TECHNICAL DATASHEET CliQ II DIN Rail Power Supply 24V 480W 3 Phase / DRP024V480W3B Highlights & Features Universal AC input voltage: 3 x 320Vac 600Vac (3-Phase) or 2 x 360Vac 600Vac (2-Phase) Power will not de-rate for the entire input voltage range Power Boost of 150% for 5 seconds and 200% for 2 seconds Full corrosion resistant aluminium chassis Conformal coating on PCBA to protect against chemical and dust pollutants Hazardous Locations approval to ATEX and Class I, Div 2 (DRP024V480W3BA) Safety Standards CB Certified for worldwide use Model Number: DRP024V480W3B Unit Weight: 1.35 kg (2.98 lb) Dimensions (L x W x D): 121 x 140 x 117.3 mm (4.76 x 5.51 x 4.62 inch) General Description The CliQ II 3-phase DIN rail power supply series offers output voltage of 24V. These products are encased in rugged yet lightweight full aluminium body that can withstand shock and vibration according to IEC 60068-2 standard. The series of 3-phase products can operate over a wide temperature range of -25C to +80C. These products also feature universal AC input voltage range for 3-phase from 320Vac to 600Vac or 2-phase from 360Vac to 600Vac, and the power will not de-rate throughout the entire range. Another great feature is the conformal coating on the PCBA which allows selected models to be certified to ATEX and Class I, Div 2 for use in hazardous locations. The design conforms to harmonic current emission IEC/EN 61000-3-2, Class A. Model Information CliQ II DIN Rail Power Supply Model Number Input Voltage Range Rated Output Voltage Rated Output Current DRP024V480W3B 3 x 320-600Vac (3-Phase) or 24Vdc 20.0A 2 x 360-600Vac (2-Phase) Model Numbering DR P 024V 480W 3 B DIN Rail Power Supply Output Voltage Output Power Three Phase CliQ II Series A - Metal Case, with Class I, Div 2 N - Metal Case, without Class I, Div 2 All parameters are specified at 25C ambient and AC input unless otherwise indicated. 1 www.DeltaPSU.com (December 2018, Rev. 03) TECHNICAL DATASHEET CliQ II DIN Rail Power Supply 24V 480W 3 Phase / DRP024V480W3B Specifications Input Ratings / Characteristics Nominal Input Voltage 3 x 400-500Vac Input Voltage Range 3 x 320-600Vac (3-Phase) or 2 x 360-600Vac (2-Phase) Nominal Input Frequency 50-60Hz Input Frequency Range 47-63Hz DC Input Voltage Range* 450-800Vdc Input Current < 1.00A 3 x 400Vac, < 0.75A 3 x 500Vac Efficiency at 100% Load > 91.0% 3 x 400Vac & 3 x 500Vac Max Inrush Current (Cold Start) < 50A 3 x 400Vac & 3 x 500Vac Power Factor at 100% Load > 0.95 3 x 400Vac, > 0.94 3 x 500Vac Leakage Current < 3.5mA 500Vac *Safety approval according to IEC/EN/UL 60950-1. Output Ratings / Characteristics Nominal Output Voltage 24Vdc Factory Set Point Tolerance 2% (initial set point tolerance from factory) Output Voltage Adjustment Range 24-28Vdc Output Current 20.0A (continuously operating at 24V) 30.0A (Power Boost for 5 seconds at 24V, refer to the details in the Functions section) 40.0A (Power Boost for 2 seconds at 24V, refer to the details in the Functions section) Output Power 480W (continuously operating at 24V) 720W (Power Boost for 5 seconds at 24V, refer to the details in the Functions section) 960W (Power Boost for 2 seconds at 24V, refer to the details in the Functions section) Line Regulation < 0.5% typ. ( 3 x 320-600Vac input, 100% load) Load Regulation < 1% typ. ( 3 x 320-600Vac input, 0-100% load) PARD (20MHz) < 150mVpp Rise Time < 100ms nominal input (100% load) Start-up Time < 1,000ms nominal input (100% load) Hold-up Time > 20ms 3 x 400Vac & 3 x 500Vac (100% load) Dynamic Response (Overshoot & Undershoot O/P Voltage) 5% 10-90% load Start-up with Capacitive Loads 10,000F Max All parameters are specified at 25C ambient and AC input unless otherwise indicated. 2 www.DeltaPSU.com (December 2018, Rev. 03)