CONTROLS CONTROLS UR SERIES VOLTAGE CONTROL RELAY UL listed CSA recognized AC or DC Voltage Control Manual or Automatic Operation Adjustable Threshold 5 to 50% Hysteresis Range LED Relay Status Indicator 1. AC/DC voltage control without latching: 2 The output relay is energized when the voltage (AC peak voltage) S1 hysteresis exceeds the selected threshold. It de-energizes when the voltage Automatic Threshold falls below the hysteresis setting (5 to 50%) or when supply breaks. Unlatching The hysteresis is controlled by a potentiometer and its selection does R not change the chosen threshold. 2. AC/DC voltage control with latching: The output relay is energized when the voltage reaches the selected S1 threshold and stays latched in this position. The contact between ter- minal B1 and M (or 8 or 9) should be opened or the input power of S2 the device interrupted to reset. Manual Threshold Unlatching hysteresis SPECIFICATIONS: R Input 24 VDC, 24, 48, 110, 220 VAC 15%, 50/60 Hz Power consumption . 24 VAC: 1 VA 48 VAC: 1.2 VA 110 VAC: 3.5 VA 220 VAC: 7 VA Control Input Acceptance load (input) Range Resistance Permanent Less than WIRING DIAGRAM: AC or DC (max) 10ms peak max. 0.1 to 10 V 10 k 50 V 100 V DUR LUR 0.4 to 40 V 40 k 100 V 300 V + 4 to 400 V 400 k 440 V 750 V (+)0.1 to 10v (+)0.1 to 10v S1 S1 Hysteresis selection . 5 to 50% of set point (+)0.4 to 40v (+)0.4 to 40v (+)4 to 400v (+)4 to 400v Repeat accuracy 2% at a constant ambient (-)0v Output Relay . SPDT Relay Contact material AgCdO 6 5 7 A1 11 E1 E2 E3 Latching S2 4 Maximum loading . 10 A AC resistive 8 A DC inductive 8 Maximum switching voltage . 250 VAC 250 VDC 3 9 R Relay maximum power rating 2200 VA 2 10 1 11 12 14 B1 M A2 Transient protection . 2500 volts 30 W 6 Mechanical life of relay . 30 x 10 operations Latching (-)0v 5 Electrical life of relay . 2 x 10 at 2400 VA resistive load S2 Repetition accuracy . 0.5% at a constant ambient Response time 100 ms on make - 200 ms on break Operating temperature . -4F to +140F -20C to +60C Weight 7 oz. (200g) Option: 24 VDC power the voltage and the measured current must be from separate sources. D UR 24A ORDERING INFORMATION: MOUNTING SERIES INPUT POWER MOUNTING INPUT POWER SERIES D = DIN-rail mounting 24A = 24VAC UR L = 11 pin plug-in 24D = 24VDC UR SP50 48A = 48VAC 110A = 110VAC 220A = 220VAC Products and specifications subject to change without notice. Order/Technical Support Tel: (800) 677-5311 / FAX: (800) 677-3865 / www.crouzet-usa.com 2/93CONTROLS CONTROLS SR SERIES UNDER VOLTAGE RELAY UL listed CSA recognized Multiple AC/DC Voltages 5 to 20% Hysteresis Adjustment Automatic Operation Adjustable Threshold The voltage threshold SR Relay controls a voltage supply which is its own supply. The output relay is energized when the supply Threshold (effective for AC) exceeds the selected threshold. It de-energizes hysteresis when the controlled supply falls below (5 to 20% Hysteresis) of the supply voltage or when the input power breaks. Hysteresis R is controlled by a potentiometer and its selection does not change the chosen threshold. Pulses or drops of 100ms or 0 t less are ignored. SPECIFICATIONS: Input 12 VDC, 24 VAC, 24 VDC, 48 VAC 48 VDC, 110 VAC, 220 VAC, 50/60 Hz -20% to +30% DC, -30% to +15% AC DSR PSR LSR Maximum power consumption .24 VAC: 1.5 VA 24 VDC: .6 W 48 VAC: 2 VA 24 VDC: .8 W + 110 VAC: 5 VA 48 VDC: 1.8 W S S S 220 VAC: 11 VA Residual ripple .<Hysteresis value Output relay SPDT Relay Contact material AgCdO 6 A1 11 45 5 7 Maximum loading .10 A AC resistive 8 A DC inductive 4 8 3 6 Maximum switching voltage .250 VAC 250 VDC R 3 9 Maximum power rating .2200 VA 80 W RR 2 7 6 10 Mechanical life of relay .30 x 10 operations 2 A2 12 14 1 11 1 8 5 Electrical life of relay .2 x 10 at 2200 VA resistive load Operating temperature .+14F to 140F -10C to +60C Weight 2.8 oz. (100g) ORDERING INFORMATION: L SR 24 MOUNTING SERIES INPUT POWER SERIES INPUT POWER MOUNTING SR 12 = 12 VDC D = DIN-rail or panel mounting 24D = 24 VDC L = 11 pin plug-in 24A = 24 VAC P = 8 pin plug-in 48D = 48 VDC 48A = 48 VAC 110 = 110 VAC 220 = 220 VAC Products and specifications subject to change without notice. Order/Technical Support Tel: (800) 677-5311 / FAX: (800) 677-3865 / www.crouzet-usa.com 2/94