Additional Resources: Product Page 3D Model date 09/28/2020 page 1 of 6 SERIES: VGS-100C DESCRIPTION: INTERNAL AC-DC POWER SUPPLY FEATURES universal input range (85 ~ 264 VAC) UL/EN/IEC 62368 certified designed to meet IEC/EN 61558, IEC/EN 60335, and GB4943 system requirements short-circuit, over-current, over-voltage protections CISPR/EN55032 Class B radiated/conducted emissions output adjustable via trimpot +/- 10% 2 output output output ripple efficiency MODEL 1 voltage current power and noise max max typ typ (Vdc) (A) (W) (mVp-p) (%) VGS-100C-5 5 18 90.0 100 86 VGS-100C-12 12 8.5 102.0 120 88 VGS-100C-15 15 7.0 105.0 120 88 VGS-100C-24 24 4.5 108.0 150 90 VGS-100C-36 36 2.8 100.8 200 90 VGS-100C-48 48 2.3 110.4 200 91 Notes: 1. Ripple & noise are measured at 20 MHz BW with 47 F aluminum electrolytic capacitor and 0.1 F ceramic capacitor on the output. 2. Measured at 230 Vac PART NUMBER KEY VGS-100C - XX - X A - with terminal cover Base Number Output Voltage B - with conformal coating cui.comAdditional Resources: Product Page 3D Model CUI Inc SERIES: VGS-100C DESCRIPTION: AC-DC POWER SUPPLY date 09/28/2020 page 2 of 6 INPUT parameter conditions/description min typ max units ac input 85 264 Vac voltage dc input 120 373 Vdc frequency 47 63 Hz at 115 Vac 3 A current at 230 Vac 1.5 A at 115 Vac, cold start 35 A inrush current at 230 Vac, cold start 65 A leakage current at 240 Vac 0.75 mA no load power consumption 5V, 12V, 15V, 24V at 230 Vac 0.3 W 36V, 48V at 230 Vac 0.5 W OUTPUT parameter conditions/description min typ max units 5 Vdc output 10,000 F 12 Vdc output 6,800 F 15 Vdc output 3,300 F capacitive load 24 Vdc output 2,200 F 36 Vdc output 1,000 F 48 Vdc output 470 F 5 Vdc output at full load 2 % initial set point accuracy other outputs at full load 1 % line regulation 0.5 % 5 Vdc output 0%~100% load 1 % load regulation other outputs 0%~100% load 0.5 % adjustability built in trim pot 10 % at 115 Vac 5 ms hold-up time at 230 Vac 45 ms switching frequency 65 kHz temperature coefficient 0.03 %/C PROTECTIONS parameter conditions/description min typ max units 5 Vdc output, output shut-down, auto-recovery 7.5 Vdc 12 Vdc output, output shut-down, auto-recovery 19.2 Vdc 15 Vdc output, output shut-down, auto-recovery 24.0 Vdc over voltage protection 24 Vdc output, output shut-down, auto-recovery 38.4 Vdc 36 Vdc output, output shut-down, auto-recovery 57.6 Vdc 48 Vdc output, output shut-down, auto-recovery 60.0 Vdc over current protection auto-recovery 110 160 % short circuit protection hiccup, continuous, auto-recovery SAFETY & COMPLIANCE parameter conditions/description min typ max units input to ground 2,000 Vac isolation voltage input to output 4,000 Vac output to ground 1,250 Vac certified to: 62368: IEC/EN/UL designed to meet: 60335: IEC/EN safety approvals designed to meet: 61558: IEC/EN designed to meet: 4943: GB safety class Class I EMI/EMC CISPR32/EN55032 Class B, IEC/EN61000-3-2 Class A ESD IEC/EN 61000-4-2 Contact 6KV /Air 8KV, perf. Criteria A cui.com