Additional Resources: Product Page 3D Model date 06/04/2021 page 1 of 5 SERIES: VGS-100W DESCRIPTION: INTERNAL AC-DC POWER SUPPLY FEATURES wide input range (85 ~ 305 VAC) available with conformal coating or terminal cover options UL/EN/IEC 62368 certified designed to meet IEC/EN 61558 and IEC/EN 60335 system requirements short-circuit, over-current, over-voltage protections CISPR/EN55032 Class B radiated/conducted emissions output output output ripple efficiency MODEL 1 voltage current power and noise max max typ typ (Vdc) (A) (W) (mVp-p) (%) VGS-100W-5 5 18.0 90 100 85.5 VGS-100W-12 12 8.5 102 120 87.0 VGS-100W-15 15 7.0 105 120 87.0 VGS-100W-24 24 4.5 108 150 89.5 VGS-100W-36 36 2.8 100 200 89.5 VGS-100W-48 48 2.3 110 200 90.5 Notes: 1. Ripple & noiswe are measured at 20 MHz BW with 47 F aluminum electrolytic capacitor and 0.1 F ceramic capacitor on the output. 2. Measured at 230 Vac. PART NUMBER KEY VGS-100W-XX-X Base Number Output Voltage A - with terminal cover B - with conformal coating cui.comAdditional Resources: Product Page 3D Model CUI Inc SERIES: VGS-100W DESCRIPTION: AC-DC POWER SUPPLY date 06/04/2021 page 2 of 5 INPUT parameter conditions/description min typ max units ac input 85 305 Vac voltage dc input 120 431 Vdc frequency 47 63 Hz at 115 Vac 3 A current at 230 Vac 1.5 A inrush current at 115 Vac, cold start 35 A at 230 Vac, cold start 65 A leakage current at 277 Vac 0.75 mA no load power consumption at 230 Vac, 5 Vdc, 12 Vdc, 15 Vdc, 24 Vdc output 0.3 W at 230 Vac, 36 Vdc, 48 Vdc output 0.5 W OUTPUT parameter conditions/description min typ max units 5 Vdc output 10,000 F 12 Vdc output 6,800 F 15 Vdc output 3,300 F capacitive load 24 Vdc output 2,200 F 36 Vdc output 1,000 F 48 Vdc output 470 F line regulation rated load 0.5 % 0% ~ 100%, 5 Vdc output 1 % load regulation 0% ~ 100%, other outputs 0.5 % hold-up time at 115 Vac 10 ms at 230 Vac 55 ms switching frequency 65 kHz temperature coefficient 0.03 %/C adjustability built in trim pot 10 % 5 Vdc output 2 % initial set point accuracy other outputs 1 % PROTECTIONS parameter conditions/description min typ max units 5 Vdc output, clamp, auto recovery 7.5 Vdc 12 Vdc output, clamp, auto recovery 19.2 Vdc 15 Vdc output, clamp, auto recovery 24 Vdc over voltage protection 24 Vdc output, clamp, auto recovery 38.4 Vdc 36 Vdc output, clamp, auto recovery 57.6 Vdc 48 Vdc output, clamp, auto recovery 60 Vdc over current protection auto recovery 110 160 % short circuit protection continuous, hiccup, auto recovery SAFETY & COMPLIANCE parameter conditions/description min typ max units input to ground, 1 min. <10mA 2,000 Vac isolation voltage input to output, 1 min. <10mA 4,000 Vac output to ground, 1 min. <10mA 1,250 Vac certified to 62368: IEC, EN, UL safety approvals designed to meet 60335: IEC, EN designed to meet 61558: IEC, EN safety class class I EMI/EMC CISPR 32/EN 55032 Class B, IEC 61000-3-2 Class A ESD IEC/EN 61000-4-2 Contact 6KV/Air 8KV perf. criteria A radiated immunity IEC/EN 61000-4-3 10 V/m perf. criteria A cui.com