TECHNICAL DATASHEET CliQ II DIN Rail Power Supply 24 V 240 W 2 Phase / DRP-24V240W2BN Highlights & Features Designed for single phase input 180-305 Vac (for L-N) or 2 of 3-Phase system 2 x 180-550 Vac (for L-L) or 254-780 Vdc Compact and corrosion resistant aluminium casing High Efficiency > 90.0% Conforms to harmonic current IEC/EN 61000-3-2, Class A Wide operating temperature range from -30C to +70C Built-in DC OK Contact Conformal coating on PCBAs to protect against common dust and chemical pollutants Certified according to IEC/EN/UL 62368-1 Safety Standards CB Certified for worldwide use Model Number: DRP-24V240W2BN Unit Weight: 0.81 kg (1.79 lb) Dimensions (L x W x D): 124 x 60 x 117 mm (4.88 x 2.36 x 4.61 inch) General Description The CliQ II DIN rail power supply series with a model offering two phase 2 x 180-550 Vac (for L-L) or single phase 180-305 Vac (for L- N) for 24 V/10 A output. The DRP-24V240W2BN has safety approvals for single phase and two phase input according to IEC/EN/UL 60950-1, IEC/EN/UL 62368-1 and UL 508 safety standards. The product features wide AC input voltage for single or two phase range. Such feature can protect the power supply from damage when user accidentally apply two phase input on the single phase power supply. Other advantages include reduced external input protection components and improved installation time since there is only two phase connection. The product performs under wide operating temperature from -30C to 70C with 2-Phase of 3- Phase application (for L-L). Conformal coating is applied on the PCBA to protect against common dust and chemical pollutant to withstand harsh industrial environments. Other major safety approvals included. Model Information CliQ II DIN Rail Power Supply Model Number Input Voltage Range Rated Output Voltage Rated Output Current DRP-24V240W2BN 2 x 180-550 Vac (2-Phase) 24 Vdc 10.0 A 180-305 Vac (Single Phase) 254-780 Vdc Model Numbering DR P 24V 240W 2 B N DIN Rail Power Supply Output Voltage Output Power Two Phase CliQ II Series N - Metal Case, without Class I, Div 2 and ATEX All parameters are specified at 25C ambient and AC x 2 input unless otherwise indicated. 1 www.DeltaPSU.com (September 2021, Rev. 06) TECHNICAL DATASHEET CliQ II DIN Rail Power Supply 24 V 240 W 2 Phase / DRP-24V240W2BN Specifications Input Ratings / Characteristics Nominal Input Voltage 2 x 200-500 Vac (2-Phase) 200-277 Vac (Single Phase) Input Voltage Range 2 x 180-550 Vac (2-Phase) 180-305 Vac (Single Phase) Nominal Input Frequency 50-60 Hz Input Frequency Range 47-63 Hz DC Input Voltage Range* 254-780 Vdc Input Current < 2.00 A 2 x 230 Vac, < 1.00 A 2 x 400 Vac Efficiency at 100% Load > 90.0% 2 x 400 Vac Max Power Dissipation 0% load < 8.5 W 2 x 200 Vac, < 9.5 W 2 x 500 Vac 100% load < 26.5 W 2 x 200 Vac, < 21.5 W 2 x 500 Vac Max Inrush Current (Cold Start) < 50 A 2 x 200 Vac & 2 x 500 Vac Leakage Current < 3.5 mA 500 Vac *Safety approval according to IEC/EN/UL 60950-1 and IEC/EN/UL 62368-1. Output Ratings / Characteristics** Nominal Output Voltage 24 Vdc Factory Set Point Tolerance 24 Vdc 2% Output Voltage Adjustment Range 24-28 Vdc Output Current 10.0 A (continuously operating at 24 V) 12.0 A (Power Boost for 3 seconds at 24 V, refer to the details in the Functions section) Output Power 240 W (continuously operating at 24 V) 288 W (Power Boost for 3 seconds at 24 V, refer to the details in the Functions section) Line Regulation < 0.5% ( 200-550 Vac input, 100% load) Load Regulation < 1.0% ( 200-550 Vac input, 0-100% load) PARD*** (20 MHz) < 150 mVpp -10C and above < 200 mVpp below -10C Rise Time < 100 ms nominal input (100% load) Start-up Time < 1,000 ms nominal input (100% load) Hold-up Time > 18 ms 2 x 230 Vac, > 30 ms 2 x 400 Vac (100% load) Dynamic Response 5% 180-550 Vac input, 0-100% load (Overshoot & Undershoot O/P Voltage) (Slew Rate: 0.1 A/s, 50% duty cycle 5Hz) Start-up with Capacitive Loads 10,000 F Max Functional DC OK Relay Contact 30 V / 1 A Max The relay is usually closed when the output is normal **For power de-rating from 50C to 70C, see power de-rating on page 3. ***PARD is measured with an AC coupling mode, 5cm wires, and in parallel with 0.1 F ceramic capacitor & 47 F electrolytic capacitor. All parameters are specified at 25C ambient and AC x 2 input unless otherwise indicated. 2 www.DeltaPSU.com (September 2021, Rev. 06)