w w w.crouze-t switches.com 1 microswitches 07/2016 Miniature Mches - witosicr seaLeD V3S - 83169 High precision flexible leaf snap-action mechanism Operation without balance-point, even at extremely slow actuating speed Excellent resistance to har sh environments - IP67/IP69 protection High resistance to shock and vibration - Very long life Operating temperature -40 C up to 130 C Wire lead or cable output Tight switching hysteresis versions: 0.07 mm max differential travel Ratings from 1 mA 4 Vc to 8 A 250 Va and 1/4 HP 125-250 Va Wide choice of actuators on 4 possible fixing positions (pre-assembled or retrofittable) Main specifications Standard Reduced differential Dual-current Dual-current 831690 travel 831698 Reduced differential 831694 travel 831699 Function Connections I (changeover) D0.5 83169002 83169405 83169802 83169905 I (changeover) G0.5 83169001 83169404 83169801 83169904 I (changeover) C0.5 83169015 83169406 83169803 83169906 I (changeover) Y0.5 83169046 83169442 83169820 83169913 I (changeover) D - G - C - Y * R (normally closed) D - G - C - Y * C (normally open) D - G - C - Y * * wire length or cable length on demand Electrical characteristics Rating nominal / 250 V AC (A) 8 5 5** 5** Rating thermal / 250 V AC (A) 10 6 6 6 Mechanical characteristics Maximum operating force (N) 4.5 4.5 4.5 4.5 Min. Release force (N) 1 1 1 1 Maximum total travel force (N) 8 8 8 8 Max. Allowable overtravel force (N) 20 20 20 20 Rest position max. (mm) 15.9 15.9 15.9 15.9 0.5 0.5 0.5 0.5 Operating position (mm) 14.7 14.7 14.7 14.7 Maximum differential travel (mm) 0.35 0.07 0.35 0.07 Min. overtravel (mm) 1 0.4 1 0.4 Ambient operating temperature-wires (C) -40 +105 C -40 +105 C -40 +105 C -40 +105 C Ambient operating temperature-cable (C) -40 +90C -40 +90 C -40 +90 C -40 +90 C 6 6 6 6 Mechanical life (operations) 5 x 10 5 x 10 5 x 10 5 x 10 Contact gap (mm) 0.4 0.4 0.4 0.4 Weight (g) 30 30 30 30 Additional specifications - Case: PBT GF (UL 94-V0 / GWFI 960 C) - Degree of protection: IP67/IP69 - Button: stainless steel - Protection against electr ic shock : models with cable output on left are - Membrane: fluorosilicone rubber suitable for Class II equipment up to 250 V without additional protection - Moving blade: silver-plated beryllium copper - Recommended min actuating speed: 0.001 mm/s - Contacts: silver alloy, micro-profile gold alloy on silver alloy, crossbar (dual-current) - Wire leads, cable: copper, PVC insulated - Levers: stainless steel, polyamide roller Product adaptations Special levers: special shapes and lengths, flexible levers, adjustable, pinned, . Special leads and cables, EN 50306 halogen free versions, full wiring with custom connector High operating temperature: +130 C Long overtravel variant (min 3.5 mm) with metal or plastic plunger, also suitable for lateral approach up to 30 (SP4978, SP4988) Adjustab le fixing by threaded barrel: see 83581 Reinf orced housing with metal insert and cable output for very severe conditions Variant with plastic button for double insulation (SP4965) Integrated varistor for extended service life on DC inductive load cURus appr oved versions Standard product Product made to order Contact us w w w.crouze-t switches.com 2 microswitches 07/2016 Principles Single break snap-action switch Changeover - SPDT (form C) Normally closed - SPST-NC (form B) Normally open - SPST-NO (form A) V3S - 83169 2 2 1 11 11 High precision fle xible leaf snap-action mechanism 4 4 Operation without balance-point, even at extremely slow actuating speed Excellent resistance to harsh environments - IP67/IP69 protection High resistance to shock and vibration - Very long life Curves Operating temperature -40 C up to 130 C Wire lead or cable output Operating curve for type 831690 Operating curve for type 831694 Operating curve for types 831698/831699 Tight s witching hysteresis versions: 0.07 mm max differential travel Ratings fr om 1 mA 4 Vc to 8 A 250 Va and 1/4 HP 125-250 Va 1 2 1 2 3 3 L L 1 2 3 L = 5 ms = 5 ms = 5 ms Wide choice of actuators on 4 possible fixing positions (pre-assembled R R R ~ cos = 0,8 ~ cos = 0,8 7 ~ cos = 0,8 7 10 7 or retrofittable) 10 10 4 5 4 5 5 4 Main specifications 2 2 2 Standard Reduced differential Dual-current Dual-current 12Vc 12Vc 12Vc 6 6 10 6 10 831690 travel 831698 10 Reduced differential 250V~ 5 250V~ 5 5 250V~ 831694 travel 250V~ 250V~ 831699 2 2 2 Function Connections 5 5 10 5 10 10 B Number of cycles I (changeover) D0.5 83169002 83169405 83169802 83169905 5 5 5 C Resistive circuit I (changeover) G0.5 83169001 83169404 83169801 83169904 2 I (changeover) C0.5 2 D Inductive circuit 83169015 83169406 83169803 83169906 2 4 4 4 10 I (changeover) Y0.5 10 10 83169046 83169442 83169820 83169913 5 5 E Mechanical life limit 0.10.2 0.51 25 5 0.10.2 0.51 25 8 0.10.2 0.51 25 I (changeover) D - G - C - Y * F Current in Amps R (normally closed) D - G - C - Y * C (normally open) D - G - C - Y * ** Models 831698 and 831699 are designed to oper ate equally well on low-current (1 mA 4 V minimum recommended) or medium-current (5 A maximum) * wire length or cable length on demand circuits. However, a given product should only be used to switch one type of circuit during its working life. Electrical characteristics Rating nominal / 250 V AC (A) 8 5 5** 5** Dimensions Rating thermal / 250 V AC (A) 10 6 6 6 Mechanical characteristics Product Maximum operating force (N) 4.5 4.5 4.5 4.5 83169 Min. Release force (N) 1 1 1 1 Maximum total travel force (N) 8 8 8 8 Max. Allowable overtravel force (N) 20 20 20 20 Rest position max. (mm) 15.9 15.9 15.9 15.9 0.5 0.5 0.5 0.5 Operating position (mm) 14.7 14.7 14.7 14.7 Maximum differential travel (mm) 0.35 0.07 0.35 0.07 Min. overtravel (mm) 1 0.4 1 0.4 Ambient operating temperature-wires (C) -40 +105 C -40 +105 C -40 +105 C -40 +105 C Ambient operating temperature-cable (C) -40 +90C -40 +90 C -40 +90 C -40 +90 C 6 6 6 6 Mechanical life (operations) 5 x 10 5 x 10 5 x 10 5 x 10 Contact gap (mm) 0.4 0.4 0.4 0.4 Weight (g) 30 30 30 30 Additional specifications - Case: PBT GF (UL 94-V0 / GWFI 960 C) - Degree of protection: IP67/IP69 - Button: stainless steel - Protection against electr ic shock : models with cable output on left are - Membrane: fluorosilicone rubber suitable for Class II equipment up to 250 V without additional protection - Moving blade: silver-plated beryllium copper - Recommended min actuating speed: 0.001 mm/s - Contacts: silver alloy, micro-profile B Total travel position gold alloy on silver alloy, crossbar (dual-current) - Wire leads, cable: copper, PVC insulated Connections - Levers: stainless steel, polyamide roller D wire output on right G wire output on left C cable output on left Y cable output on right Product adaptations Special levers: special shapes and lengths, flexible levers, adjustable, pinned, . Special leads and cab les, EN 50306 halogen free versions, full wiring with custom connector High operating temperature: +130 C Long o vertravel variant (min 3.5 mm) with metal or plastic plunger, also suitable for lateral approach up to 30 (SP4978, SP4988) max. 5*** Adjustable fixing by threaded barrel: see 83581 Reinforced housing with metal insert and cable output for very severe conditions ***Outer jacket stripping Variant with plastic button for double insulation (SP4965) Integrated varistor for extended service life on DC inductive load Wire characteristics: Cable characteristics: 1: black (common) 1: black (common) cURus approved versions 2: brown (NC) 2: brown (NC) 4: blue (NO) 4: grey (NO) 2 2 Cross section: 1 mm Cross section: 3 x 0.75 or 2 x 0.75 mm Standard length: 0.5 m (other lengths on request) Standard length: 0.5 m (other lengths on request) 0,1 2 10,3 2 5 5