11/2018 Plug-In Timer 8 pins Multifunction or monofunction Compact body for space saving Wide time range (from 0.5 seconds to 10 days delay) Universal power supply (12-240 Vz) 1 or 2 relay outputs (SPDT / Changeover) OU1R10MV1 OA2R10MV1 OC1R10MV1 OL1R10MV1 Multifunction U - Monofunction A Monofunction C Monofunction L - Li Protective cover Monofunction Ad - N LED status indicator 3-wire PNP sensor compatible 8-pins connections Product selection Function Output Supply Voltage Part Number Multifuntion U: (A, At, B, C, H, Ht, 1 relay 12 to 240 Vz OU1R10MV1 D, Di, Ac, Bw) Ad - N A 2 relays 12 to 240 Vz OA2R10MV1 C 1 relay 12 to 240 Vz OC1R10MV1 L - Li 1 relay 12 to 240 Vz OL1R10MV1 PART NUMBERING SYSTEM Type Output Quantity Output Power O: Plug-in 8-Pins 1: 1 Output 10: 10 A 2: 2 Outputs P: Plug-in 11-Pins O1A R 10 MV1 Function Output Type Power Supply A: ON-Delay R: Relay MV1: 12-240V AC/DC C: OFF-Delay L: Repeat Cycle U: Multifuction U You have a project Contact us on www.crouzet.com Description: Syr-line, the new specialized range at Crouzet, aimed to satisfy the most unique requirements of your applications by innovating in design, engineering and development. The Plug in Analog Timers, a new family of 8 timers with multifuction or monofunction, universal power supply, wide time range, with all the classic functions. For more information about Crouzets Syr-line range, please visit www.crouzet.com. AUTOMATION.CROUZET.COM 2 Plug-In Timer 11/2018 OU1R10MV1 OA2R10MV1 OC1R10MV1 OL1R10MV1 Power Supply Rated supply voltage Un 12 to 240 Vz Voltage supply tolerance -15 %, +10 % AC supply voltage frequency 50 / 60 Hz 5% Galvanic isolation of supply / inputs No Power consumption Un Approx. 3 VA (VAC) 1.5 W (VDC) Immunity to power micro cuts 10 ms Timing Control Specified time ranges (7) (IEC 1812-1) 0.5..10 s, 0.05..1 min, 0.5..10 min, 0.05.. 1h, 0.5..10 h, 0.05..1 day, 0.5..10 days Minimum control pulse duration (IEC 1812- 40 ms 1) 100 ms with load Recovery time (after by de-energisation) 120 ms (IEC 1812-1) Repeatability (IEC 1812-1) 0.5 % Setting Accuracy (IEC 1812-1) 10 % Temperature drift 0.05 % / C Voltage drift 0.2 % / V Relay output Contact arrangement 1 CO (SPDT) 2 CO (SPDT) 1 CO (SPDT) (ChangeOver -Single Pole Double (ChangeOver -Single (ChangeOver -Single Throw-) Pole Double Throw-) Pole Double Throw-) Maximum switching voltage 250 Va/ 10 A resistive / 125 Vc / 0.3 A resistive Switching current rate (resistive) NO / NC: NO / NC: NO / NC: 10 A 250 Va / 10 A 10 A 250 Va / 10 A 10 A 250 Va / 10 A 30 Vc 40 C 30 Vc 40 C 30 Vc 25 C NO / NC: NO / NC: NO / NC: 8 A 250 Va / 8 A 30 Vc 60 C 8 A 250 Va / 8 A 5 A 250 Va / 5 A 30 Vc 60 C 30 Vc 60 C Minimum switching contact 10 mA / 5 Vc Maximum switching power (resistive) 2500 VA / 300 W 5 Electrical life 10 cycles min at 250 Va/ 10 A resistive(NO only) Maximum rate (at max switching power) 360 cycles /hour 6 Mechanical life 10 x 10 cycles Rated impulse voltage 4 kV (1.2/50 s) Dielectric strength between coil / contacts 2.5 kV / 1 min / 1 mA / 50 Hz (IEC 60664-1) Dielectric strength between open contacts 1 kV /1 min / 1 mA / 50 Hz Insulation Rated Insulation voltage (IEC 60664-1) 250 V Insulation coordination (IEC 60664-1) Overvoltage category III pollution degree 2 up to 2 000 m above sea level Rated impulse voltage (IEC 60664-1) 4 kV (1.2/50s) Clearance / Creepage distances (IEC 3 mm / 3.2 mm 60664-1) Dielectric strength (EN-61812-1) 2.5 kV / 1 min / 1 mA / 50 Hz Insulation Resistance (NFC 93 050) > 500 MOhms / 250 Vc / 1 min General specifications Status indication (LED) Un: green LED blinks when count, flash when waiting Y1, continuous ON when supplied R: yellow LED blink when only R2 is ON (instantaneous), continuous ON when the 2 relays are ON. Casing 35 mm Mounting Mounting base-mounted on socket Housing material (UL94) Enclosure plastic type V0 Degree of protection (IEC 60529) IP40