 LED 17.723.94 0.59 2-f0.14 2-f3.5 0.5 2-R1.75 140 2-R0.07 Mounting hole 5.51 Tolerance : 1 0.04 Weight : 370g max PCB material/thickness : CEM3 / 1.6mm 0.06 Chassis and cover material : Electric galvanizing steel board Dimensions in mm, =inches Mounting torque : M4 : 1.6N m (16.9kgf cm) max - - Input wire : VCTF 0.75sqX2C SPLFA-3 36 61 1.42 2.40 0.5 26 0.5 50 1.02 1.97 25.5 9.5 0.37 1.00 8.2 0.32