GNR 22.5MM Series
Current ratings 10, 20 and 30 amps
Output voltage 24-280 and 48-600 VAC
Direct Bond Copper (DBC) Substrate
LED input status indicator
100K cycle UL508 Endurance Rating
UL / CSA / TUV Approved, CE Compliant
EMC Compliant Level 3
DIN-RAIL or Panel Mount
Zero-Crossing or Random Turn-on
PRODUCT SELECTION
Control Voltage 10A 20A 30A
4-32 VDC GNR10DHZ GNR20DHZ GNR30DHZ
90-140 VAC GNR10BHZ GNR20BHZ GNR30BHZ
180-280 VAC GNR10AHZ GNR20AHZ GNR30AHZ
AVAILABLE OPTIONS
OUTPUT SPECIFICATIONS (Voltage) (1)
Description GNR10 GNR20/30
Operating Voltage (47-440Hz) [Vrms] 24-280 48-600
Transient Overvoltage [Vpk, t = 1 min.] 600 1100
Maximum Off-State Leakage Current @ Rated Voltage [mArms] 0.1 0.1
Static off-state dv/dt (Vs, Ta =25C) (2) 500 500
OUTPUT SPECIFICATIONS (Current) (1)
Description GNR10x GNR20x GNR30x
Maximum Load Current [Arms] 10A 20A 30A
Minimum Load Current [mArms] 100 100 100
1 cycle surge current (50Hz) 190 286 716
1 cycle surge current (60Hz) 200 300 750
1 second surge current (Apk. Ta = 25C) 50/60 Hz 65 85 150
Forward Voltage Drop (Vpk @ Imax, Ta = 25C) 1.5 1.35 1.35
IT (50Hz, 1/2 cycle) 182 410 2562
IT (60Hz, 1/2 cycle) 166 374 2334
HP Ratings at 120V / FLC NA 1/2 / 9.8A 3/4 / 13.8A
HP Ratings at 240V / FLC NA 1 / 8A 2 / 12A
Min/Max stranded wire 16/8 AWG 16/8 AWG 16/8 AWG
Min/Max solid wire 16/10 AWG 16/10 AWG 16/10 AWG
INPUT SPECIFICATIONS (1)
Description GNRxxDx GNRxxBx GNRxxAx
Input Voltage Range (3) 4-32 VDC 90-140VAC 180-280VAC
Minimum Turn-On Voltage 4.0 VDC 90 Vrms 180Vrms
Drop out Voltage 1.0 VDC 10 Vrms 10 Vrms
Maximum Input Current 19mA 23mArms 23mArms
Minimum input current (for on-state) 16mA 6mArms 8mArms
Input Resistance Current Regulated Current Regulated Current Regulated
Turn-on time (4) 8.33ms 20ms 20ms
Turn-off time 8.33ms 30ms 30ms
Min/Max stranded/solid wire 24/16AWG 24/16AWG 24/16AWG
GENERAL SPECIFICATIONS
Description Parameters
Ambient Operating Temperature Range (3) -20 to 80 C
Ambient Storage Temperature Range -40 to 100 C
Input to output isolation 4000 Vrms
Input/output to ground isolation 2500 Vrms
Input to output capacitance 8 pF
Housing Material UL 94V0 (self extinguishing)
Status Indicating Display Green LED
Weight (typical) 0.5lbs (225 g)
GENERAL NOTES
1) All parameters at 25C unless otherwise specifie d.
2) Off-State dv/dt test method per EIA/NARM standard RS-433, paragraph 13.11.1
3) For 180-280VAC control, maximum Ambient operating temperature is 60C
4) Random turn-on time R suffix is 100s (for DC control only).