TECHNICAL DATASHEET PMT2 Panel Mount Power Supply PMT2 50 W series / PMT- V50W2B PMT2 Highlights & Features Household appliance approvals according to IEC/EN 60335- 1, IEC/EN 61558-1 and IEC/EN 61558-2-16 Universal AC input voltage range No load power consumption <0.3 W Low profile design : 29 mm height OVC III, Pollution Degree 3 Wide operating temp -30C ~70C (Support -40C cold start) Conforms to harmonic current IEC/EN 61000-3-2, Class A High MTBF > 700,000 hrs per Telcordia SR-332 Safety Standards CB Certified for worldwide use Model Number: PMT-V50W2B Unit Weight: 0.176 kg (0.389 lb) Dimensions (L x W x H): 99 x 82 x 29 mm (3.9 x 3.23 x 1.14 inch) General Description nd PMT 2 generation (PMT2) power supplies is designed in a low 29 mm profile and accepts universal AC input. The highly efficient convection cooling construction can operate from -30C to 70C. The single output model is competitively priced for general industrial and ITE applications. It complies to major safety approvals such as IEC/EN 60335-1, IEC/EN 61558-2-16, IEC 60950-1 & IEC/EN/UL 62368-1. Model Information PMT2 Panel Mount Power Supply Model Number Input Voltage Range Rated Output Voltage Rated Output Current PMT-12V50W2B 90-264 Vac 12 Vdc 4.2 A PMT-15V50W2B 15 Vdc 3.4 A PMT-24V50W2B 24 Vdc 2.2 A PMT-30V50W2B 30 Vdc 1.7 A 36 Vdc 1.45 A PMT-36V50W2B PMT-48V50W2B 48 Vdc 1.1 A Model Numbering CC code PM T V 50W 2 B Panel Product Type Output Voltage Output Single Phase Family Code: B Connector Type Blank Without Mount Power with Low Profile connector cover & T Enclosed 12 12 V With No PFC A Terminal Block coating 15 15 V B With single side 24 24 V 1 coating* 30 30 V C With connector 36 36 V cover + single side 1 coating* 48 48 V *1 : 12 V / 24 V models only All parameters are specified at 25C ambient and nominal AC input unless otherwise indicated. 1 www.DeltaPSU.com (July 2021, Rev. 08) TECHNICAL DATASHEET PMT2 Panel Mount Power Supply PMT2 50 W series / PMT- V50W2B Specifications PMT-12V50W2B PMT-15V50W2B PMT-24V50W2B PMT-30V50W2B PMT-36V50W2B PMT-48V50W2B Model Number Input Ratings / Characteristics Nominal Input Voltage 100-240 Vac Input Voltage Range 90-264 Vac Nominal Input Frequency 50-60 Hz Input Frequency Range 47-63 Hz Input Current 0.95 A typ. 115 Vac, 0.6 A typ. 230 Vac Efficiency at 100% Load 230Vac 85.0% typ. 87.0% typ. 88.0% typ. 88.0% typ. 89.0% typ. 88.5% typ. No Load Power Consumption < 0.3 W 230 Vac Max Inrush Current (Cold Start) 45 A typ. 230 Vac Leakage Current < 0.5 mA 240 Vac 2 Output Ratings / Characteristics* Nominal Output Voltage 12 Vdc 15 Vdc 24 Vdc 30 Vdc 36 Vdc 48 Vdc Factory Set Point Tolerance 12 Vdc 1% 15 Vdc 1% 24 Vdc 1% 30 Vdc 1% 36 Vdc 1% 48 Vdc 1% Output Voltage Adjustment Range 10.8-13.2 Vdc 13.5-16.5 Vdc 21.6-26.4 Vdc 27.0-33.0 Vdc 32.4-39.6 Vdc 43.2-52.8 Vdc Output Current 4.2 A 3.4 A 2.2 A 1.7 A 1.45 A 1.1 A Output Power 50.4 W Max. 51 W Max. 52.8 W Max. 51 W Max. 52.2 W Max. 52.8 W Max. Line Regulation 0.5% ( 115 Vac & 230 Vac input) Load Regulation 0.5% ( 115 Vac & 230 Vac input) 3 PARD* (20MHz) < 120 mVpp 0C to 70C < 150 mVpp 0C to 70C < 200 mVpp 0C to 70C 360 mVpp typ. -30C to 0C 450 mVpp typ. -30C to 0C 600 mVpp typ. -30C to 0C Rise Time 30 ms typ. 115 Vac & 230 Vac Start-up Time 1,000 ms typ. 115 Vac 500 ms typ. 230 Vac Hold-up Time 12 ms typ. 115 Vac, 60 ms typ. 230 Vac Dynamic Response 10% 115 & 230 Vac input, 10-100% load (Slew Rate: 2.5 A/S, 50% duty cycle 5 Hz & (Overshoot & Undershoot O/P 10 KHz) Voltage) Start-up with Capacitive Loads 8,000F Max 8,000F Max 8,000F Max 470uF Max 470uF Max 470uF Max *2 For power de-rating from > 50C to 70C, see power de-rating on page 3. *3 PARD is measured with an AC coupling mode, and in parallel to end terminal with 0.1F ceramic capacitor & 47F electrolytic capacitor. PSU need to burn in > 5 minutes when AMB 0 All parameters are specified at 25C ambient and nominal AC input unless otherwise indicated. 2 www.DeltaPSU.com (July 2021, Rev. 08)