Ordering information AC-DC Power Supplies Enclosed type STA 5000 T -O STA5000T 1234 1Series name R 2Output wattage 3Triple input phase 4Optional *1 R :with Sequence unit STA *For connection of loads except the series DBS, please contact Cosel development department. *Never make a short-circuit between the output pins. It may severely damage the unit. SPECIFICATIONS MODEL STA5000T ( ) VOLTAGE V AC170 - 264 3 Rated input voltage : AC200V f ,( ) FREQUENCY Hz 50/60 47-63 INPUT INRUSH CURRENT A ACIN 200V 50typ ( ) POWER FACTOR 0.9typ ACIN 200V ( ) EFFICIENCY % 97.5typ ACIN 200V , WATTAGE W 5 000 OUTPUT ( ) OUTPUT VOLTAGE V DC230 - 370 Changes depending on the input voltage ( ) OPERATING INDICATION LED Green OVERCURRENT PROTECTION By means of fuse THERMAL PROTECTION Provided PROTECTION ( ) CIRCUIT AND REMOTE ON/OFF OUTPUT Provided Isolated from output OTHERS ( ) ALARM OUTPUT Provided Isolated from output ( , ) SYSTEM ON/OFF INPUT Provided Isolated from output optional ( , ) REMOTE SIGNAL ON/OFF OUTPUT Provided Isolated from output optional , , , ( ) INPUT-FG AC2 000V 1minute Cutoff current = 10mA DC500V 50M min At Room Temperature W , , , , ( ) ISOLATION INPUT-RS ON/OFF ALM AC2 000V 1minute Cutoff current=10mA DC500V 50M min At Room Temperature W , , , ( ) RS ON/OFF ALM-FG AC500V 1minute Cutoff current=50mA DC500V 50M min At Room Temperature W OPERATING TEMP -10-50 Forced air C STORAGE TEMP -20-75 C ENVIRONMENT 2 , ( ), , , VIBRATION 10 - 55Hz 19.6m/s 2G 3minutes period 60minutes each along X Y and Z axis 2 ( ), , , IMPACT 196.1m/s 20G 11ms once each X Y and Z axis SAFETY AND AGENCY APPROVALS UL60950-1, C-UL (CSA60950-1), EN60950-1 NOISE , , REGULATIONS CONDUCTED NOISE Complies with FCC-B CISPR22-classB EN55022-B *1 Please contact us about safety approvals for the model with option. STA-2STA5000T External view Terminal Block(M3) Mounting Hole(4-M4)Both Sides Terminal Block(M4) LED(Green) TB1 TB2 CN1CN2CN3CN4 CN5 CN6 CN7 CN8 CN9 0.5 18 25max 12 225 Name Plate 35 15 15 15 35 250 5max 131.5 Mounting torque: Weight:5kg or less 1.5N-m(16kgf-cm)max Tolerance 1 Dimensions in mm STA TB1 CN9 TB2(STA5000T-R) TYPE:B4B-XH TYPE:F2361A-13.2L-12P TYPE:F2331B 4P pin no. Function pin no. pin no. Function Function 1 REMOTE ON/OFF(+) 1 ALM(+) 1 AC(R) 2 REMOTE ON/OFF(-) 2 ALM(-) 2 AC(S) 3 AL OUT(+) 3 SYSTEM ON/OFF(+) 3 AC(T) 4 AL OUT(-) 4 SYSTEM ON/OFF(-) 4FG Mating Connector:XHP-4 5 R/S1 ON/OFF(+) CN1 - CN8 Terminal:SXH-001T-P0.6 6 R/S1 ON/OFF(-) TYPE:350825-1 or SXH-002T-P0.6 7 R/S2 ON/OFF(+) pin no. Function 8 R/S2 ON/OFF(-) 1 DC(+V) 9 R/S3 ON/OFF(+) 2 DC(-V) 10 R/S3 ON/OFF(-) 3FG 11 R/S4 ON/OFF(+) Mating Connector:350766-1 12 R/S4 ON/OFF(-) Terminal:350547-1 or 350552-1 Keep drawing current per pin bellow 8A of CN1 - CN8. Performance data SYSTEM CONCEPT Sample system configuration +S +VIN AC(R) +VOUT +V AC IN DBS Load RC1 3 AC(S) STA5000T -VIN -V -VOUT 200V AUX RC3 RC2 -S -S AC(T) REMOTE ON/OFF (+) REMOTE ON/OFF (-) +S +VIN +VOUT DBS Load RC1 -VIN -VOUT AUX RC3 RC2 -S -S STA-3 Powered by TCPDF (www.tcpdf.org) 144 58 45 65.5 0.5 104 20