15W Ultra Slim Step Shape DIN Rail HDR-15 series Bauar t gep ruft Sicherheit egel ma ge od o s b e w a c g www. tuv. com ID 2000000000 UL60950-1 UL508 EN61558 IEC60950-1 Features Ultra slim design with 17.5mm( o ass LPS (Limited power source) / ooling by free air convection (working temperature:-30~+70C) DIN rail TS-35/7.5 or 15 mountable ED indicator for power on o File Name:HDR-15-SPEC 2017-08-0715W Ultra Slim Step Shape DIN Rail HDR-15 series SPECIFICATION MODEL HDR-15-5 HDR-15-12 HDR-15-15 HDR-15-24 HDR-15-48 DC VOLTAGE 5V 12V 15V 24V 48V RATED CURRENT 2.4A 1.25A 1A 0.63A 0.32A CURRENT RANGE 0 ~ 2.4A 0 ~ 1.25A 0 ~ 1A 0 ~ 0.63A 0 ~ 0.32A RATED POWER 12W 15W 15W 15.2W 15.4W RIPPLE & NOISE (max.) Note.2 80mVp-p 120mVp-p 120mVp-p 150mVp-p 240mVp-p OUTPUT VOLTAGE ADJ. RANGE 4.5 ~ 5.5V 10.8 ~ 13.8V 13.5 ~ 18V 21.6 ~ 29V 43.2 ~ 55.2V VOLTAGE TOLERANCE Note.3 2.0% 1.0% 1.0% 1.0% 1.0% LINE REGULATION 1.0% 1.0% 1.0% 1.0% 1.0% LOAD REGULATION 1.0% 1.0% 1.0% 1.0% 1.0% SETUP, RISE TIME 2000ms, 80ms/230VAC 2000ms, 80ms/115VAC at full load HOLD UP TIME (Typ.) 30ms/230VAC 12ms/115VAC at full load VOLTAGE RANGE 85 ~ 264VAC (277VAC operational ) 120 ~ 370VDC (390VDC operational ) FREQUENCY RANGE 47 ~ 63Hz INPUT EFFICIENCY (Typ.) 80% 85% 85.5% 86% 87% AC CURRENT (Typ.) 0.5A/115VAC 0.25A/230VAC INRUSH CURRENT (Typ.) COLD START 25A/115VAC 45A/230VAC 110 ~ 145% rated output power OVERLOAD Note.4 Protection type : Constant current limiting, recovers automatically after fault condition is removed PROTECTION 5.75 ~ 6.75V 14.2 ~ 16.2V 18.8 ~ 22.5V 30 ~ 36V 56.5~ 64.8V OVER VOLTAGE Protection type : Shut off o/p voltage, clamping by zener diode -30 ~ +70 (Refer toDerating Curv) WORKING TEMP. 20 ~ 90% RH non-condensing WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85, 10 ~ 95% RH non-condensing TEMP. COEFFICIENT 0.03%/ (0 ~ 50) RH non-condensing VIBRATION 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes Mounting: Compliance to IEC60068-2-6 OPERATING ALTITUDE 2000 meters OVER VOLTAGE CATEGORY ,According to EN61558, EN50178,altitude up to 2000 meters SAFETY STANDARDS UL60950-1, UL508, TUV EN61558-2-16, IEC60950-1 approved Design refer to EN50178,TUV EN60950-1 WITHSTAND VOLTAGE I/P-O/P:3KVAC ISOLATION RESISTANCE I/P-O/P:100M Ohms / 500VDC / 25/ 70% RH Standard Test Level / Note Parameter Conducted Class B EN55032(CISPR32) EMC EMISSION Radiated Class B EN55032(CISPR32) Harmonic Current EN61000-3-2 Class A Voltage Flicker EN61000-3-3 ------- SAFETY & EN55024, EN55035, EN61000-6-2, EN61204-3 EMC Test Level /Note (Note 5) Parameter Standard ESD EN61000-4-2 Level 3, 8KV air Level 2, 4KV contact, criteria A Radiated Susceptibility EN61000-4-3 Level 3, criteria A EN61000-4-4 EFT/Burest Level 3, criteria A EMC IMMUNITY Surge EN61000-4-5 Level 4,2KV/L-N, criteria A Conducted EN61000-4-6 Level 3, criteria A Magnetic Field EN61000-4-8 Level 4, criteria A 95% dip 0 .5 periods, 30% dip 25 periods, EN61000-4-11 Voltage Dips and interruptions 95% interruptions 250 periods MTBF 1166K hrs min. MIL-HDBK-217F (25) 17.5*90*54.5mm (W*H*D) OTHERS DIMENSION 78g 160pcs/13.5Kg/1.19CUFT PACKING NOTE File Name:HDR-15-SPEC 2017-08-07