Additional Resources: Product Page | 3D Model
date 08/28/2018
page 1 of 5
SERIES: SDI200-U DESCRIPTION: AC-DC POWER SUPPLY
FEATURES
level VI efficiency
200 W power
universal input (90~264 Vac)
single regulated outputs
over voltage and short circuit protections
UL/cUL (60950-1 & 62368-1), PSE safety approvals
power factor correction
custom designs available
output output output ripple efficiency
MODEL
1
voltage current power and noise level
max max max
(Vdc) (A) (W) (mVp-p)
2
SDI200-12-U 12 16 192 150 VI
SDI200-13.5-U 13.5 14 189 200 VI
SDI200-19-U 19 10.5 200 190 VI
2
SDI200-24-U 24 8.3 200 240 VI
2
SDI200-48-U 48 4.17 200 480 VI
2
SDI200-56-U 56 3.58 200 560 VI
Notes: 1. At full load, nominal input, 20 MHz bandwidth oscilloscope, output terminated with 0.1 F multilayer ceramic and 10 F low ESR electrolytic capacitors.
2. CoC Tier 2 compliant.
PART NUMBER KEY
SDI200 - XX - UX - P51 - CXX
AC Inlet Type:
Base Number
Reserved for Custom
IEC320/C14
Configurations
Output Voltage
Input Cable:
DC Plug Type:
Blank = No Cable
4 Pin Power DIN
C = North America input cable
2 = Europe input cable
3 = United Kingdom input cable
4 = Australia input cable
5 = China input cable
6 = South Korea input cable
7 = Brazil input cable
8 = South Africa input cable
9 = Japan input cable
cui.comAdditional Resources: Product Page | 3D Model
CUI Inc SERIES: SDI200-U DESCRIPTION: AC-DC POWER SUPPLY date 08/28/2018 page 2 of 5
INPUT
parameter conditions/description min typ max units
voltage 90 264 Vac
frequency 47 63 Hz
current 2.8 A
inrush current at 240 Vac, full load, 25C, cold start 100 A
leakage current 3.5 mA
power factor correction at 115/230 Vac, full load 0.9
12, 24, 48, 56 Vdc output models 0.15 W
no load power consumption
all other models 0.21 W
OUTPUT
parameter conditions/description min typ max units
regulation 5 %
PROTECTIONS
parameter conditions/description min typ max units
over voltage protection output latch 150 %
over current protection output shut down, auto recovery 150 %
short circuit protection output shut down
over temperature protection output latch
SAFETY & COMPLIANCE
parameter conditions/description min typ max units
input to output at 10 mA for 1 minute 3,000 Vac
isolation voltage
input to ground at 10 mA for 1 minute 1,500 Vac
input to output at 500 Vdc 10 M
isolation resistance
input to ground at 500 Vdc 10 M
safety approvals UL/cUL (60950-1, 62368-1), PSE
EMI/EMC FCC Part 15B Class B, CE
MTBF as per Telcordia SR-332, 25C 300,000 hours
RoHS yes
ENVIRONMENTAL
parameter conditions/description min typ max units
operating temperature 0 40 C
storage temperature -20 80 C
operating humidity non-condensing 20 80 %
storage humidity non-condensing 10 90 %
cui.com