Product Information

BD 5987.02/001 AC 50/60HZ 230V

BD 5987.02/001 AC 50/60HZ 230V electronic component of Dold & Soehne

Datasheet
RELAY, SAFETY, DPST, 230VAC, 5A

Manufacturer: Dold & Soehne
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges



Price (USD)

1: USD 355.9824 ea
Line Total: USD 355.98

0 - Global Stock
MOQ: 1  Multiples: 1
Pack Size: 1
Availability Price Quantity
0 - WHS 1


Ships to you between Fri. 24 May to Thu. 30 May

MOQ : 1
Multiples : 1
1 : USD 557.6254

     
Manufacturer
Product Category
Coil Voltage
IP Rating
Product Range
Contact Current
Contact Voltage Ac Nom
Contact Voltage Dc Nom
Contact Configuration
Contact Material
Relay Terminals
Relay Mounting
Approvals Standards
Svhc
Approval Bodies
Coil Voltage Vac Nom
Contact Current Ac Max
Contact Current Max
Contact Voltage Ac Max
External Depth
External Height
External Length / Height
External Width
Height
Mounting Type
Operating Temperature Max
Operating Temperature Min
Switch Current Max
Switching Current Max
Type
LoadingGif

Notes:- Show Stocked Products With Similar Attributes.
Image Description
IK 8800.11 AC 50HZ 230V electronic component of Dold & Soehne IK 8800.11 AC 50HZ 230V

RELAY, SPDT, 230VAC, 16A
Stock : 0

MK 9163N.12/110 ATEX AC/DC 24V electronic component of Dold & Soehne MK 9163N.12/110 ATEX AC/DC 24V

RELAY, THERMISTOR, MOTOR PROTECTION
Stock : 0

MK 9151.11 2 - 450K - OHM DC 24V electronic component of Dold & Soehne MK 9151.11 2 - 450K - OHM DC 24V

RELAY, LEVEL SENSING
Stock : 0

MK 7850N.82/200  AC/DC12-240V electronic component of Dold & Soehne MK 7850N.82/200 AC/DC12-240V

TIME DELAY RELAY, DPDT, 300H, 230VAC
Stock : 0

BD 5935.48   DC 24V electronic component of Dold & Soehne BD 5935.48 DC 24V

RELAY, SAFETY, 3NO, SPST-NC, 250VAC, 5A
Stock : 0

BD 5936.17 AC 50/60HZ 230V electronic component of Dold & Soehne BD 5936.17 AC 50/60HZ 230V

RELAY, SAFETY, DPST-NO, NC, 230VAC, 5A
Stock : 0

BG 5924.48 AC/DC 24V electronic component of Dold & Soehne BG 5924.48 AC/DC 24V

RELAY, SAFETY, 3NO, SPST-NC, 230VAC, 5A
Stock : 0

BN 5983.53 DC 24V electronic component of Dold & Soehne BN 5983.53 DC 24V

RELAY, SAFETY, 3NO, SPST-NC, 230VAC, 5A
Stock : 0

BD 5987.02/001 DC  24V electronic component of Dold & Soehne BD 5987.02/001 DC 24V

RELAY, SAFETY, DPST, 230VAC, 5A
Stock : 0

IK 8701.12 AC 50HZ 230V electronic component of Dold & Soehne IK 8701.12 AC 50HZ 230V

RELAY, DPDT, 230VAC, 16A
Stock : 0

Image Description
C500CE241 electronic component of Omron C500CE241

Safety Relays 24PIN Con SOLDERTYPE
Stock : 1

2904951 electronic component of Phoenix Contact 2904951

Safety Relays PSR-MS25-1NO- 1DO-24DC-SC
Stock : 11

SP10-ETL01 electronic component of Omron SP10-ETL01

INPUT SIMULATOR
Stock : 1

56.OA03.3253C electronic component of Altech 56.OA03.3253C

Safety Relays OA5603,32V, 5NO/3NC
Stock : 1

YS1T-RHA38F21PD electronic component of Idec YS1T-RHA38F21PD

Electromechanical Relay DIN Rail Thermal Overload Relay
Stock : 1

SR6ZB024 electronic component of TE Connectivity SR6ZB024

TE Connectivity Schrack Safety Relays 4PST-NODPST-NC 8A 24VDC SAFETY RELAY
Stock : 1

