02/11/2015 www.crouzet.com PBX Secure Low level83241 Part number made to order Dimensions according to standard DIN 41636 type F Positive break operation mechanism according to IEC 60947-5-1 Annex K Double break changeover switch with electrically separated circuits (form Zb) IP 40 or IP 67 / IP 65 versions Operating temperature between -50 and +85C Long overtravel Standard or Low level version Part numbers Type Degree of protection mechanism - connection Connections / Accessories 83241034 Low level83241 IP 40 - IP 20 W5 + Protective cover + Lever + Mounting plate with holes Specifications Electrical characteristics Direct opening action Rating nominal / 250 VAC (A) - Rating nominal / 250 VDC (A) - Rating thermal (A) - Operatingrange/430VDC/AC(A) 0,0010,1 Mechanical characteristics Minimum operating force (Nm) 4,5 Minimum positive opening force (N) 28 Maximum rest position (mm) 8,9 0.25 Operating position (mm) 6,6 * Positive opening position (mm) 4,4 * Maximum end of travel position (mm) 3,4 * 0,3 Differential travel (mm) 1 Operating temperature (C) -50+85 7 Mechanical life (operations) 10 (IP40) 6 4 x 10 (IP67) Contact gap (mm) 2 x 1 Max. tightening torque (Nm) 1.3 on 4.1 holes Weight (g) 22 * Comments * Values given for versions without lever (in relation to the reference dimension X0 - See Dimensions section). Additional characteristics Components Material - Case/cover: PC GF 20 FR. (UL 94-V0, GWFI 960C, NFF 16-101/102 I2F1) - Contacts: AgNi for Standard version and AgPd for low level version - Terminals: Brass - Button membrane: Silicone - Screws: zinc protected steel (stainless steel on request) Conformity to standards - Construction and performance according to IEC 60947-5-1 - Positive opening operation according to IEC 60947-5-1 Annex K - Dimensions conforming to standard DIN 41636 type F - Insulation characteristics according to standard IEC 60947-5-1 * Impulse withstand voltage: Uimp = 4 KV * Rated insulation voltage: Ui = 400 V * Pollution degree = 3 - Insulation characteristics according to standard EN 50124-1 * Impulse withstand voltage: Uimp = 2.5 KV * Rated insulation voltage: Ui = 150 V * Pollution degree = PD3A Principles Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected02/11/2015 www.crouzet.com Function Four-terminal two-way snap-action contact element (form Zb) with positive break operation. The 2 contacts are electrically separated. Dimensions (mm) Product 83240 - 83241 - 83242 - 83243 o N Legend Fixing screw threaded length Fixing nuts 2 x M3 Dimensions (mm) Connections W3 for 6.35 mm x 0,8 mm female connector Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected