29/10/2013 www.crouzet.com
83139 Standard 831390 Part number Contact us
IP 67 protection against hydrocarbons, detergents
Double break switching
Double insulated or Atex flameproof casing
Choice of actuators
Part numbers
Function Connections
Type
CONTACT US Standard 831390 I (changeover) Cable output
Specifications
Electrical characteristics
Rating nominal / 250 VAC (A) 6
Rating thermal / 250 VAC (A) 11
Mechanical characteristics
Maximum operating force (N) 3
Min. Release force (N) 0,6
Maximum total travel force (N) 4
Max. permitted overtravel force (N) 10
Maximum rest position (mm) A= 8,8
B= 9,8
0.4
Operating position depending on position of fixing holes
A = 7.7
(mm) 0.4
B = 8.7
Maximum differential travel (mm) 0,35 0,1
Min. overtravel (mm) 0,25
Ambient operating temperature (C) 0+85
7
Mechanical life (operations)
10
Contact gap (mm) 0,3 x 2
Weight (g) 37
Fixations
Fixings - 4 holes (standard) A
Fixing - 2 holes B
Connections
Connection 4 flexible leads
2
0.75 mm length 0.50 m
ext. 2.3 mm
Standard wire output S
Wire output on right D
Wire output on left G
Additional specifications
Components
Material
- Case: polyester UL94V0
- Contacts: silver
- Membrane: nitrile for 831390 silicon for 831391/2/5
Levers
- stainless steel
- Roller: polyamide
Principles
Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected29/10/2013 www.crouzet.com
Dimensions (mm)
Product
831390 - 5
A fixing = 4 holes
o
N Legend
R: 1.5 spherical
Lead reference on casing
Lead output on left
Lead output on right
Standard lead output (black)
1 = black lead
2 = brown lead
3 = grey lead
4 = blue lead
Dimensions (mm)
Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected