Compact limit switch conforming to NFC 63 145 Series 83 880 with cable output IP 66/67 Metal case cUL approval Main specifications Metal plunger Characteristics Type of output Standard Cable length 1 m 83 880 101 Standard Cable length 2 m 83 880 102 Standard Cable length 3 m 83 880 103 Standard Cable length 6 m 83 880 106 Plunger with 90 roller Cable length 1 m - Plunger with 90 roller Cable length 2 m - Plunger with 90 roller Cable length 3 m - Plunger with 90 roller Cable length 6 m - Mechanical characteristics Sequence BK-BK Snap action BN-BU BK-BK BN-BU PRP PA POP PFC 18,4 mm 16,6mm 14,4mm13,3mm CD 1,1 mm Minimum operating force (N) 10 Minimum operating force (Nm) - Minimum total travel force (N) 30 Minimum total travel force (Nm) - Min. positive opening travel (N) 28 Min. positive opening travel (Nm) - Mechanical life millions of operations 10 Vertical approach speed 1 mm/min 0.5 m/s Horizontal approach speed (30 cam) - Weight (g) 190 General characteristics Assigned impulse voltage (Uimp) - V 2500 Assigned insulation voltage (Ui) V 500 Thermal current (Ith) A 10 Low-load switching - Minimum voltage (V) 10 Low-load switching - Minimum current (mA) 100 Assigned working characteristics (EN 60 947.5.1, UL 508) A300 = AC15 250 V 6 A Q150 = DC13 24 V 8 A Use category according to IEC 947.5.1 AC15=250 V/6 A DC13=24 V/8 A Use category according to UL 508 A300 - Q150 Electrical protection Integral earth wire Short-circuit protection device : IEC/EN 60947.5.1 Fuse 6 AgC Approvals UL 508, UL 50 Product adaptations Contact type Rear output Protective scraper seal Length of cable/connector/stripping Connector output Low level contactMetal roller plunger Metal plunger with Roller plunger - metal Steel metal roller lever threaded barrel with threaded barrel (2 directions of attack) 83 881 101 83 884 101 83 882 101 83 883 101 83 881 102 83 884 102 83 882 102 83 883 102 83 881 103 83 884 103 83 882 103 83 883 103 83 881 106 83 884 106 83 882 106 83 883 106 83 885 101 - 83 886 101 - 83 885 102 - 83 886 102 - 83 885 103 - 83 886 103 - 83 885 106 - 83 886 106 - BK-BK BK-BK BK-BK BK-BK BN-BU BN-BU BN-BU BN-BU BK-BK BK-BK BK-BK BK-BK BN-BU BN-BU BN-BU BN-BU PRP PA POP PFC PRP PA POP PFC PRP PA POP PFC PRP PA POP PFC 33,4mm 31,6mm 29,4mm 28,3mm 30,3 mm 28,4mm 26,15mm 25,15mm 43,6 mm 41,7mm 39,45mm 38,45mm 0 27 58 69 CD 1,1 mm CD 1,1 mm CD 1,1 mm CD 14 10 10 10 - -- -0.15 30 30 30 - -- -0.35 28 28 28 - -- -0.15 10 10 10 10 1 mm/min 0.5 m/s - 1 mm/min 0.5 m/s 1 mm/min 0.5 m/s 1 mm/min 0.3 m/s 1 mm/min 0.3 m/s 1 mm/min 0.3 m/s - 200 220 220 230 Principles Function Four-terminal double break two-way contact element (form Zb) with positive opening NC contacts. The 2 moving contacts are electrically isolated from one another. Snap-action contact 1 2 BN BK Zb BU BK GN-YW 3 2 4 B Brown C Black D Blue E Green-yellow