Additional Resources: Product Page 3D Model date 05/11/2021 page 1 of 6 SERIES: VOF-65C DESCRIPTION: AC-DC POWER SUPPLY FEATURES universal input voltage range (85~264 VAC) 3 2 x 1.2 in (76.2 x 50.8 x 30 mm) class B EMI performance, meets CISPR32 / EN55032 output short circuit, overcurrent & overvoltage protection safety certified: IEC/EN/UL 62368 2 output output output ripple efficiency MODEL 1 voltage current power and noise min max max max typ (Vdc) (mA) (mA) (W) (mVp-p) (%) VOF-65C-S5 5 0 10000 50 150 80 VOF-65C-S9 9 0 6600 60 150 83 VOF-65C-S12 12 0 5420 65 150 85 VOF-65C-S15 15 0 4340 65 150 85 VOF-65C-S24 24 0 2710 65 150 87 VOF-65C-S48 48 0 1360 65 150 87 Notes: 1. At full load, nominal input, 20 MHz bandwidth oscilloscope, with 1 F ceramic and 10 F electrolytic capacitors on the output. 2. At 230 Vac input. 3. All specifications are measured at Ta=25C, humidity <75%, nominal input voltage, and rated output load unless otherwise specified. PART NUMBER KEY VOF-65C - SXX Base Number Output Voltage cui.comAdditional Resources: Product Page 3D Model CUI Inc SERIES: VOF-65C DESCRIPTION: AC-DC POWER SUPPLY date 05/11/2021 page 2 of 6 INPUT parameter conditions/description min typ max units 85 264 Vac voltage 100 370 Vdc frequency 47 63 Hz at 115 Vac 1600 mA current at 230 Vac 900 mA at 115 Vac 35 A inrush current at 230 Vac 50 A no load power consumption 0.5 W OUTPUT parameter conditions/description min typ max units 40,000 5 Vdc output models 12,000 9 Vdc output models 8,000 12 Vdc output models capacitive load F 15 Vdc output models 7,000 24 Vdc output models 1,500 48 Vdc output models 1,000 initial set point accuracy 2 % line regulation at full load 0.5 % load regulation from 5~100% load 1 % hold-up time at 230 Vac, full load 35 ms switching frequency 65 kHz temperature coefficient 0.02 %/C PROTECTIONS parameter conditions/description min typ max units output voltage clamp, auto recovery 7.5 5 Vdc output models 9 9 Vdc output models 16 over voltage protection 12 Vdc output models 20 Vdc 15 Vdc output models 24 24 Vdc output models 35 48 Vdc output models 60 over current protection hiccup, auto-recovery 120 300 % short circuit protection hiccup, continuous, auto-recovery SAFETY & COMPLIANCE parameter conditions/description min typ max units input to output electric strength test for 1 minute, isolation voltage 3,000 Vac leakage current <5 mA safety approvals IEC/UL/EN 62368-1 certified safety class Class II conducted emissions CISPR32/EN55032, Class B radiated emissions CISPR32/EN55032, Class B ESD IEC/EN61000-4-2, Contact 6KV, Perf. Criteria B radiated immunity IEC/EN61000-4-3 10V/m perf. Criteria A cui.com