Additional Resources: Product Page 3D Model date 03/09/2021 page 1 of 6 SERIES: VGS-200C DESCRIPTION: AC-DC POWER SUPPLY FEATURES UL/EN/IEC 62368 certified designed to meet IEC/EN 61558, IEC/EN 60335, and GB4943 system requirements short-circuit, over-current, over-voltage, over-temperature protections output adjustable via trimpot +/- 10% RoHS output output output power ripple efficiency 2 MODEL voltage current and noise typ range max max max typ (Vdc) (Vdc) (A) (W) (mVp-p) (%) VGS-200C-5 5 4.5~5.5 30.0 150.0 150 87.0 VGS-200C-12 12 10.2~13.8 17.0 204.0 150 87.5 VGS-200C-15 15 13.5~18.0 14.0 210.0 150 88.0 VGS-200C-24 24 21.6~28.8 8.8 211.2 150 88.5 VGS-200C-36 36 32.4~39.6 5.9 212.4 200 89.0 VGS-200C-48 48 43.2~52.8 4.4 211.2 200 89.5 Notes: 1. Ripple and noise are measured at 20 MHz BW with 47 uF aluminum electrolytic capacitor and 0.1 uF ceramic capacitor on the output. 2. Measured at 230 Vac. PART NUMBER KEY VGS-200C - XX - X Base Number A - with terminal cover Output Voltage B - with conformal coating cui.comAdditional Resources: Product Page 3D Model CUI Inc SERIES: VGS-200C DESCRIPTION: AC-DC POWER SUPPLY date 03/09/2021 page 2 of 6 INPUT parameter conditions/description min typ max units ac input, low voltage (switch in position of 115) 90 132 Vac voltage range ac input, high voltage (switch in position of 230) 180 264 Vac dc input, (switch in position of 230) 240 373 Vdc frequency range 47 63 Hz at 115 Vac 5 A current at 230 Vac 3 A at 115 Vac, cold start 60 A inrush current at 230 Vac, cold start 60 A no load power consumption at 230 Vac, 25 C 0.75 W OUTPUT parameter conditions/description min typ max units 5 V model 10,000 F 12 V model 4,000 F 15 V model 3,300 F capacitive load F 24 V model 1,500 36 V model 1,500 F 48 V model 470 F 5 V model, full load range 3 % initial set point acuracy 12 V model, full load range 1.5 % all other models, full load range 1 % line regulation rated load 0.5 % 5 V model, 0~100% load 2 % load regulation 12 V model, 0~100% load 1 % all other models, 0~100% load 0.5 % switching frequency 65 kHz at 115 Vac 12 ms hold-up time at 230 Vac 16 ms PROTECTIONS parameter conditions/description min typ max units over current protection auto recovery 110 185 % 5 V model, output shut down, latching 8.0 Vdc 12 V model, output shut down, latching 18.0 Vdc 15 V model, output shut down, latching 22.0 Vdc over voltage protection 24 V model, output shut down, latching 33.6 Vdc 36 V model, output shut down, latching 46.8 Vdc 48 V model, output shut down, latching 60.0 Vdc short circuit protection continuous, auto recovery, hiccup over temperature protection latching SAFETY & COMPLIANCE parameter conditions/description min typ max units input to output, 1 min, <10 mA 3,000 Vac isolation voltage input to ground, 1 min, <10 mA 2,000 Vac output to ground, 1 min, <5 mA 500 Vac certified to 62368: IEC/EN/UL designed to meet 60335: IEC/EN safety approvals designed to meet 61558: IEC/EN designed to meet 4943: GB conducted emissions CISPR32/EN55032 CLASS A radiated emissions CISPR32/EN55032 CLASS A cui.com