Additional Resources: Product Page 3D Model PCB Footprint date 03/18/2013 pagepage 1 of 41 of 4 SERIES: VQE50W DESCRIPTION: DC-DC CONVERTER FEATURES up to 50 W isolated output industry standard quarter brick package 4:1 input range (9~36 V, 18~75 V) single output from 3.3~48 V 1,500 V isolation tantalum free capacitors used over current, over temperature, over voltage, and short circuit protections remote on/off very high efficiency up to 92% RoHS input output output output ripple and efficiency MODEL 1 voltage voltage current power noise range max max max typ (Vdc) (Vdc) (A) (W) (mVp-p) (%) VQE50W-Q24-S3R3 9 ~ 36 3.3 10 33 100 90.5 VQE50W-Q24-S5 9 ~ 36 5 10 50 100 91.5 VQE50W-Q24-S12 9 ~ 36 12 4.16 50 150 91.5 VQE50W-Q24-S15 9 ~ 36 15 3.33 50 150 91.5 VQE50W-Q24-S24 9 ~ 36 24 2.08 50 240 90 VQE50W-Q24-S48 9 ~ 36 48 1.04 50 480 88.5 VQE50W-Q48-S3R3 18 ~ 75 3.3 10 33 100 90 VQE50W-Q48-S5 18 ~ 75 5 10 50 100 92 VQE50W-Q48-S12 18 ~ 75 12 4.16 50 150 92 VQE50W-Q48-S15 18 ~ 75 15 3.33 50 150 91 VQE50W-Q48-S24 18 ~ 75 24 2.08 50 240 90.5 VQE50W-Q48-S48 18 ~ 75 48 1.04 50 480 89 Notes: 1. ripple and noise are measured at 20 MHz BW with 10F tantalum capacitor and 1F ceramic capacitor across output PART NUMBER KEY VQE50W - QXX - SXX X Base Number Input Voltage Output Voltage Remote On/Off Controlblan = positive logic N = negative logic cui.comAdditional Resources: Product Page 3D Model PCB Footprint CUI Inc SERIES: VQE50W DESCRIPTION: DC-DC CONVERTER date 03/18/2013 page 2 of 4 INPUT parameter conditions/description min typ max units 24 V input 9 24 36 Vdc operating input voltage 48 V input 18 48 75 Vdc 24 V input 50 Vdc surge voltage 100 ms max. 48 V input 100 Vdc 24 V input 8.8 Vdc power up 48 V input 17 Vdc under voltage lockout 24 V input 8 Vdc power down 48 V input 16 Vdc 1 positive logic remote on/off filter PI type Notes: 1. logic compatibility, open collector ref to -input Module ON, 3.5 ~ 75 Vdc or open circuit Module OFF, <1.2 Vdc 2. negative logic remote on/off available Module ON, <1.2 Vdc current limit, 110~165% nominal output Module OFF, 3.5 ~ 75 Vdc or open circuit OUTPUT parameter conditions/description min typ max units line regulation measured from high line to low line 0.2 % load regulation measured from full load to zero load 0.2 % voltage accuracy 1.5 % transient response 25% step load change 500 s external trim adj. range 10 % switching frequency 100% load, input voltage range 300 kHz temperature coefficient 0.03 %/C PROTECTIONS parameter conditions/description min typ max units over voltage protection %Vo 115 140 % short circuit protection continuous current limit % nominal output current 110 165 % thermal shutdown case temp. 110 C SAFETY AND COMPLIANCE parameter conditions/description min typ max units input to output 1,500 Vdc isolation voltage input to case 1,500 Vdc output to case 1,500 Vdc isolation resistance 10 M isolation capacitance 1,000 pF safety approvals UL 60950-1, CE RoHS compliant yes MTBF MIL-STD-217F, GB, 25C, full load TBD hours ENVIRONMENTAL parameter conditions/description min typ max units case operating temperature -40 105 C storage temperature -55 125 C humidity non-condensing 95 % cui.com