Additional Resources: Product Page 3D Model PCB Footprint datdatee 08/18/2021 pagepage 1 of 71 of 7 SERIES: PYB15 DESCRIPTION: DC-DC CONVERTER FEATURES up to 15 W isolated output industry standard pinout 4:1 input range (9~36 Vdc, 18~75 Vdc) smaller package single/dual regulated outputs 1,500 Vdc isolation continuous short circuit, over current protection, over voltage protection temperature range (-40~85C) six-sided metal shielding efficiency up to 90% EN 62368-1 input output output output ripple efficiency MODEL 2 voltage voltage current power and noise typ range min max max max typ (Vdc) (Vdc) (Vdc) (mA) (mA) (W) (mVp-p) (%) PYB15-Q24-S3 24 9~36 3.3 200 4000 13.2 100 87 PYB15-Q24-S5 24 9~36 5 150 3000 15 100 90 PYB15-Q24-S12 24 9~36 12 63 1250 15 100 89 PYB15-Q24-S15 24 9~36 15 50 1000 15 100 89 PYB15-Q24-S24 24 9~36 24 31 625 15 100 90 PYB15-Q24-D5 24 9~36 5 75 1500 15 100 86 PYB15-Q24-D12 24 9~36 12 32 625 15 100 88 PYB15-Q24-D15 24 9~36 15 25 500 15 100 88 1 PYB15-Q48-S3 48 18~75 3.3 200 4000 13.2 100 87 1* PYB15-Q48-S5 48 18~75 5 150 3000 15 100 89 1 PYB15-Q48-S12 48 18~75 12 63 1250 15 100 88 1 PYB15-Q48-S15 48 18~75 15 50 1000 15 100 90 PYB15-Q48-D5 48 18~75 5 75 1500 15 100 86 PYB15-Q48-D12 48 18~75 12 32 625 15 100 88 PYB15-Q48-D15 48 18~75 15 25 500 15 100 89 Notes: 1. UL approved 2. Ripple and noise are measured at 20 MHz BW by parallel cable method with 1 F ceramic and 10 F electrolytic capacitors on the output. 3. * Discontinued model. PART NUMBER KEY PYB15 - QXX - XXX - X Heatsink* Base Numberblan = no heatsink Output Voltage Input Voltage H = with heatsink Output S = single D = dual Notes: *Discontinued heatsink versions. cui.comAdditional Resources: Product Page 3D Model PCB Footprint CUI Inc SERIES: PYB15 DESCRIPTION: DC-DC CONVERTER date 08/18/2021 page 2 of 7 INPUT parameter conditions/description min typ max units 24 Vdc input models 9 24 36 Vdc operating input voltage 48 Vdc input models 18 48 75 Vdc 24 Vdc input models 9 Vdc start-up voltage 48 Vdc input models 17.8 Vdc 24 Vdc input models 7.5 Vdc 1 under voltage shutdown 48 Vdc input models 16 Vdc for maximum of 1 second surge voltage 24 Vdc input models -0.7 50 Vdc 48 Vdc input models -0.7 100 Vdc start-up time nominal input, constant load 10 ms filter pi filter models ON (CTRL open or connect TTL high level, 2.5~12 Vdc) 2 CTRL models OFF (CTRL connect GND or low level, 0~1.2 Vdc) input current (models OFF) 1 mA Notes: 1. Contact CUI if you are planning to use this feature in your application. 2. CTRL pin voltage is referenced to GND. OUTPUT parameter conditions/description min typ max units line regulation full load, input voltage from low to high 0.2 0.5 % load regulation 5% to 100% load 0.5 1 % dual output models: cross regulation main output 50% load, secondary output from 5 % 10% to 100% load voltage accuracy 1 3 % 3 voltage balance dual output, balanced loads 0.5 1 % 4 adjustability 10 % switching frequency PWM mode 300 kHz transient recovery time 25% load step change 300 500 s transient response deviation 25% load step change 3 5 % temperature coefficient 100% load 0.02 %/C Note: 3. For dual output models, unbalanced loads should not exceed 5%. If 5% is exceeded, it may not meet all specifications. 4. Output trimming available on single output models only. PROTECTIONS parameter conditions/description min typ max units short circuit protection hiccup, continuous, automatic recovery over current protection 160 % 3.3 Vdc output models 3.9 Vdc 5 Vdc output models 6.2 Vdc over voltage protection 12 Vdc output models 15 Vdc 15 Vdc output models 18 Vdc 24 Vdc output models 30 Vdc SAFETY AND COMPLIANCE parameter conditions/description min typ max units isolation voltage input to output for 1 minute at 1 mA max. 1,500 Vdc isolation resistance input to output at 500 Vdc 1,000 M 5 safety approvals certified to 62368-1: EN certified to 60950-1: UL Note: 5. See specific models noted on page 1, excludes heat sink versions. cui.com