11/2018 Plug-In Timer 11 pins Multifunction or monofunction Compact body for space saving Wide time range (from 0.5 seconds to 10 days delay) Universal power supply (12-240 Vz) 1 or 2 relay outputs (SPDT / Changeover) PU2R10MV1 PA2R10MV1 PC2R10MV1 PL2R10MV1 Protective cover Multifunctions U - Monofunction A, At Monofunction C Monofunction L, Li LED status indicator Monofunction Ad - Instantaneous 3-wire PNP sensor compatible 11-pins connections Product selection Function Output Supply Voltage Part Number Multifunction U: (A, At, B, C, H, 2 relays 12 to 240 Vz PU2R10MV1 Ht, D, Di, Ac, Bw) Ad - Instantaneous A, At 2 relays 12 to 240 Vz PA2R10MV1 C 2 relays 12 to 240 Vz PC2R10MV1 L, Li 2 relays 12 to 240 Vz PL2R10MV1 PART NUMBERING SYSTEM Type Output Quantity Output Power O: Plug-in 8-Pins 1: 1 Output 10: 10 A P: Plug-in 11-Pins 2: 2 Outputs P2U R 10 MV1 Function Output Type Power Supply A: ON-Delay R: Relay MV1: 12-240V AC/DC C: OFF-Delay L: Repeat Cycle U: Multifuction U You have a project Contact us on www.crouzet.com Description: Syr-line, the new specialized range at Crouzet, aimed to satisfy the most unique requirements of your applications by innovating in design, engineering and development. The Plug in Analog Timers, a new family of 11 timers with multifuction or monofunction, universal power supply, wide time range, with all the classic functions. For more information about Crouzets Syr-line range, please visit www.crouzet.com. CONTROL.CROUZET.COM 2 Plug-In Timer 11/2018 PU2R10MV1 PA2R10MV1 PC2R10MV1 PL2R10MV1 Power Supply Rated supply voltage Un 12 to 240 Vz Voltage supply tolerance -15 %, +10 % AC supply voltage frequency 50 / 60 Hz 5% Galvanic isolation of supply / inputs No Power consumption Un Approx. 3 VA (Va) 1.5 W (Vc) Immunity to power micro cuts 10 ms Timing Control Specified time ranges (7) (IEC 1812-1) 0.5..10 s, 0.05..1 min, 0.5..10 min, 0.05..1 h, 0.5..10 h, 0.05..1 day, 0.5..10 days Minimum control pulse duration 40 ms (IEC 1812-1) 100 ms with load Recovery time (after by de-energisation) 120 ms (IEC 1812-1) Repeatability (IEC 1812-1) 0.5 % Setting Accuracy (IEC 1812-1) 10 % Temperature drift 0.05 % / C Voltage drift 0.2 % / V Relay output Contact arrangement 2 CO (SPDT) 2 CO (SPDT) (ChangeOver -Single Pole Double Throw-) (ChangeOver -Single Pole Double Throw-) R1: Follow timing function R2: Follow timing function / Instantenous Maximum switching voltage 250 Va / 10 A resistive / 125 Vc / 0.3 A resistive Switching current rate (resistive) NO / NC: 10 A 250 Va / 10 A 30 Vc 25 C NO / NC: 5 A 250 Va / 5 A 30 Vc 60 C Minimum switching contact 10 mA / 5 Vc Maximum switching power (resistive) 2500 VA / 300 W 5 Electrical life 10 cycles min at 250 Va/ 10 A resistive (NO only) Maximum rate (at max switching power) 360 cycles /hour 6 Mechanical life 10 x 10 cycles Rated impulse voltage 4 kV (1.2/50 s) Dielectric strength between coil / contacts 2.5 kV / 1 min / 1 mA / 50 Hz (IEC 60664-1) Dielectric strength between open contacts 1 kV / 1 min / 1 mA / 50 Hz Insulation Rated Insulation voltage (IEC 60664-1) 250 V Insulation coordination (IEC 60664-1) Overvoltage category III pollution degree 2 up to 2000 m above sea level Rated impulse voltage (IEC 60664-1) 4 kV (1.2/50 s) Clearance / Creepage distances 3 mm / 3.2 mm (IEC 60664-1) Dielectric strength (EN-61812-1) 2.5 kV / 1 min / 1 mA / 50 Hz Insulation Resistance (NFC 93 050) > 500 MOhms / 250 Vc / 1 min General specifications Status indication (LED) Un: green LED blinks when count, flash when waiting Y1, continuous ON when supplied R: yellow LED blink when only R2 is ON (instantaneous), continuous ON when the 2 relays are ON. Casing 35 mm Mounting Mounting base-mounted on socket Housing material (UL94) Enclosure plastic type V0 Degree of protection (IEC 60529) IP40 Operating temperature (IEC 60068-2) -20 C to +60 C