TECHINCAL DATASHEET
LYTE DIN Rail Power Supply
24V 480W 1 Phase / DRL-24V480W1A
Highlights & Features
Universal AC input voltage
Built-in constant current circuit for reactive loads
Up to 88.0% efficiency
Full power from -20C to +50C operation at 230Vac
@ 5,000 meters or 16,400 feet altitude
Built-in DC OK relay contact option available
Compliance to SEMI F47 @ 200Vac
Conformal coating on PCBAs to protect against common
dust and chemical pollutants
Safety Standards
CB Certified for worldwide use
Model Number: DRL-24V480W1A
Unit Weight: 1.30 kg (2.86 lb)
Dimensions (L x W x D): 123.6 x 85.5 x 128.5 mm
(4.87 x 3.37 x 5.06 inch)
General Description
Deltas Lyte DIN Rail Power Supply series is designed for cost sensitive users who need to fulfill essential features needed for many
general industrial applications, without compromising on quality and reliability. The convection-cooled Lyte series will operate
between -20C to +70C, with full rated power available from -10C to +50C at 230Vac. The overcurrent protection is designed to
operate in constant current mode, which makes the Lyte series suitable for inductive and capacitive load applications. The product is
certified according to safety standards IEC/EN/UL 60950-1 for Information Technology Equipment (ITE) and UL 508 for Industrial
Control Equipment (ICE). Electromagnetic radiated and conducted emissions are compliant to EN 55032, Class B; and, the product is
fully compliant for environmental protection requirements per RoHS Directive (EU) 2015/863.
Model Information
LYTE DIN Rail Power Supply
Model Number Input Voltage Range Rated Output Voltage Rated Output Current
DRL-24V480W1A 85-264Vac (120-375Vdc) 24Vdc 20.0A
Model Numbering
DR L 24V 480W 1 A
DIN Rail Product Type Output Voltage Output Power Single Phase Delta A Without DC OK Contact
Standard S With DC OK Relay Contact
L LYTE Series
All parameters are specified at 25C ambient and AC input unless otherwise indicated.
1
www.DeltaPSU.com (October 2019, Rev. 04)
TECHINCAL DATASHEET
LYTE DIN Rail Power Supply
24V 480W 1 Phase / DRL-24V480W1A
Specifications
Input Ratings / Characteristics
Nominal Input Voltage 100-240Vac
Input Voltage Range 85-264Vac
Nominal Input Frequency 50-60Hz
Input Frequency Range 47-63Hz
DC Input Voltage Range* 120-375Vdc
Input Current 5.4A typ. @ 115Vac, 2.7A typ. @ 230Vac
Efficiency at 100% Load 85% typ. @ 115Vac, 88% typ. @ 230Vac
Max Power Dissipation 0% load 5W @ 115Vac
4W @ 230Vac
100% load 50W @ 115Vac
40W @ 230Vac
Max Inrush Current (Cold Start) 40A typ. @ 115Vac, 80A typ. @ 230Vac
Power Factor at 100% Load > 0.95 @ 115Vac & 230Vac
Leakage Current < 1mA @ 264Vac
*Fulfills test conditions for DC input. Safety approval for DC input can be obtained upon request.
Output Ratings / Characteristics**
Nominal Output Voltage 24Vdc
Factory Set Point Tolerance 24Vdc 2%
Output Voltage Adjustment Range 22-28Vdc
Output Current 20.0A (480W max.)
Output Power 480W
Line Regulation < 0.5% (@ 85-264Vac, 100% load)
Load Regulation < 1.5% (0-100% load) @ > -10C to +70C
< 2.0% ( 0-100% load) @ -10C to -20C
PARD*** (20MHz) < 120mVpp @ 0C to +70C
< 240mVpp @ < 0C to -10C
< 360mVpp @ < -10C to -20C
Rise Time 100ms typ. @ nominal input (100% load)
Start-up Time 1,000ms typ. @ 115Vac & 230Vac (100% load)
Hold-up Time 10ms typ. @ 115Vac (100% load)
16ms typ. @ 230Vac (100% load)
Dynamic Response 10% (2400mVpp) @ 85-264Vac input, 0-50% load, 50-100%
(Overshoot & Undershoot O/P Voltage) load (Slew Rate: 0.1A/s)
Start-up with Capacitive Loads 8,000F Max
Functional DC OK Relay Contact 30V / 1A
The relay contact are normally ON (closed) when the output
(Vout) is greater than 90% of its rated value.
**For power de-rating from 40C to 70C @ 115Vac & 50C to 70C @ 230Vac, and Vin < 100Vac, see power de-rating on page 3.
***PARD is measured with an AC coupling mode, 5cm wires, and in parallel with 0.1F ceramic capacitor & 47F electrolytic capacitor.
All parameters are specified at 25C ambient and AC input unless otherwise indicated.
2