Additional Resources: Product Page 3D Model date 11/11/2019 page 1 of 4 SERIES: EMC-03 DESCRIPTION: AC POWER LINE FILTER FEATURES reduces emissions to help comply with CISPR22 / EN 55022 Class B protects against surge events and Electrical Fast Transients wide input voltage range (85 ~ 305 Vac) 0.3 A rated current -40 to +85C temperature range SPECIFICATIONS parameter conditions/description min typ max units input voltage 85 305 Vac input current 0.3 A RoHS yes operating temperature -40 85 C storage temperature -40 105 C case temperature rise at 220 Vac, 0.3 A 30 C leakage current (line to ground) 2000 Vac, tested for 1 minute 2 mA EFT IEC/EN61000-4-4, +/-4 kV surge IEC/EN61000-4-5, +/-1 kV (2 ohms) / +/-2 kV (12 ohms) PART NUMBER KEY EMC-03 Base Number cui.comAdditional Resources: Product Page 3D Model CUI Inc SERIES: EMC-03 DESCRIPTION: AC POWER LINE FILTER date 11/11/2019 page 2 of 4 MECHANICAL parameter conditions/description min typ max units dimensions 33.70 x 22.20 x 18.00 1.327 x 0.874 x 0.709 inch mm case material black flame-retardant heat-proof epoxy resin (UL94V-0) weight 20 g MECHANICAL DRAWING units: mm inch tolerance: 0.50 0.020 pin diameter tolerance: 0.10 0.004 PIN CONNECTIONS PIN Function 1 GND 2 IN(N) 3 IN(L) 4 OUT(L) Recommended PCB Layout 5 OUT(N) Top View Supporting Product Table Model EMI Surge EFT PBO-1 CISPR22/EN55022 CLASS B IEC/EN61000-4-5 1KV/2KV, perf. Criteria B IEC/EN61000-4-4 4KV, perf. Criteria B PBO-3 CISPR22/EN55022 CLASS B IEC/EN61000-4-5 1KV/2KV, perf. Criteria B IEC/EN61000-4-4 4KV, perf. Criteria B PBO-5 CISPR22/EN55022 CLASS B IEC/EN61000-4-5 1KV/2KV, perf. Criteria B IEC/EN61000-4-4 4KV, perf. Criteria B cui.com