AA60S Series 60W Single AC/DC Power Module FEATURES Encapsulated compact AC-DC power supply Over Load and Over Voltage Protection 3 Mounting Package Versoin: - Solder pins for direct PCB mount - Screw terminal block for chassis mount - DIN-Rail Mount Universal Input voltage range 85-264 VAC, 47-440 Hz 3kVAC Isolatoin, Protection Class ll level UL/IEC/EN 60950-1 Certified , CE Marked UL508 Approval Lead free, RoHs Compliant 3 Year Product Warranty The AA60S series , isolated fully encapsulated 60W AC/DC power module with 3,000VAC isolation. With Universal input voltage 85-264VAC and International safety approvals, these power modules are ideal for applications in commercial and industrial electronic equipment. These isolated AC/DC converters are the latest offering from a world leader in power systems technology and manufacturing Delta Electronics, Inc. With creative design technology and optimization of component placement, these converters possess outstanding electrical and thermal performance, as well as extremely high reliability under highly stressful operating conditions. industrial electronic equipment. Model List Output Output Current Input Current Max. capacitive Efficiency Model Number Voltage Load (typ.) 115VAC, 60Hz Max. Max. Load No Load Max. Load VDC mA mA(typ.) mA(typ.) F % AA60S0500A 5.1 10,000 936 50 8000 79 AA60S1200A 12 5000 1060 50 3900 82 AA60S1500A 15 4000 1047 50 3300 83 AA60S2400A 24 2500 1035 50 1500 84 AA60S3600A 36 1666 1035 50 1000 84 AA60S4800A 48 1250 1035 50 680 84 Input Characteristics Parameter Model Min. Typ. Max. Unit Input Voltage Range 85 --- 264 VAC Input Frequency Range All Models 47 --- 63 Hz Input Voltage Range 120 --- 370 VDC 115VAC --- --- 30 A Inrush Current (Cold Start at 25 ) 230VAC --- --- 50 A DS AA60S 04082014 E-mail: DCDC delta.com.tw Output Characteristics Parameter Conditions Min. Typ. Max. Unit Output Voltage Accuracy --- 1.0 2.0 % Line Regulation Vin=Min. to Max. --- 0.2 1.0 % Load Regulation Iout=Min. to Max. --- 0.5 1.0 % %V of PP 5.1VDC Output Models --- 2.0 3.0 V o Ripple & Noise (20MHz) %V of PP Other Output Models --- 1.0 1.3 V o Minimum Load --- 10 --- %Inom. Over Voltage Protection Zener diode clamp --- 120 --- % of Vo Transient Response Deviation (Iout=100% to Iout=50%) 3 6 % Temperature Coefficient --- 0.02 --- %/ Overshoot --- --- 5 % Vout Foldback, auto-recovery Current Limitation 105 --- --- %Inom. (long term overload condition may cause damage) Short Circuit Protection Hiccup mode, indefinite (automatic recovery) General Characteristics Parameter Conditions Min. Typ. Max. Unit I/O Isolation Voltage Input to Output, 60 Seconds 3000 --- --- VACrms I/O Isolation Resistance 500 VDC 100 --- --- M Switching Frequency --- 100 --- KHz Hold-up Time --- 20 --- ms MTBF (calculated) MIL-HDBK-217F 25, Ground Benign 125,000 --- --- Hours EMC Emission Conducted and radiated EN 55011 class B, EN 55022 class B, FCC part 15 class B Performance Standard Specification Requirement Criteria EN61000-4-2 Air 8KV Cont. 4KV B EN61000-4-3 80~1000MHz, 10V/m 80% AM, 1KHz modulation A AC port 2KV DC, SL, TL 2KV not less than 1 EN61000-4-4 B min. EMC Immunity according EN61000-4-5 1.2/50S(8/20S) AC dif. 1KV DC 0.5KV B EN61000-6-1 0.15~80MHz, 10Vrms (functional earth ports EN61000-4-6 included) B 80% AM, 1KHz modulation EN61000-4-8 50Hz/60Hz, 30A/m A 30%, 10ms B EN61000-4-11 60%, 100ms, 95%, 5000ms C Protection Class II According IEC/EN 60536 cUL/UL 60950-1,IEC/EN 60950-1 Safety Approvals UL508 approval Input Fuse All Models Built-in Fuse 6A / 250VAC External Fuse (Recommended) 3A Slow Blow Type DS AA60S 04082014 E-mail: DCDC delta.com.tw