DIN Rail Mount
Datasheet
GNR 22.5mm Series
Current ratings of 10, 20 and 30 amps
Output voltage ratings: 24-280 and 48-600 VAC
Direct Bond Copper (DBC) Substrate
LED input status indicator
UL 508 Endurance Rating for Enhanced Reliability
UL/CSA Approved, CE Compliant
Built-in overvoltage protection
DIN Rail or Panel Mount
Zero voltage or Instantaneous turn-on output
PRODUCT SELECTION
Control Voltage 10A 20A 30A
4-32 VDC GNR10DHZ GNR20DHZ GNR30DHZ
90-140 VAC GNR10BHZ GNR20BHZ GNR30BHZ
180-280 VAC GNR10AHZ GNR20AHZ GNR30AHZ
AVAILABLE OPTIONS
Operating Voltage
Switching Type
A: 180-260 VAC
R: Instantaneous Turn-on
B: 90-140 VAC
(for DC control only)
Series D: 4-32 VDC
Z: Zero voltage Turn-on
GNR 10 A H Z
Terminal Layout
Rated Load Current
C: Contactor configuration
10: 10 Amps
H: Relay configuration
20: 20 Amps
30: 30 Amps
Required for valid part number
For options only and not required for valid part number
(1)
OUTPUT SPECIFICATIONS
Description GNR10 GNR20 GNR30
Operating Voltage (47-440Hz) [Vrms] 24-280 48-600 48-600
Transient Overvoltage [Vpk, t=1 min.] 600 1100 1100
Maximum Off-State Leakage Current @ Rated Voltage [mArms] 0.1 0.1 0.1
500 500 500
Static Off-State dv/dt ( V/sec, Ta=25C) (2)
Maximum Load Current [Arms] 10 20 30
100 100 100
Minimum Load Current [mArms]
190/200 286/300 716/750
Maximum Surge Current (50/60 Hz, 1 cycle) [Apk]
65 85 150
1 Second Surge Current (Apk Ta=25C) 50/60 Hz
1.5 1.35 1.35
Forward Voltage Drop (Vpk @ max, Ta=25C)
182/166 410/374 2562/2334
Maximum I t for Fusing (50/60Hz, 1/2 cycle ) [A sec]
- 1.2/9.8 3/4 / 13.8
HP Ratings at 120V / FLC [Arms]
- 1/8 2/12
HP Ratings at 240V / FLC [Arms]
16/8 AWG 16/8 AWG 16/8 AWG
Min/Max stranded wire
16/10 AWG 16/10 AWG 16/10 AWG
Min/Max solid wire
FDE-07-01 REV. A
Do not forget to visit us at: www.crydom.com
Copyright 2018 Crydom Inc. Specifications subject to change without notice.DIN Rail Mount
Datasheet
(1)
INPUT SPECIFICATIONS
Description GNRxxDx GNRxxBx GNRxxAx
Control Voltage Range (3) 4.0-32 VDC 90-140 Vrms 180-280 Vrms
Minimum Turn-On Voltage 4.0 VDC 90 Vrms 180 Vrms
Must Turn-Off Voltage 1.0 VDC 10 Vrms 10 Vrms
Minimum Input Current (for on-state) 6 mA 5 mArms 6 mA
Maximum Input Current
10 mA 23 mArms 2 mA
Input Resistance
Current Regulated Current Regulated Current Regulated
Maximum Turn-Off Time [msec]
1/2 Cycle 20 20
Maximum Turn-On Time [msec] (4)
1/2 Cycle 30 30
Min/Max stranded/solid wire 24/16 AWG 24/16 AWG 24/16 AWG
(1)
GENERAL SPECIFICATIONS
Description Parameters
Ambient Operating Temperature Range (3)
-20 to 80C
Ambient Storage Temperature Range
-40 to 100 C
4000 Vrms
Dielectric Strength, Input to Output (50/60Hz)
Dielectric Strength, Input/Output to Ground (50/60Hz) 2500 Vrms
Maximum Capacitance, Input/Output 8 pF
Housing Material
UL 94V0 (self extinguishing)
Input Status Indicator
Green LED
Weight (typical) 7.94 oz (225g)
GENERAL NOTES
(1) All parameters at 25C unless otherwise specied.
(2) Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1
(3) For 180-280 VAC Control. Maximum Ambient operating temperatures is 60C.
(4) Turn-on time for Instantaneous version (R sufx) is 0.1 msec (for DC control only).
For additional information or specic questions, contact Crydom Technical Support.
(1)
MECHANICAL SPECIFICATIONS
Tolerances: 0.02 in / 0.5 mm
All dimensions are in: inches [millimeters]
Contactor Configuration
0.87
[22.5]
0.68
4.75
[17.3]
[120.8]
0.21
0.18
[5.3]
[4.5] DIA.
3.47
3.54
3.85
[88.2]
3.54
[89.8]
[97.8]
[89.8]
0.21
[5.3] DIA.
0.19
0.18
[4.6] [4.8] 0.70
[17.8]
Do not forget to visit us at: www.crydom.com
Copyright 2018 Crydom Inc. Specifications subject to change without notice.