Additional Resources: Product Page 3D Model PCB Footprint date 09/06/2021 page 1 of 10 SERIES: PRQ100W-D DESCRIPTION: DC-DC CONVERTER FEATURES 100W isolated output -Brick package with industry standard pin-out ultra-wide input voltage range single regulated output high efficiency up to 94% output short circuit, over current, over voltage, & over temperature protection 2250 Vdc isolation EN62368 approved available with heat sink or base plate CTRL pin 2 input output output output ripple efficiency MODEL 1 voltage voltage current power & noise Vo1/Vo2 max range max max max min/typ (Vdc) (Vdc) (Vdc) (A) (W) (mVp-p) (%) PRQ100W-Q24-S5 40 9~36 5 20 100 250 87/89 PRQ100W-Q24-S12 40 9~36 12 8.3 100 200 88/90 PRQ100W-Q24-S15 40 9~36 15 6.7 100 200 88/90 PRQ100W-Q24-S24 40 9~36 24 4.2 100 250 88/90 PRQ100W-Q24-S48 40 9~36 48 2.1 100 250 88/90 PRQ100W-Q48-S5 80 18~75 5 20 100 250 91/93 PRQ100W-Q48-S12 80 18~75 12 8.3 100 200 91/93 PRQ100W-Q48-S15 80 18~75 15 6.7 100 200 92/94 PRQ100W-Q48-S24 80 18~75 24 4.2 100 250 91/93 PRQ100W-Q48-S48 80 18~75 48 2.1 100 250 91/93 Notes: 1. 20MHz bandwidth, nominal input, full load 2. Efficiency is measured with 24 V input voltage and rated output load. PART NUMBER KEY PRQ100W - QXX - SXX - X - D Mounting Style: D = DIP Input Voltage Base Number blank = board mount, no heatsink Output voltage H = heat sink B = base plate cui.comAdditional Resources: Product Page 3D Model PCB Footprint CUI Inc SERIES: PRQ100W-D DESCRIPTION: DC-DC CONVERTER date 09/06/2021 page 2 of 10 INPUT parameter conditions/description min typ max units operating input voltage 9 24 40 Vdc start-up voltage 9 Vdc surge voltage for maximum of 1 second -0.7 50 Vdc current full load / no load 4.68/0.12 4.79/0.16 A filter Pi filter module on: CTRL open or pulled high (3.5~12 V) CTRL module off: CTRL pulled low to GND (0~1.2 V) OUTPUT parameter conditions/description min typ max units output voltage 5 Vdc 6,000 F maximum capacitive load 12 Vdc & 15 Vdc 2,000 F 24 Vdc 1,000 F 48 Vdc 470 F voltage accuracy 0% to full load 3 % line regulation from low line to high line, full load 0.5 % load regulation 5% to full load 0.75 % switching frequency PWM mode 250 kHz transient recovery time 25% load step change, nominal input voltage 200 500 s transient response deviation 25% load step change, nominal input voltage 3 5 % temperature coefficient at full load 0.03 %/C adjustability see trim resistor connection 10 % remote sense see remote sense application circuit 110 %Vo cui.com