True RMS AC Voltage Transducer The CR4500 Series, True RMS Voltage Transducers and DIN RAIL / PANEL MOUNT, TRUE RMS Transmitters are designed for applications where AC voltage waveforms are not purely sinusoidal. More precise and accurate than other devices, these units are ideal in chopped wave and phase fired control systems. Applications Phase fired controlled devices Quickly varying voltage supplies Chopped waveform drivers Harmonic voltages Features 35mm DIN rail mount or panel mount CR4510 CR4511 CR4520 Available with 0-5 VDC, 0-10VDC or 4-20 mADC output Single Element 24 VDC powered 1.0 to 600 VAC Input Range Highest precision available C Outputs isolated from inputs Connection diagram printed on case Regulatory Agencies Recognized to meet UL 61010B-1 Constructed to meet CAN/CSA-C22.2, No. 61010-1-2004 Meets requirement of IEC 61010-1 and BS EN 61010-1 CR4550 CR4560 CR4570 CR4580 E199795 Three Element 1.0 to 600 VAC Input Range Add suffix for input range 50 - 0-50 VAC PART NUMBERS 150 - 0-150 VAC CR4510 Single element with 0 - 5 VDC output - 250 - 0-250 VAC CR4511 Single element with 0 - 10 VDC output 500 - 0-500 VAC - Ranges available up to and CR4520 Single element with 4 - 20 mADC output - including 600 VAC CR4550 3-Phase 3-Wire with 0 to 5 VDC Output - CR4560 3-Phase 3-Wire with 4 - 20 mADC Output - * UL Recognized up to 300 Vac CR4570 3-Phase 4-Wire with 0 to 5 VDC Output - CR4580 3-Phase 4-Wire with 4 - 20 mADC Output - CR Magnetics has a wide selection of Potential Transformers to extend the range of any part. Contact factory for more information. The Professional Energy Monitoring Company 3500 Scarlet Oak Blvd. St. Louis MO USA 63122 V: 636-343-8518 F: 636-343-5119 M N TI Web: Transducers True RMS AC Voltage Transducer DIN RAIL / PANEL MOUNT, TRUE RMS SPECIFICATIONS Basic Accuracy:........................ 0.5% MTBF:......................... Greater than 100 K hours Linearity:................................ 10% to 100% FS Output Load:............... 4-20 mADC - 0 to 300 Calibration:............................... True RMS Sensing 0-5 VDC - 2K or Greater Thermal Drift:........................... 500 PPM/C Relative Humidity:......... 5% to 95%, Non-Condensing Operating Temperature:........... 0C to +60C Supply Current: Installation Category:............... CAT II CR4510:........................ Typical 15mA Max 25mA Vibration Tested To:................. IEC 60068-2-6,1995 CR4520:........................ Typical 25mA Max 40mA Pollution Degree:..................... 2 CR4550/70:................... Typical 20mA Max 60mA Response Time:....................... 250 ms CR4560/80:................... Typical 55mA Max 110mA Altitude:.................................... 2000 meter max. Torque Specs.:.............. 3.0 inch lbs. (0.4Nm) Insulation Voltage:.................... 2500 Vdc Weight:.......................... 0.5 lbs. Supply Voltage:........................ 24 Vdc 10% Frequency Range:................... 20 Hz - 5 KHz C Cleaning:.................................. Water-dampened cloth 1 - 1 + INPUT 1 2 9 OUTPUT INPUT 1 2 9 OUTPUT 1 3 8 3 8 4 7 4 26.6 7 + - +- 6 1.05 6 5 5 SUPPLY SUPPLY 3.3 DIN RAIL 73.1 .13 MOUNTING CR4510 Single Phase - 0 - 5 VDC Output CR4520 Single Phase - 4 - 20 mADC Output Optional 2.88 CLIP Mounting 83.3 CR4511 Single Phase - 0 - 10 VDC Output 3.28 Top View L1 L2 L3 L1 L2 L3 62.1 1 L3-L1 2.45 9 1 L3-L1 2 L2-L3 3 8 2 9 L2-L3 L1-L2 4 7 3 8 L1-L2 6 4 7 + - 30.4 28.3 5 6 5.6 + - 1.20 1.12 5 .22 SUPPLY TYP SUPPLY 36.6 88.7 End View 1.44 3.49 CR4560 3 Phase, 3 Wire - 4-20 mADC Output CR4550 3 Phase, 3 Wire - 0 - 5 VDC Output CR4510 CR4511 CR4520 End View L1 L2 L3 N 25 L1 L2 L3 N + - 1 .98 L3-N L3-N 2 1 9 L2-N + - 2 3 9 8 L2-N 4 3 L1-N 7 8 + - 4 7 6 L1-N 76.8 +- 6 5 + - 3.02 5 5.6 SUPPLY SUPPLY 28.3 .22 1.12 TYP CR4570 3 Phase, 4 Wire - 0 - 5 VDC Output CR4580 3 Phase, 4 Wire - 4 - 20 mADC Output 36.6 88.7 1.44 3.49 CR4550 CR4560 CR4570 CR4580 CONNECTION DIAGRAM OUTLINE DRAWING USE CR MAGNETICS LOW AND MEDIUM VOLTAGE POTENTIAL TRANSFORMERS (SECTION G) NOTE: The building installation must have a switch or circuit-breaker that is in close proximity and within easy reach of the operator. The switch or circuit breaker shall be marked as the disconnecting device for the equipment. The Professional Energy Monitoring Company 3500 Scarlet Oak Blvd. St. Louis MO USA 63122 V: 636-343-8518 F: 636-343-5119 M N TI Web: