The SmartServer is a versatile smart SmartServer 2.0 energy manager that connects control The Smart Way to Save devices to IP-based applications such Energy and Lower Operating Costs as enterprise energy management, demand response programs, street light management systems, and high-value remote asset management programs. The server not only allows you to access, control, and monitor electronic devices, but also lets you use data intelligently to save energy, improve operations, and lower maintenance costs. Easy to deploy and manage, and capable of both local and remote control, the SmartServer offers unparalleled flexibility. Use it as a standalone server, or integrate it with the control system of your choice. With built-in drivers for industry-standard protocols like Echelons Lno Wskro technology, Web services SOAP/XML, Modbus, M-Bus, digital I/O, and pulsecount input, and custom driver support for everything else, the SmartServer offers unprecedented connectivity at no extra cost. FEATURES Building Energy Management can create custom Web pages by 14908-1 (LONWORKS) with built-in Building Energy Management (BEM) editing simple Web page mark-up with LONWORKS transceiver. Edition provides a robust, highly any standard Web authoring tool. Modbus RTU with built-in RS-485 reliable, and low-cost solution for Serial and Telnet console interface for transceiver. monitoring energy usage from multiple advanced configuration. Modbus TCP (Modbus TCP/IP) with energy meters and forwarding energy Programmatic Interfaces built-in Ethernet interface, optional data to the SeriousEnergy Manager Web services using SOAP/XML. internal analog modem, or external that collects and analyzes data from GSM/GPRS modem. Standard WSDL file suitable for .NET each meter and presents an energy and Java Web services integration. M-Bus with built-in RS-485 transceiver dashboard Web-based interface. and optional M-Bus translator. LNS Remote Network Interface (RNI) Templates available for all editions for for local or remote connection to LNS Custom drivers using built-in Ethernet, easy connection to a wide variety of or OpenLDV applications including the RS-232, and RS-485 interfaces. energy meters. LonMaker Integration Tool, supporting Built-in SmartServer Apps Street Light System Support the following limits: Scheduling: time of day, day of week, Power line (PL) editions have street - 32,768 address table entries date, and sunrise/sunset relative. light segment control built-in, with - 255 outgoing transactions support for mesh repeating for street Alarming: data point health and value - 3,000 dynamic network variables light controllers using both power line monitoring flexible reporting. HTTP and HTTPS interfaces for Web and RF segments, with RF segments Data logging with automatic transfers browser-based interfaces. created with the Echelon Street Light to historical data repositories Bridge. SmartServer API for custom apps Meter reading. User Interfaces Network and Device Interfaces Network integration with customizable Built-in Web pages for setup, network IP via built-in 10/100BaseT Ethernet data type translation, analog functions, installation commissioning, scheduling, interface, optional internal 56K V.90 and case logic for converting, splitting, alarming, data logging, and network analog modem, or external GSM/GPRS and merging structured data points. integration. or 3G modem. Built-in Web pages for configuring and The included i.LON Vision 2.0 Web TP/FT-10 free topology twisted pair using all applications. Authoring Tool lets you create custom or PL-20 C-band power line ISO/IEC Web pages quickly and easily or you Unified data model provides easy Standalone network installation mode IP-852 Routing access to all your data regardless supports up to 200 devices and ISO/IEC 14908-4 (IP-852) routing of manufacturer or communication ensures field personnel can get a site included with the Professional and protocol. up and running quickly, without ad- BEM Editions, and available as an ditional installation tools. option for the Standard Edition. Up to 1,000 data points can be denfi ed for use by built-in and custom Automatic device discovery and instal- IP-852 lets you use any IP network as applications. lation reduces time spent installing, a backbone for a LONWORKS network. replacing, and upgrading devices. Programmatic SOAP/XML interface IP-852 channel can include an LNS for remote application access to all Configure, commission, test, upgrade, Turbo Edition Server and up to 255 applications. and replace devices. i.LON SmartServers with IP-852 routing, i.LON 600 servers, third-party Windows PC Apps Read and write any network variable or IP-852 routers, and LNS Turbo Edition Rapid site deployment lets you quickly configuration property. clients. replicate and deploy a site design and Create network connections in LNS configuration to a new site. IP-852 channel supports thousands mode. of packets per second for high- Remote upgradability lets you easily Launch plug-ins to configure devices in performance monitoring and control. update multiple remote sites to new LNS mode. SmartServer versions. Standards-based Protocols Built-in RNI supports remote OpenLDV IP local and wide area networking pro- Remote backup and restore features and LNS applications. tocols and Internet standards include help you easily recover from hardware Built-in LonScanner interface TCP, IPv4, IPv6, PPP, CHAP, PAP, DHCP, failures. supports the LonScanner Protocol DNS, FTP, ICMP, MD5, SMTP, SNMP, Data log historian automatically Analyzer. SNTP, HTTP, HTTPS, and SSL. receives and extracts data logs from Visualization Additional IP application protocols: multiple sites. Create custom displays with i.LON HTML, XML, SOAP, and DIME. LNS SOAP interface for seamless syn- Vision 2.0 (no other software required) Dynamic IP addresses supported chronization between a SmartServer or use the Web authoring tool of your using the dynamic DNS service from and an LNS Server. choice. DynDNS. BEM Edition includes wizards that Built-in design elements (such as a NAT is supported. configure and install SmartServers slider, gauge, navigation tree, and and supported BEM submeters, and ISO/IEC 14908-1 Control Network menu) help you create displays quickly. automate connection to the SeriousEn- Protocol. Trend graphs for real-time and histori- ergy Manager energy management ISO/IEC 14908-2 Free Topology cal tracking of data point values. platform. Twisted Pair (FT versions). Trend graphs available on both built-in Custom Apps ISO/IEC 14908-3 Power Line configuration pages and custom Web Support for custom apps included with (PL versions). pages. the Professional and BEM Editions ISO/IEC 14908-4 Control Network IP Trend graphs can show both scalar and and is available as an option for the Tunneling Protocol (optional IP-852 structured data such as a temperature Standard Edition. routing). value with an alarm condition. C/C++ programming environment. Browse built-in and custom Web pages SPECIFICATIONS Eclipse IDE lets you quickly and easily with Internet Explorer or Firefox. develop and deploy SmartServer apps. PC Requirements Hardware I/O Minimum Requirements for the Web page localization tool. 2 optically isolated digital inputs. SmartServer 2.0 Requires separate purchase of 2 high-voltage, high-current SPST Pentium III 1.3GHz, 768MB RAM, DVD- SmartServer 2.0 Programming Tools. relay outputs. ROM drive, 100MB of free disk space. LONWORKS Network Installation 2 S0 impulse meter inputs for super- Minimum Requirements for Echelon Two LONWORKS network installation vising electric, gas, and water impulse Enterprise Services modes: LNS mode and Standalone meters. Pentium IV 1.5GHz, 1GB RAM, DVD- mode. ROM drive, 270MB of free disk space. Hardware inputs and outputs are LNS mode provides seamless inte- exposed as standard data points. Minimum Requirements for the gration with the market-leading LNS SmartServer Programming Tools Hardware inputs and outputs can be Server, the operating system for Pentium IV 1.5GHz, 1GB RAM, DVD- scaled and converted to and from LONWORKS networks. ROM drive, 250MB of free disk space. appropriate units. LNS mode works with LNS tools Hardware outputs can be triggered Operating Systems such as the LonMaker Integration by network events. Windows 7 (64-bit* and 32-bit versions), Tool standalone LNS Server for the Windows Vista (32-bit version), or SmartServer is available if an LNS tool Windows XP *Note: the SmartServer is not available.