Panel Mount
Datasheet
GN Series
AC Output SSRs
Current rating 10 and 125 Amps
Output voltage 24-280 VAC and 48-660 VAC
Available with or without IP20 touch-safe cover
LED Input Status Indicator
UL Approved, CE Compliant to EN60950-1
Improved SEMS screw and washer
Redesigned housing with anti-rotation barriers
EMC Compliant to level 3
For Generation 3 datasheet click here
PRODUCT SELECTION
Control Voltage 10 A 25 A 50 A 75 A 100 A 125 A
3-32 VDC 84134000 84134010 84134020 84134030 84134040 84134080
18-36 VAC 84134002 84134012 84134022 84134032 84134042 84134082
90-280 VAC 84134001 84134011 84134021 84134031 84134041 84134081
Operating Voltage
AVAILABLE OPTIONS 0: 24-280 VAC/Zero Voltage Turn-On
1: 48-660 VAC/Zero Voltage Turn-On
2: 24-280 VAC/Instantaneous Turn-On
3: 48-660 VAC/Instantaneous Turn-On
Thermal Pad
Blank: Not included
Series
H: Included
8413 4 0 1 U0 H
Control Voltage
Rated Load
Touch Safe Cover
0: 3-32 VDC
Current
4: Not included (IP00)
Required for valid part number 0: 10 Amps 1: 90-280 VAC
7: Included (IP20)
For options only and not required for valid part number 2: 18-36 VAC
1: 25 Amps
2: 50 Amps
Not all part number combinations are available.
>
3: 75 Amps
Contact Crydom Technical Support for information on
4: 100 Amps
the availability of a specific part number.
8: 125 Amps
(1)
OUTPUT SPECIFICATIONS
Description 280 VAC 660 VAC
Operating Voltage (47-440Hz) [Vrms] 24-280 48-660
Transient Voltage [Vpk] (2) 600 1200
Maximum Off-State Leakage Current @ Rated Voltage [mArms] 0.1 0.25
Minimum Off-State dv/dt @ Maximum Rated Voltage [V/sec] 500 500
(1)
OUTPUT SPECIFICATIONS
Description 10 A 25 A 50 A 75 A 100 A 125 A
Maximum Load Current [Arms] (3) 10 25 50 75 100 125
Minimum Load Current [mArms] 500 50 100 100 100 100
Maximum 1 Cycle Surge Current (50/60Hz) [Apk] 150/175 275/300 710/750 1050/1100 1120/1200 1600/1700
1 Second surge current (Apk. Ta=25C) 50/60 Hz 50 85 150 225 300 375
Maximum On-State Voltage Drop @ Rated Current [Vpk] 1.35 1.35 1.35 1.3 1.3 1.25
Thermal Resistance Junction to Case (Rjc) [C/W] 0.4 0.4 0.25 0.16 0.16 0.11
Maximum 1/2 Cycle I t for Fusing (50/60Hz) [A sec] 110/120 380/370 2520/2320 5500/5000 6270/6000 12800/12050
Minimum Heat Sink for Rated Current @ 40C [C/W] 5 2 1 0.7 0.5 0.5
Do not forget to visit us at: www.crydom.com
Copyright 2016 Crydom Inc. Specifications subject to change without notice.Panel Mount
Datasheet
(1)
INPUT SPECIFICATIONS
Description 8413xxx0 8413xxx2 8413xxx1
Control Voltage Range 3-32 VDC (4) 18-36 VAC 90-280 VAC (5)
Maximum Reverse Voltage -32 VDC - -
Minimum Turn-On Voltage 3 VDC (4) 18 VAC 90 VAC
Must Turn-Off Voltage 1 VDC 4 VAC 10 VAC
Minimum Input Current (for on-state) [mA] 10 13 6
Maximum Input Current [mA] 15 15 10
Nominal Input Impedance [Ohms] Current Regulated
Maximum Turn-On Time [msec] 1/2 Cycle (6) 20 20
Maximum Turn-Off Time [msec] 1/2 Cycle 30 30
(1)
GENERAL SPECIFICATIONS
Description Parameters
Dielectric Strength, Input/Output/Base (50/60Hz) 4000 Vrms
9
Minimum Insulation Resistance (@ 500 VDC)
10 Ohms
Maximum Capacitance, Input/Output 8 pF
Ambient Operating Temperature Range (7) -40 to 80 C
Ambient Storage Temperature Range -40 to 125 C
Weight (typical) 2.53 oz (72 g)
Housing Material UL94 V-0
Baseplate Material Aluminum
Input Terminal Screw Torque Range (in-lb/Nm) 13-15 /1.5-1.7
Load Terminal Screw Torque Range (in-lb/Nm) 18-20 / 2-2.2
SSR Mounting Screw Torque Range (in-lb/Nm) 18-20 / 2-2.2
Humidity per IEC60068-2-78 93% non-condensing
LED Input Status Indicator Green
11,641,553 hours (1,328 years)
MTBF (Mean Time Between Failures) at 40C ambient temperature (8)
7,210,376 hours (823 years)
MTBF (Mean Time Between Failures) at 60C ambient temperature (8)
GENERAL NOTES
(1) All parameters at 25C unless otherwise specied.
(2) Output will self trigger between 450-600 Vpk / 900-1200 Vpk for 280 VAC/660 VAC models not suitable for capacitive loads.
(3) Heat sinking required, see derating curves.
(4) 4-32 VDC for 48-660 VAC models.
(5) For ambient temperatures above 40C the maximum control voltage must not exceed 250 VAC.
(6) Turn-on time for Instantaneous turn-on versions is 0.1 msec.
(7) AC models operating range is -20 to 80C.
(8) All parameters at 50% power rating and 100% duty cycle (contact Crydom tech support for detailed report).
(9) Load can be wired to either SSR output terminal 1 or 2.
(10) For single surge pulse Tc=25C; Tj=125C. For AC Output SSRs, AC Rms value of surge current equals the peak value divided by 2 (1.414).
For additional information or specic questions, contact Crydom Technical Support.
Do not forget to visit us at: www.crydom.com
Copyright 2016 Crydom Inc. Specifications subject to change without notice.