SR6ZA730 electronic component of TE Connectivity SR6ZA730

RELAY, SAFETY, 3PST-NO, NC, 250VAC, 8A
Stock : 0

TK-E5-65-95 electronic component of Fuji TK-E5-65-95

Electromechanical Relay 5A (68x106x105)mm Bracket Thermal Overload Relay
Stock : 0

8951.2N electronic component of Altech 8951.2N

Safety Relays RM2G1, 1 Channel Safety relay
Stock : 1

J73KN-AM-22 electronic component of Omron J73KN-AM-22

Safety Relays Aux Contact Block 2NO+2NC
Stock : 0

Safety technique Emergency stop module BD 5987 safemaster BD 5987.02: According to EC Directive for machines 98/37/EG According to IEC/EN 60204-1 Safety category 4 according to EN 954-1 Output: 2 NO contacts for AC 250 V Gold-plated contacts to switch small loads (input for PLC) 1-channel or 2-channel connection Line fault detection at On pushbutton Operating state display LED displays for channels 1 and 2 Overvoltage and short circuit protection 2 Wire connection: also 2 x 1,5 mm stranded ferruled (isolated), DIN 46 228-1/-2/-3/-4 or 2 2 x 2,5 mm stranded ferruled DIN 46 228-1/-2/-3 Width 45 mm Fucntion diagram BD 5987.--/001: as BD 5987.02 but Optionally automatic On function when operating voltage is applied or after activation by the On pushbutton Pushbutton Optionally cross fault detection in emergency stop circuit On Emergency- Approvals and marking stop (Off) * * K2 ET Canada Canada / USA * see variants * Short-circuit detection K3 at the On pushbutton Applications M 6742 Protection of people and machines Emergency stop circuits on machines Block diagram Monitoring of safety gates Indication A1(+)A2(-) S33 S33 S33 PE(-) Y2 S12 S12 S22 13 23 33 LED power supply: on when operating voltage present LED K2: on when supply on K2 LED K3: on when supply on K3 overvoltage and short- monitoring K2 K3 K2 circuit protection logic Notes & K1 Line fault detection at the On pushbutton: The output contacts cannot be closed if the On pushbutton is already K1 K2 K3 24V closed before the voltage is applied to S12, S22 (also in the event of a line K3 fault at the On pushbutton). power A line fault at the On pushbutton which occurs after activation of the device is recognized when switching- on takes place again and closing of the output contacts is then prevented. If a line fault occurs at the On pushbutton after the voltage is already present at S12, S22 undesired activation will take place, because this line S34 Y1 S23 14 24 34 fault does not differ from the normal closing function. Circuit diagrams A1 PE A1 A1 S21 13 23 13 23 S22 S33 Y1 Y2 13 23 S12 S22 S23 S33 (+) (+) (-) (+) /PE A1 13 23 A1 Y1 13 23 A1 X5 13 23 S12 S12 T33 K2 S22 K2 S22 K2 S33 S33 T34 K3 S34 K3 S34 K3 A2 Y2 PE 14 24 A2 X6 PE 14 24 A2 14 24 A2 A2 A2 14 24 T33 T34 14 24 S12 S12 S33 S33 S34 14 24 S12 S33 X5 X6 S34 (-) (-) (-) M7377 b M7375 b M7376 b BD 5987.02 BD 5987.02/001 BD 5987.02/101 A1 S21 A1 S21 A1 13 23 S12 S22 S23 S33 13 21 S12 S22 S23 S33 13 23 T12 PE T22 S23 T11 (+) (+) /PE (+) /PE A1 X5 13 23 33 A1 X5 13 21 A1 T11 13 23 33 S12 S12 T12 S22 K2 S22 K2 T22 K2 S33 K1 S33 T33 K1 S34 K3 S34 K3 T34 K3 A2 X6 PE 14 24 34 A2 X6 PE 14 24 34 A2 X6 PE 14 22 A2 A2 A2 14 24 33 34 X5 X6 S34 14 24 33 34 T33 X6 T34 14 22 S12 S33 X5 X6 S34 (-) (-) (-) M7378 b M7379 c M7380 b BD 5987.03/001 BD 5987.03/021 BD 5987.16/001 All technical data in this list relate to the state at the moment of edition. We reserve the right for technical improvements and changes at any time. BD 5987 / 08.05.06 e 1 0221553 M6758 aNotes Technical data 6 The gold-plated contacts of the BD 5987 mean that this module is also Mechanical life: 10 x 10 switching cycles suitable for switching small loads of 1 mVA ... 7 VA, 1 mW ... 7 W in the General data range 0,1 ... 60 V, 1 ... 