Additional Resources: Product Page 3D Model PCB Footprint date 11/12/2020 page 1 of 8 SERIES: PBO-10C DESCRIPTION: INTERNAL AC-DC POWER SUPPLY FEATURES wide input range (85 ~ 305 Vac) wide operating temperature range (-40 to +85 C) IEC/EN/UL 62368 certified designed to meet 61558 & 60335 safety standards 1,000,000 hour MTBF flexible implementations to power a wide array of applications output output output ripple efficiency MODEL voltage current power and noise max max typ typ (Vdc) (A) (W) (mVp-p) (%) PBO-10C-3 3.3 2.0 6.6 150 73.0 PBO-10C-5 5.0 2.0 10.0 150 77.0 PBO-10C-9 9.0 1.1 10.0 150 80.0 PBO-10C-12 12.0 0.83 10.0 150 82.0 PBO-10C-15 15.0 0.67 10.0 150 82.0 PBO-10C-24 24.0 0.42 10.0 150 83.0 Note: 1. At full load, nominal input, 20 MHz bandwidth oscilloscope, see Application Circuit. 2. At 230 Vac input. PART NUMBER KEY PBO-10C - XX Base Number Output Voltage cui.comAdditional Resources: Product Page 3D Model PCB Footprint CUI Inc SERIES: PBO-10C DESCRIPTION: AC-DC POWER SUPPLY date 11/12/2020 page 2 of 8 INPUT parameter conditions/description min typ max units ac input 85 305 Vac voltage dc input 100 430 Vdc frequency 47 63 Hz at 115 Vac 0.30 A current at 230 Vac 0.18 A at 115 Vac 15 A inrush current at 277 Vac 30 A at 230 Vac 3.3 & 5 Vdc output models 0.10 W no load power consumption 9, 12 & 15 Vdc output models 0.12 W 24 Vdc output models 0.15 W OUTPUT parameter conditions/description min typ max units 3.3 Vdc output models 1,500 F 5 Vdc output models 1,500 F 9 Vdc output models 1,000 F capacitive load 12 Vdc output models 680 F 15 Vdc output models 470 F 24 Vdc output models 330 F 3.3 Vdc output 3 % initial set point accuracy other outputs 2 % line regulation at rated load 1 % load regulation 0% ~ 100% load 1.5 % temperature coefficient 0.02 %/C PROTECTIONS parameter conditions/description min typ max units output voltage clamp & hiccup 3.3 & 5 Vdc output models 9.0 Vdc 9 Vdc output models 15.0 Vdc over voltage protection 12 Vdc output models 16.0 Vdc 15 Vdc output models 21.0 Vdc 24 Vdc output models 32.0 Vdc over current protection auto recovery 110 % short circuit protection continuous, auto recovery, hiccup SAFETY & COMPLIANCE parameter conditions/description min typ max units isolation voltage input to output for 1 minute, leakage current <5mA 3,000 Vac certified to 62368: IEC/EN/UL safety approvals designed to meet 61558: IEC, EN designed to meet 60335: IEC, EN safety class class II CISPR32/EN55032 CLASS A (Recommended circuit 1, 4) EMI/EMC CISPR32/EN55032 CLASS B (Recommended circuit 2, 3) ESD IEC/EN 61000-4-2 Contact 6KV perf. Criteria B radiated immunity IEC/EN61000-4-3 10V/m perf. Criteria A IEC/EN61000-4-4 2KV (Recommended circuit 1, 2) perf. Criteria B EFT/burst IEC/EN61000-4-4 4KV (Recommended circuit 3, 4) perf. Criteria B IEC/EN61000-4-5 line to line 1KV (Recommended circuit 1, 2) perf. Criteria B surge IEC/EN61000-4-5 line to line2KV (Recommended circuit 3, 4) perf. Criteria B conducted immunity IEC/EN61000-4-6 10Vr.m.s perf. Criteria A cui.com