TECHNICAL DATASHEET Medical AC-DC Enclosed Power Supply 24V 200W 2x4 High Density MDS-200ADB24 AA MDS-200ADB24 AA Highlights & Features Safety Approvals to IEC 60601-1 3.1rd ed. & IEC 60950-1 Compliant with IEC 60601-1-2 4th Ed. Requirements 2.5 x 4.5 x 1.8 Package Power Good Signal up to 800K Hours MTBF up to 120W convection, 200W forced air Safety Standards CB Certified for worldwide use Model Number: MDS-200ADB24 AA Unit Weight: 345 g (0.762 lb) Dimensions (W x L x H): 64.7x113.9x44.7 mm (2.5 x 4.5 x 1.8 inch) General Description The MDS-200ADB24 AA enclosed power supply comes with universal AC input range from 90Vac to 264Vac. Other features include low leakage, Type BF Patient Access Leakage Currents, and electric shock protection compliance with 2 x MOPP requirements. The MDS-200ADB24 AA is certified for EMC standards according to EN 55011for industrial, scientific and medical (ISM) radio-frequency equipment and, EN 55022 for Industrial Technology Equipment (ITE) radio-frequency equipment. In addition, only recognized Japanese capacitors are used to ensure long product life. The MDS-200ADB24 AA comes with both medical and ITE safety approvals, including UL/CE/CCC (5000meters), and CB certification. Designs are compliant with RoHS Directive 2011/65/EU for environmental protection. Model Information Model Number Input Voltage Output Voltage Convection Current Output Forced Air Current Output MDS-200ADB24AA 90-264Vac 24Vdc 0-5A 0-8.33A* *With 5.5CFM forced air Model Numbering MDS 200 A D B 24 AA Delta Medical power Max wattage in the Family Code Product Type Input Type Code Output Voltage Revision code product Series. Supply D: Enclosed B: 3pin Class I 24 for 24V Maybe lower at some A Z voltage. 200200W All parameters are specified at 25C ambient unless otherwise noted. 1 (November 2018, Rev. 03) TECHNICAL DATASHEET Medical AC-DC Enclosed Power Supply 24V 200W 2x4 High Density MDS-200ADB24 AA Specifications Input Ratings / Characteristics Nominal Input Voltage 100-240Vac Input Voltage Range 90-264Vac Nominal Input Frequency 50-60Hz Input Frequency Range 47-63Hz Input Current(max) 2.5A Input Surge Voltage (max) 300Vac for 100ms Full load Efficiency (typ.) 92% 115Vac/60Hz 93% 230Vac/50Hz, Reference Fig.1 Standby Power (max) 0.5W 115Vac/60Hz, 230Vac/50Hz Inrush Current (max) 60A 230Vac, cold start Input-PE(protective earth) leakage current(max) 0.1mA NC, 0.3mA SFC1) Output-PE(protective earth) leakage current for Type BF application (max) 0.1mA NC, 0.5mA SFC 1) Power Factor (min) 0.95 115V/50Hz, 230V/50Hz, full load 1) NC: normal condition, SFC: single fault condition Leakage Current Input-PE Leakage Current 100Vac/ 60Hz (Typ) 264Vac/ 60Hz (Typ) Delta Limit IEC60601-1 Limit Normal Condition 19.5uA 45.0uA 100uA max 5000uA max Single Fault Condition 44.8uA 153.0uA 300uA max 10000uA max Output-PE Leakage Current for Type BF application Normal Condition 38.3uA 81.5uA 100uA max 100uA max Single Fault Condition 43.4uA 129.4uA 500uA max 500uA max 100 90 115Vac 80 230Vac 70 60 50 25% 50% 75% 100% Output Load Fig.1 Efficiency versus output load All parameters are specified at 25C ambient unless otherwise noted. 2 (November 2018, Rev. 03) Efficiency (%)