300 mA. The contacts also permit the maximum switching current. However, since the gold plating will be burnt off at this Operating mode: Continuous operation current level, the device is no longer suitable for switching small loads Temperature range: - 15 ... + 55C after this. at max. 90 % humidity The PE terminal permits operation of the device in IT systems with Clearance and creepage insulation monitoring and also serves as a reference point for testing the distances control voltage. The internal short-circuit protection will be bridged on DC overvoltage category / devices, if the protective ground is connected to terminal PE. contamination level: 4 kV / 2 IEC 60 664-1 One or more extension modules BN 5989 or external contactors with EMC positively-driven contacts may be used to multiply the number of contacts Electrostatic discharge: 8 kV (air) IEC/EN 61 000-4-2 of the emergency stop module BD 5987. HF irradiation: 10 V / m IEC/EN 61 000-4-3 For automatic restart: Fast transients: 2 kV IEC/EN 61 000-4-4 S22 must be connected before S12. S12 initiates the automatic restart. Surge voltages With manual restart it is not necessary to follow this order. between wires for power supply: 1 kV IEC/EN 61 000-4-5 ATTENTION - AUTOMATIC START between wire and ground: 2 kV IEC/EN 61 000-4-5 According to IEC/EN 60 204-1 part 9.2.5.4.2 it is not Interference suppression: Limit value class B EN 55 011 allowed to restart automatically after emergency stop. Degree of protection: Housing: IP 40 IEC/EN 60 529 Therefore the machine control has to disable the Terminals: IP 20 IEC/EN 60 529 automatic start after emergency stop. Housing: Thermoplastic with V0 behaviour according to Ul subject 94 Technical data Vibration resistance: Amplitude 0,35 mm IEC/EN 60 068-2-6 frequency 10 ... 55 Hz Input Climate resistance: 15 / 055 / 04 IEC/EN 60 068-1 Terminal designation: EN 50 005 Nominal voltage U : AC 24, 48, 110, 127, 230, 240 V 2 N Wire connection: 1 x 4 mm solid or DC 24 V 2 1 x 2,5 mm stranded ferruled (isolated) Voltage range: AC 0,8 ... 1,1 U N or at 10% residual ripple: DC 0,9 ... 1,2 U 2 N 2 x 1,5 mm stranded ferruled (isolated) at 48% residual ripple: DC 0,8 ... 1,1 U N DIN 46 228-1/-2/-3/-4 or Nominal consumption: approx. 5,5 VA 2 2 x 2,5 mm stranded ferruled Nominal frequency: 50 / 60 Hz DIN 46 228-1/-2/-3 Control voltage at S33: DC 24 V Wire fixing: Plus-minus terminal scews Control current M3.5 box terminal with wire protection BD 5987.02: typ. DC 55 mA Mounting: DIN rail IEC/EN 60 715 BD 5987.02/001: typ. DC 45 mA Weight: 450 g Minimum voltage at terminals S12, S22: DC 21 V with activated device Dimensions Recovery time: 0,5 s after release of the emergency stop pushbutton Width x height x depth: 45 x 74 x 121 mm Output Standard type Contacts BD 5987.02/001 DC 24 V BD 5987.02: 2 NO contacts Article number: 0040954 stock item BD 5987.16: 1 NO contact, 1 NC contact Output: 2 NO contacts The NO contacts are safety contacts. Optionally automatic On function when operating voltage is applied ATTENTION The NC contacts 21-22 or after activation by the On pushbutton and the NO contact 33-34 can only Nominal voltage U : DC 24 V N be used for monitoring. Width 45 mm Operate time: max. 100 ms BD 5987.02/001: with automatic restart approx. 1 s Release time Opening in secondary circuit (S12-S22): 50 ms 25 % Opening in supply circuit BD 5987.02: 350 ms 50 % BD 5987.02/001: 120 ms 50 % Contact type: relay, positively-driven Nominal output voltage: AC 250 V DC: see limit curve for arc-free operation Thermal current I : see continuous current limit curve th (max. 10 A in one contact path) Switching capacity to AC 15: 5 A / AC 230 V IEC/EN 60 947-5-1 for NO contact 2 A / AC 230 V IEC/EN 60 947-5-1 for NC contact Electrical life: 5 to AC 15 at 2 A, AC 230 V: 10 switching cycles IEC/EN 60 947-5-1 Permissible operating frequency: 600 switching cycles / h Short circuit strength max. fuse rating: 6 A gL IEC/EN 60 947-5-1 2

