Additional Resources: Product Page 3D Model datdatee 02/15/2021 pagepage 1 of 81 of 8 SERIES: PYB20-T & PYB20-U DESCRIPTION: DC-DC CONVERTER FEATURES up to 20 W isolated output industry standard pinout 4:1 input range (9~36 Vdc, 18~75 Vdc) smaller package single/dual regulated outputs 1,500 Vdc isolation continuous short circuit, over current protection, over voltage protection reverse polarity protection on chassis mount (-T) models temperature range (-40~85C) six-sided metal shielding efficiency up to 90% EN 62368-1 2 input output output output ripple efficiency MODEL 1 voltage voltage current power and noise typ range min max max max typ (Vdc) (Vdc) (Vdc) (mA) (mA) (W) (mVp-p) (%) PYB20-Q24-S3 24 9~36 3.3 250 5000 16.5 100 86 PYB20-Q24-S5 24 9~36 5 200 4000 20 100 90 PYB20-Q24-S12 24 9~36 12 84 1667 20 100 89 PYB20-Q24-S15 24 9~36 15 67 1333 20 100 90 PYB20-Q24-S24 24 9~36 24 42 834 20 100 90 PYB20-Q24-D5 24 9~36 5 100 2000 20 100 86 PYB20-Q24-D12 24 9~36 12 42 834 20 100 88 PYB20-Q24-D15 24 9~36 15 33 667 20 100 88 PYB20-Q48-S3 48 18~75 3.3 250 5000 16.5 100 86 PYB20-Q48-S5 48 18~75 5 200 4000 20 100 90 PYB20-Q48-S12 48 18~75 12 84 1667 20 100 89 PYB20-Q48-S15 48 18~75 15 67 1333 20 100 90 PYB20-Q48-S24 48 18~75 24 42 834 20 100 90 PYB20-Q48-D5 48 18~75 5 100 2000 20 100 86 PYB20-Q48-D12 48 18~75 12 42 834 20 100 88 PYB20-Q48-D15 48 18~75 15 33 667 20 100 89 Notes: 1. Ripple and noise are measured at 20 MHz BW by parallel cable method with 1 F ceramic and 10 F electrolytic capacitors on the output. 2. Efficiency is approximately 2% lower for chassis mount (-T) models. 3. EN 62398-1 certification does not apply to U-fr ame models. PART NUMBER KEY PYB20 - QXX - XXX - X - X Mounting Type Base Number T = Chassis mount U = U-frame3 Input Voltage * Heatsink Outputblan = no heatsink S = single Output Voltage H = with heatsink Notes: *Discontinued heatsink versions. D = dual cui.comAdditional Resources: Product Page 3D Model CUI Inc SERIES: PYB20-T & PYB20-U DESCRIPTION: DC-DC CONVERTER date 02/15/2021 page 2 of 8 INPUT parameter conditions/description min typ max units 24 Vdc input models 9 24 36 Vdc operating input voltage 48 Vdc input models 18 48 75 Vdc 24 Vdc input models 9 Vdc start-up voltage 48 Vdc input models 17.8 Vdc 24 Vdc input models 7.5 Vdc 1 under voltage shutdown 48 Vdc input models 16 Vdc for maximum of 1 second surge voltage 24 Vdc input models -0.7 50 Vdc 48 Vdc input models -0.7 100 Vdc start-up time nominal input, constant load 10 ms filter pi filter models ON (CTRL open or connect TTL high level, 2.5~12 Vdc) 2 CTRL models OFF (CTRL connect GND or low level, 0~1.2 Vdc) input current (models OFF) 1 mA Notes: 1. Contact CUI if you are planning to use this feature in your application. 2. CTRL pin voltage is referenced to GND. OUTPUT parameter conditions/description min typ max units line regulation full load, input voltage from low to high 0.2 0.5 % load regulation 5% to 100% load 0.5 1 % dual output models: cross regulation main output 50% load, secondary output from 5 % 10% to 100% load voltage accuracy 1 3 % 3 voltage balance dual output, balanced loads 0.5 1 % 4 adjustability 10 % switching frequency PWM mode 300 kHz transient recovery time 25% load step change 300 500 s transient response deviation 25% load step change 3 5 % temperature coefficient 100% load 0.02 %/C Note: 3. For dual output models, unbalanced loads should not exceed 5%. If 5% is exceeded, it may not meet all specifications. 4. Output trimming available on single output models only. PROTECTIONS parameter conditions/description min typ max units short circuit protection hiccup, continuous, automatic recovery over current protection 160 % 3.3 Vdc output models 3.9 Vdc 5 Vdc output models 6.2 Vdc over voltage protection 12 Vdc output models 15 Vdc 15 Vdc output models 18 Vdc 24 Vdc output models 30 Vdc SAFETY AND COMPLIANCE parameter conditions/description min typ max units isolation voltage for 1 minute at 1 mA max. 1,500 Vdc isolation resistance at 500 Vdc 1,000 M cui.com