Additional Resources: Product Page date 06/07/2016 page 1 of 7 SERIES: PBK-5 DESCRIPTION: AC-DC POWER SUPPLY FEATURES up to 5 W continuous output ultr a compact SIP package universal input voltage: (85~264 Vac / 100~400 Vdc) single regulated outputs from 3.3~24 Vdc 3,000 Vac isolation over current, short circuit, and over voltage protections UL 60950-1 safety approval efficiency up to 75% output output output ripple efficiency MODEL 1 voltage current power and noise max max max typ (Vdc) (A) (W) (mVp-p) (%) PBK-5-3 3.3 1 3.3 150 65 PBK-5-5 5 1 5 120 70 PBK-5-9 9 0.56 5 120 72 PBK-5-12 12 0.42 5 120 74 PBK-5-15 15 0.34 5 120 75 PBK-5-24 24 0.21 5 150 75 Note: 1. Measured at 20 MHz bandwidth, see Test Configuration section. PART NUMBER KEY PBK-5- XX - X Base Number Output Voltage Orientation blank = vertical B = right-angle cui.com DISCONTINUEDAdditional Resources: Product Page CUI Inc SERIES: PBK-5 DESCRIPTION: AC-DC POWER SUPPLY date 06/07/2016 page 2 of 7 INPUT parameter conditions/description min typ max units 85 264 Vac voltage 100 400 Vdc frequency 47 440 Hz at 115 Vac 200 mA current at 230 Vac 100 mA at 115 Vac 20 A inrush current at 230 Vac 30 A leakage current CY0 is 1nF/400Vac 0.25 mA no load power consumption 0.5 W input fuse 1 A/250 V, slow-blow type (external, recommended) OUTPUT parameter conditions/description min typ max units output current 10 % 3.3 Vdc output models 2200 F 5 Vdc output models 1500 F 9 Vdc output models 680 F capacitive load 12 Vdc output models 470 F 15 Vdc output models 330 F 24 Vdc output models 100 F line regulation at full load 0.1 0.5 % load regulation at 10%~100% load 1.0 1.5 % PBK-5-3 2 3 % voltage set accuracy all other models 1 2 % at 115 Vac 20 ms hold-up time at 230 Vac 80 ms switching frequency 100 kHz temperature coefficient 0.02 %/C PROTECTIONS parameter conditions/description min typ max units short circuit protection continuous, auto restart over current protection auto restart 110 % over voltage protection zener diode clamp SAFETY & COMPLIANCE parameter conditions/description min typ max units isolation voltage input to output for 1 minute at 5mA 3,000 Vac isolation resistance 100 M safety approvals UL 60950-1 safety standards UL 60950-1 safety class class II conducted emissions CISPR22/EN55022 external circuit required, Class A (see figure 2) Class B (see figure 3) radiated emissions CISPR22/EN55022 external circuit required, Class B (see figures 2 or 3) ESD IEC/EN61000-4-2 Class B, contact 4 kV radiated immunity IEC/EN61000-4-3 Class A, 10V/m IEC/EN61000-4-4 Class B, 2 kV (external circuit required, see figure 2) EFT/burst IEC/EN61000-4-4 Class B, 4 kV (external circuit required, see figure 3) cui.com DISCONTINUED