Tariff Desc

8536.49.00 TC 17103979 RELAYS, PRINTED CIRCUIT BOARD

8536.41 TC 8909066 RELAYS, having a continuous contact rating of NOT less than 3A and body dimensions NOT exceeding 40mm x 30mm x 27mm

8536.49.00 TC 9613322 RELAYS, low profile, OTHER THAN reed relays, being EITHER of the following:
(a) height NOT exceeding 21.24 mm;
(b) height NOT exceeding 35 mm and having a continuous current rating NOT less than 8A AC

8536.49 TC 8906734 RELAYS, having ALL of the following:
(a) one, two or three contacts;
(b) maximum continuous contact current rating of NOT less than 15A;
(c) maximum contact voltage rating of NOT less than 380V;
(d) maximum switched power rating of NOT less than 4000VA

8536.49.00 TC 1122469 RELAYS, having an operating voltage NOT exceeding 250 volts, having ANY of the following:
(a) spring loaded terminals
(b) plug-in screw terminals
(c) wire connected terminals

8536.41 TC 8534635 RELAYS, cradle, having ALL of the following:
(a) maximum switching current NOT exceeding 5 A (AC or DC);
(b) switching voltage NOT exceeding 250 V (AC or DC);
(c) body dimensions NOT exceeding 31 mm x 36 mm x 19 mm

8536.49 TC 8633667 RELAYS, vacuum, hermetically sealed

8536.41.00 TC 19144923 RELAYS, SWITCH AMPLIFIER, having a supply voltage NOT greater than 40v

8536.49 8633669 RELAYS, thermal overload, having ALL of the following characteristics:
(a) trip time NOT exceeding 5 s at 6 times full load current
(b) manual reset
(c) maximum current 50A

8536.49 TC 8633636 RELAYS, power appliance, 15A, having EITHER 2 contacts or 3 contacts

8536.41 TC 8438513 RELAYS, mercury wetted, contact type

8536.41 TC 8438500 RELAYS, coaxial

Looking for help? Visit our FAQ's Section to answer to all your questions

 

X-ON Worldwide Electronics

Welcome To X-ON ELECTRONICS
For over three decades, we have been advocating and shaping the electronic components industry. Our management complements our worldwide business scope and focus. We are committed to innovation, backed by a strong business foundation. If you need a trustworthy supplier of electronic components for your business – look no further.
 

Copyright ©2024  X-ON Electronic Services. All rights reserved.
Please ensure you have read and understood our Terms & Conditions before purchasing.
All prices exclude GST.

Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted