Additional Resources: Product Page 3D Model date 09/13/2021 page 1 of 6 SERIES: SDI120G-U DESCRIPTION: AC-DC POWER SUPPLY FEATURES up to 120 W continuous power gallium nitride (GaN) technology universal input over voltage, over current and short cicuit protections IEC 62368-1 compliant compact design custom design available output output output ripple efficiency MODEL 1 voltage current power and noise level max max max (Vdc) (A) (W) (mVp-p) SDI120G-12-U 12 9.0 108.0 150 VI SDI120G-19-U 19 6.3 119.7 190 VI SDI120G-20-U 20 6.0 120.0 200 VI SDI120G-24-U 24 5.0 120.0 240 VI SDI120G-48-U 48 2.5 120.0 480 VI SDI120G-56-U 56 2.14 119.8 560 VI Notes: 1. At full load, nominal input, 20 MHz bandwidth oscilloscope, each output terminated with 0.1 F multilayer ceramic and 10 F low ESR electrolytic capacitors. PART NUMBER KEY SDI120 - XX - UX - P51 - CXX AC Inlet Type: Base Number Reserved for Custom IEC320/C14 Configurations Output Voltage Input Cable: DC Plug Blank = No Cable C = North America input cable 2 = Europe input cable 3 = United Kingdom input cable 4 = Australia input cable 5 = China input cable 6 = South Korea input cable 7 = Brazil input cable 8 = South Africa input cable 9 = Japan input cable cui.comAdditional Resources: Product Page 3D Model CUI Inc SERIES: SDI120G-U DESCRIPTION: AC-DC POWER SUPPLY date 09/13/2021 page 2 of 6 INPUT parameter conditions/description min typ max units voltage 100 240 Vac frequency 50 60 Hz current 1.6 A inrush current at 230 Vac, full load, 25C, cold start 80 A leakage current 3.5 mA power factor correction at 115 & 230 Vac, full load 0.9 no load power consumption at 115 & 230 Vac, no load 0.15 W OUTPUT parameter conditions/description min typ max units regulation 5 % PROTECTIONS parameter conditions/description min typ max units over voltage protection output shut down with latch 150 % over current protection output shut down, auto recovery 150 % short circuit protection output shut down, auto recovery over temperature protection latch SAFETY & COMPLIANCE parameter conditions/description min typ max units input to output at 10 mA for 1 minute 3,000 Vac isolation voltage input to frame ground at 10 mA for 1 minute 1,770 Vac input to output at 500 Vdc 10 M isolation resistance input to frame ground at 500 Vdc 10 M safety approvals 62368: UL/cUL, UKCA FCC Part 15 subpart B, class B ANSI C63.4-2014 ICES-003 issue 6 EMI/EMC EN55032: 2015 EN 55035: 2017 EN 61000-3-2 AS/NZS CISPR 32: 2015 MTBF as per Telcordia SR-332, 25C 300,000 hrs RoHS yes ENVIRONMENTAL parameter conditions/description min typ max units operating temperature see derating curve -20 40 C storage temperature -20 80 C operating humidity non-condensing 20 80 % storage humidity non-condensing 10 90 % cui.com