Additional Resources: Product Page 3D Model date 03/09/2021 page 1 of 7 SERIES: VGS-200D DESCRIPTION: AC-DC POWER SUPPLY FEATURES wide input range (85 ~ 305 VAC) available with conformal coating or terminal cover options active Power Factor Correction (PFC) certified to IEC/EN/UL 62368 designed to meet IEC/EN 60335 and GB4943 output over voltage, over current, over temperature, short circuit protection CISPR/EN55032 Class B radiated/conducted emissions RoHS output output output ripple efficiency 2 MODEL voltage current power and noise typ range max max typ typ (Vdc) (Vdc) (A) (W) (mVp-p) (%) VGS-200D-5 5 4.5~5.5 40.0 200.0 150 85 VGS-200D-12 12 11.4~12.6 16.7 200.4 150 88 VGS-200D-15 15 14.25~15.75 13.4 201.0 150 88 VGS-200D-24 24 22.8~25.2 8.4 201.6 150 90 VGS-200D-48 48 45.6~50.4 4.2 201.6 240 89 Notes: 1. Ripple and noise are measured at 20 MHz BW with 47 uF aluminum electrolytic capacitor and 0.1 uF ceramic capacitor on the output. 2. Measured at 230 Vac. PART NUMBER KEY VGS-200D - XX - X Base Number Output Voltage A - with terminal cover B - with conformal coating cui.comAdditional Resources: Product Page 3D Model CUI Inc SERIES: VGS-200D DESCRIPTION: AC-DC POWER SUPPLY date 03/09/2021 page 2 of 7 INPUT parameter conditions/description min typ max units ac input 85 305 Vac voltage range dc input 120 430 Vdc frequency range 47 63 Hz at 115 Vac 3.0 A current at 230 Vac 2.0 A at 115 Vac, cold start 35 A inrush current at 230 Vac, cold start 65 A no load power consumption at 230 Vac 1.0 W at 115 Vac, full load 0.98 power factor at 230 Vac, full load 0.95 OUTPUT parameter conditions/description min typ max units 5 V model 3,000 F 12 V model 4,000 F capacitive load 15 V model 3,300 F 24 V model 1,500 F F 48 V model 470 5 V model, full load range 2 % initial set point acuracy all other models, full load range 1 % line regulation rated load 0.5 % 5 V model at 230 Vac, 0~100% load 1 % load regulation all other models at 230 Vac, 0~100% load 0.5 % at 115 Vac, full load 8 ms hold-up time at 230 Vac, full load 8 ms PROTECTIONS parameter conditions/description min typ max units over current protection auto recovery 105 200 % 5 V model, auto recovery, hiccup 7.0 Vdc 12 V model, output shut down, latching 16.2 Vdc over voltage protection 15 V model, output shut down, latching 21.8 Vdc 24 V model, output shut down, latching 32.4 Vdc 48 V model, output shut down, latching 60.0 Vdc short circuit protection continuous, auto recovery, hiccup protection activation, full load 85 C over temperature protection protection deactivation 55 C SAFETY & COMPLIANCE parameter conditions/description min typ max units input to output, 1 min, <10 mA 4,000 Vac isolation voltage input to ground, 1 min, <10 mA 2,000 Vac output to ground, 1 min, <10 mA 500 Vac certified to 62368: IEC, EN, UL safety approvals designed to meet 60335: IEC, EN (excludes 5 V model) designed to meet 4943: GB conducted emissions CISPR32/EN55032 CLASS B radiated emissions CISPR32/EN55032 CLASS B harmonic current IEC/EN61000-3-2 CLASS A voltage flicker IEC/EN61000-3-3 ESD IEC/EN 61000-4-2 Contact 6KV/Air 8KV, perf. Criteria A cui.com