Transducers Frequency Transducer DIN RAIL / PANEL MOUNT The CR6600 Series, Frequency Transducers and Transmitters are designed to give a DC output that is proportional to an input frequency value. These devices are especially suited to variable frequency systems. Applications Outputs isolated from inputs Ranges available for any application Sine, square and zero crossover waveforms 35 DIN rail or panel mount Connection diagram printed on case CR6610 CR6620 CR6611 CR6621 CR6612 CR6622 Features 40 - 5000 Hz Input Range 35mm DIN Rail or Panel Mount Available with 0 - 5 VDC, 0 - 10, or 4 - 20 mA DC output C 24 VDC powered Red LED Active Indication Highest precision available Connection diagram printed on case Regulatory Agencies Constructed to meet UL 61010B-1 Constructed to meet CAN/CSA-C22.2, No. 61010-1-2004 Meets requirement of IEC 61010-1 and BS EN 61010-1 E199795 Custom calibrations of unique full scale and zero scale values including parametric measurements are available. Contact factory for details. Add suffix for input range 100 - 0-100 Hz PART NUMBERS 500 - 0-500 Hz CR6610 Sine wave sensing with 0 - 5 VDC Output - 5000 - 0-5000 Hz CR6611 Square wave sensing with 0 - 5 VDC Output - other ranges available CR6612 Zero crossover sensing with 0 - 5 VDC Output - CR6620 Sine wave sensing with 4 - 20 mADC Output - CR6621 Square wave sensing with 4 - 20 mADC Output - CR6622 Zero crossover sensing with 4 - 20 mADC Output - The Professional Energy Monitoring Company 3500 Scarlet Oak Blvd. St. Louis MO USA 63122 V: 636-343-8518 F: 636-343-5119 M N TI Web: Frequency Transducer DIN RAIL / PANEL MOUNT SPECIFICATIONS Basic Accuracy:......................... 0.5% Output Load:................ 4-20 mADC -0 to 300 Linearity:.................................... 10% to 100% FS 0-5 VDC - 2K or Greater Thermal Drift:............................ 500 PPM/C Cleaning:.................... Water-dampened cloth Operating Temperature:............ 0C to +60C Relative Humidity:......... 5% to 95%, Non-Condensing Installation Category:................. CAT II Input Voltage:................ 20 to 250 V Peak, Vibration Tested To:................... IEC 60068-2-6,1995 (other voltage ranges available) Pollution Degree:........................2 Supply Current: Response Time: ....................... 250 ms max. 0-90% FS CR6610:....................... Typical 30mA Max 40mA Supply Voltage:......................... 24 VDC CR6620:....................... Typical 50mA Max 95mA MTBF:.......................................Greater than 100 K hours Torque Specs.:............. 3.0 inch lbs. (0.4Nm) Frequency Range:....................0 Hz - 2kHz, sine wave Weight:......................... 0.5 lbs. Insulation Voltage:.................... 2500 VDC Altitude:................................... 2000 meter max. C Red LED Indicator Top View Light 1 INPUT 1 2 9 OUTPUT 1 3 3.3 8 4 .13 7 +- Optional Din Rail 6 73.1 Mounting Mounting 5 2.88 Clip 83.3 SUPPLY 3.28 CR6610 0 - 5 VDC Output CR6611 0 - 5 VDC Output 62.1 2.45 CR6612 0 - 5 VDC Output 1 5.6 - + INPUT 1 2 .22 9 OUTPUT 3 8 4 7 + - 6 88.7 5 3.49 SUPPLY CR6610 CR6611 CR6612 CR6620 CR6621 CR6622 CR6620 4 - 20 mADC Output CR6621 4 - 20 mADC Output 32.4 30.4 28.3 1.3 1.2 1.12 CR6622 4 - 20 mADC Output 36.6 End View 1.44 OUTLINE DRAWING CONNECTION DIAGRAM NOTE: The building installation must have a switch or circuit-breaker that is in close proximity and within easy reach of the operator. The switch or circuit breaker shall be marked as the disconnecting device for the equipment. The Professional Energy Monitoring Company 3500 Scarlet Oak Blvd. St. Louis MO USA 63122 V: 636-343-8518 F: 636-343-5119 M N TI Web: