Additional Resources: Product Page date 07/28/2021 page 1 of 7 SERIES: AE10-EW-DIN DESCRIPTION: DC-DC CONVERTER FEATURES 10 watts high operating temp -40 to +70C 4,000 Vac isolation extra wide input voltage 10:1 input voltage up to 1 kVdc OVP protection output short circuit protection DIN-rail mounted EN 62109 approved 2 input output output output ripple efficiency MODEL 1 voltage voltage current power & noise range min max max max typ (Vdc) (Vdc) (A) (A) (W) (mVp-p) (%) AE10-EW-S5-DIN 100~1000 5 0 2.00 10 200 72 AE10-EW-S9-DIN 100~1000 9 0 1.11 10 200 76 AE10-EW-S24-DIN 100~1000 24 0 0.42 10 200 80 Notes: 1. Measured at nominal input, 20 MHz bandwidth oscilloscope, with 10 F electrolytic and 1 F ceramic capacitors on the output. 2. Measured at 200 Vdc input voltage, full load. 3. All specifications are measured at Ta=25C, humidity < 75%, nominal input voltage, and rated output load unless otherwise specified. PART NUMBER KEY AE10-EW - SXX - DIN Mounting Style: Base Number Output Voltage DIN = DIN-rail mount cui.comAdditional Resources: Product Page CUI Inc SERIES: AE10-EW-DIN DESCRIPTION: DC-DC CONVERTER date 07/28/2021 page 2 of 7 INPUT parameter conditions/description min typ max units operating input voltage 100 1000 Vdc at 200 Vdc 75 mA current at 600 Vdc 25 mA at 1000 Vdc 16 mA at 200 Vdc 7 A inrush current at 600 Vdc 20 A at 1000 Vdc 30 A input fuse 1 A / 1000 Vdc (external) OUTPUT parameter conditions/description min typ max units 5 Vdc output model 6,000 F maximum capacitive load 9 Vdc output model 4,000 F 24 Vdc output model 470 F voltage accuracy 1 2 % line regulation from low line to high line, full load 0.5 1 % load regulation from 0% to full load 0.5 1 % delay time from Vin = 0 V to 90% of rated ouptut voltage 1 s switching frequency 75 kHz temperature coefficient at full load 0.02 %/C PROTECTIONS parameter conditions/description min typ max units 5 Vdc output model 7.5 Vdc over voltage protection 9 Vdc output model 12 Vdc 24 Vdc output model 28 Vdc over current protection automatic recovery 110 % short circuit protection continuous, automatic recovery SAFETY AND COMPLIANCE parameter conditions/description min typ max units isolation voltage input to output for 1 minute 4,000 Vac safety approvals EN 62109 conducted emissions CISPR22/EN55022, class A (external circuit required, see Figure 2) radiated emissions CISPR22/EN55022, class A (external circuit required, see Figure 2) ESD IEC/EN61000-4-2, contact 6kV/air 8kV, class B radiated immunity IEC/EN61000-4-3, 10V/m, class A EFT/burst IEC/EN61000-4-4, 4kV, class B (external circuit required, see Figure 2) surge IEC/EN61000-4-5, 2kV, class B (external circuit required, see Figure 2) conducted immunity IEC/EN61000-4-6, 10 Vr.m.s, class A MTBF as per MIL-HDBK-217F, 25C 300,000 hours RoHS 2011/65/EU cui.com