Additional Resources: Product Page PCB Footprint date 07/29/2021 page 1 of 7 SERIES: AE15-EW DESCRIPTION: DC-DC CONVERTER FEATURES 15 watts high operating temp -40 to +70C 4,000 Vac isolation extra wide input voltage 10:1 input voltage up to 1 kVdc OVP protection output short circuit protection board mounted EN 62109 approved 2 input output output output ripple efficiency MODEL 1 voltage voltage current power & noise range min max max max typ (Vdc) (Vdc) (A) (A) (W) (mVp-p) (%) AE15-EW-S12 100~1000 12 0 1.25 15 200 77 AE15-EW-S15 100~1000 15 0 1.00 15 200 78 AE15-EW-S24 100~1000 24 0 0.625 15 200 80 Notes: 1. Measured at nominal input, 20 MHz bandwidth oscilloscope, with 10 F electrolytic and 1 F ceramic capacitors on the output. 2. Measured at 200 Vdc input voltage, full load. 3. All specifications are measured at Ta=25C, humidity < 75%, nominal input voltage, and rated output load unless otherwise specified. PART NUMBER KEY AE15-EW - SXX Base Number Output Voltage cui.comAdditional Resources: Product Page PCB Footprint CUI Inc SERIES: AE15-EW DESCRIPTION: DC-DC CONVERTER date 07/29/2021 page 2 of 7 INPUT parameter conditions/description min typ max units operating input voltage 100 1000 Vdc at 200 Vdc 120 mA current at 600 Vdc 40 mA at 1000 Vdc 22 mA at 200 Vdc 7 A inrush current at 600 Vdc 20 A at 1000 Vdc 30 A input fuse 2 A / 1000 Vdc (external) OUTPUT parameter conditions/description min typ max units 12 Vdc output model 2,000 F maximum capacitive load 15 Vdc output model 1,200 F 24 Vdc output model 470 F voltage accuracy 1 2 % line regulation from low line to high line, full load 0.5 1 % load regulation from 0% to full load 0.5 1 % delay time from Vin = 0 V to 90% of rated ouptut voltage 1 s switching frequency 75 kHz temperature coefficient at full load 0.02 %/C PROTECTIONS parameter conditions/description min typ max units 12 Vdc output model 15 Vdc over voltage protection 15 Vdc output model 19 Vdc 24 Vdc output model 28 Vdc over current protection automatic recovery 110 % short circuit protection continuous, automatic recovery SAFETY AND COMPLIANCE parameter conditions/description min typ max units isolation voltage input to output for 1 minute 4,000 Vac safety approvals EN 62109 conducted emissions CISPR22/EN55022, class A (external circuit required, see Figure 2) radiated emissions CISPR22/EN55022, class A (external circuit required, see Figure 2) ESD IEC/EN61000-4-2, contact 6kV/air 8kV, class B radiated immunity IEC/EN61000-4-3, 10V/m, class A EFT/burst IEC/EN61000-4-4, 4kV, class B (external circuit required, see Figure 2) surge IEC/EN61000-4-5, 2kV, class B (external circuit required, see Figure 2) conducted immunity IEC/EN61000-4-6, 10 Vr.m.s, class A MTBF as per MIL-HDBK-217F, 25C 300,000 hours RoHS 2011/65/EU cui.com