Additional Resources: Product Page 3D Model PCB Footprint datdatee 04/01/201304/01/2013 pagepage 1 of 41 of 4 SERIES: VHB100W DESCRIPTION: DC-DC CONVERTER FEATURES up to 100 W isolated output industry standard half brick package 4:1 input range (9~36 V, 18~75 V) single output from 3.3~48 V 1,500 V isolation over current, over temperature, over voltage, and short circuit protections remote on/off efficiency up to 89% RoHS input output output output ripple efficiency MODEL 1 voltage voltage current power and noise range max max max typ (Vdc) (Vdc) (A) (W) (mVp-p) (%) VHB100W-Q24-S3R3 9 ~ 36 3.3 20 66 100 81.5 VHB100W-Q24-S5 9 ~ 36 5 20 100 100 83.5 VHB100W-Q24-S12 9 ~ 36 12 8.3 100 150 85 VHB100W-Q24-S15 9 ~ 36 15 6.7 100 150 86.5 VHB100W-Q24-S24 9 ~ 36 24 4.17 100 240 86 VHB100W-Q24-S28 9 ~ 36 28 3.57 100 280 86 VHB100W-Q24-S48 9 ~ 36 48 2.08 100 480 85 VHB100W-Q48-S3R3 18 ~ 75 3.3 20 66 100 80.5 VHB100W-Q48-S5 18 ~ 75 5 20 100 100 86 VHB100W-Q48-S12 18 ~ 75 12 8.3 100 150 86.5 VHB100W-Q48-S15 18 ~ 75 15 6.7 100 150 87.5 VHB100W-Q48-S24 18 ~ 75 24 4.17 100 240 88 VHB100W-Q48-S28 18 ~ 75 28 3.57 100 280 88 VHB100W-Q48-S48 18 ~ 75 48 2.08 100 480 88 Notes: 1. ripple and noise are measured at 20 MHz BW with 10F tantalum capacitor and 1F ceramic capacitor across output PART NUMBER KEY VHB100W - QXX - SXX X Base Number Input Voltage Output Voltage Remote On/Off Controlblan = positive logic N = negative logic cui.comAdditional Resources: Product Page 3D Model PCB Footprint CUI Inc SERIES: VHB100W DESCRIPTION: DC-DC CONVERTER date 04/01/2013 page 2 of 4 INPUT parameter conditions/description min typ max units 9 24 36 Vdc operating input voltage 18 48 75 Vdc 24 V input 50 Vdc 1 surge voltage 48 V input 100 Vdc 24 V input 8.8 Vdc power up 48 V input 17 Vdc under voltage lockout 24 V input 8 Vdc power down 48 V input 16 Vdc 2 positive logic remote on/off filter PI type Notes: 1. 100 ms max 2. logic compatibility, open collector ref to -input Module ON, >3.5 Vdc or open circuit Module OFF, <1.8 Vdc OUTPUT parameter conditions/description min typ max units line regulation measured from high line to low line 0.2 % load regulation measured from full load to zero load 0.2 % voltage accuracy 1.5 % transient response 25% step load change 500 s 3 adjustability 10 % switching frequency 100% load, input voltage range 250 kHz temperature coefficient 0.03 %/C Notes: 3. trim-up: connect a resistor between the trim pin and -Sense trim-down: connect a resistor between the trim pin and +Sense PROTECTIONS parameter conditions/description min typ max units over voltage protection %Vo 115 140 % short circuit protection continuous current limit % nominal output current 110 140 % thermal shutdown case temp. 105 C SAFETY AND COMPLIANCE parameter conditions/description min typ max units input to output 1,500 Vdc isolation voltage input to case 1,500 Vdc output to case 1,500 Vdc isolation resistance 10 M isolation capacitance 1,500 pF safety approvals UL60950-1 RoHS compliant yes cui.com