Additional Resources: Product Page 3D Model date 02/10/2020 page 1 of 16 SERIES: CFM-80V DESCRIPTION: DC AXIAL FAN FEATURES TM omniCOOL bearing system 80 x 80 mm frame multiple speed options for different cooling needs tachometer signal and rotation detect options available auto restart protection standard on all models 4 input input input rated air static noise MODEL 1 1 1 2 3 voltage current power speed flow pressure rated range max max typ max (Vdc) (Vdc) (mA) (W) (RPM10%) (CFM) (inch H O) (dBA) 2 CFM-8015V-124-308 12 4.5~13.8 104 1.25 2400 30.0 0.09 30.8 CFM-8015V-127-320 12 4.5~13.8 149 1.79 2700 33.6 0.11 32.0 CFM-8015V-130-347 12 4.5~13.8 188 2.26 3000 37.0 0.14 34.7 CFM-8015V-224-308 24 8~27.6 65 1.56 2400 30.0 0.09 30.8 CFM-8015V-227-320 24 8~27.6 75 1.80 2700 33.6 0.11 32.0 CFM-8015V-230-347 24 8~27.6 106 2.55 3000 37.0 0.14 34.7 CFM-8020V-126-300 12 6~13.8 86 1.04 2600 29.0 0.12 30.0 CFM-8020V-130-350 12 6~13.8 110 1.32 3000 33.0 0.16 35.0 CFM-8020V-133-380 12 6~13.8 150 1.80 3300 36.0 0.18 38.0 CFM-8020V-139-430* 12 6~13.8 225 2.70 3900 45.0 0.26 43.0 CFM-8020V-142-450* 12 6~13.8 265 3.18 4200 49.0 0.31 45.0 CFM-8020V-146-480* 12 6~12.6 328 3.94 4600 53.0 0.36 48.0 CFM-8020V-226-300 24 8~27.6 49 1.18 2600 29.0 0.12 30.0 CFM-8020V-230-350 24 8~27.6 59 1.42 3000 33.0 0.16 35.0 CFM-8020V-233-380 24 8~27.6 74 1.78 3300 36.0 0.18 38.0 CFM-8025V-120-204 12 4.5~13.8 48 0.58 2000 23.9 0.07 20.4 CFM-8025V-126-280 12 4.5~13.8 75 0.90 2600 33.0 0.11 28.0 CFM-8025V-129-300 12 4.5~13.8 106 1.28 2900 37.0 0.15 30.0 CFM-8025V-132-330 12 4.5~13.8 138 1.66 3200 41.0 0.18 33.0 CFM-8025V-142-415 12 6~13.8 230 2.76 4200 53.0 0.30 41.5 CFM-8025V-145-431 12 6~13.8 276 3.32 4500 57.0 0.35 43.1 CFM-8025V-148-447 12 6~13.8 357 4.29 4800 60.0 0.41 44.7 CFM-8025V-226-280 24 8~27.6 48 1.16 2600 33.0 0.11 28.0 CFM-8025V-229-300 24 8~27.6 58 1.40 2900 37.0 0.15 30.0 Notes: 1. At rated voltage, 25C, 0 inch H 0 static pressure, after 10 minutes 2 2. As per AMCA 210 or DIN 24163, at rated voltage, stabilized RPM, 0 inch H 0 static pressure 2 3. As per AMCA 210 or DIN 24163, at rated voltage, stabilized RPM, 0 CFM airflow. 4. Measured in a semi-anechoic chamber with background noise < 15 dBA at 1 m from the fan intake. 5. All specifications are measured at 25C, 65% relativ e humidity unless otherwise specified. *. Discontinued models cuidevices.comAdditional Resources: Product Page 3D Model CUI Devices SERIES: CFM-80V DESCRIPTION: DC AXIAL FAN date 02/10/2020 page 2 of 16 4 input input input rated air static noise MODEL 1 1 1 2 3 voltage current power speed flow pressure rated range max max typ max (Vdc) (Vdc) (mA) (W) (RPM10%) (CFM) (inch H O) (dBA) 2 CFM-8025V-232-330 24 8~27.6 75 1.80 3200 41.0 0.18 33.0 CFM-8025V-242-435* 24 10~27.6 158 3.80 4200 53.0 0.30 43.5 CFM-8025V-245-450* 24 10~27.6 191 4.59 4500 57.0 0.35 45.0 CFM-8025V-442-435* 48 24~56.0 106 5.09 4200 53.0 0.30 43.5 CFM-8025V-445-450* 48 24~56.0 115 5.52 4500 57.0 0.35 45.0 Notes: 1. At rated voltage, 25C, 0 inch H 0 static pressure, after 10 minutes 2 2. As per AMCA 210 or DIN 24163, at rated voltage, stabilized RPM, 0 inch H 0 static pressure 2 3. As per AMCA 210 or DIN 24163, at rated voltage, stabilized RPM, 0 CFM airflow. 4. Measured in a semi-anechoic chamber with background noise < 15 dBA at 1 m from the fan intake. 5. All specifications are measured at 25C, 65% relativ e humidity unless otherwise specified. *. Discontinued models PART NUMBER KEY CFM-8015V-124-308 - XX - CXX Fan Signals Base Number Reserved for Custom blank = no signals Configurations 11 = rotation detector signal 20 = tachometer signal cuidevices.com