MOTOR PROTECTION,START.PKZM0 Part no. PKZM0-0,4 Article no. 072732 as a 690 V AC voltmeter protective device Delivery programme Connection technique Screw terminals 220 240 V AC-3 220 V 230 V 240 V P kW 0.06 380 V 400 V 415 V P kW 0.09 440 V P kW 0.12 500 V P kW 0.12 660 V 690 V P kW 0.18 Rated uninterrupted current I A 0.4 u Setting range Overload releases I A 0.25 0.4 r Short-circuit releases I A rm Notes Accessories 3 Standard auxiliary contact 072896 5 Trip-indicating auxiliary contact 072898 6 Shunt release, undervoltage release 073187 Single-phasing sensitivity to IEC/EN 60947-4-1 Can be snap-fitted to IEC/EN 60715 top-hat rail with 7.5 or 15 mm height 266164 PTB 02 ATEX 3151, see manual General Standards IEC/EN 60947, VDE 0660, UL 508, CSA C 22.2 No. 14 Climatic proofing Damp heat, constant, to IEC 60068-2-78 Damp heat, cyclic, to IEC 60068-2-30 Ambient temperature C Storage C & 8211 25 - 80 Open C & 8211 25 55 Enclosed C - 25 40 Mounting position Mounting position Direction of incoming supply As required Degree of protection 07/28/2010 1Device IP 20 Terminations IP00 Protection against direct contact Finger and back-of-hand proof Mechanical shock resistance half-sinusoidal shock 10 ms to IEC g 25 60068-2-27 Altitude m 2000 2 Terminal capacity screw terminals mm 2 Solid 1 (1 6) mm 2 (1 6) 2 Flexible with ferrule to DIN 46228 1 (1 6) mm 2 (1 6) Solid or stranded AWG 18 10 Terminal capacity springloaded terminals 2 Solid 1 (12.5) mm 2 (12.5) 2 Flexible with ferrule to DIN 46228 1 (12.5) mm 2 (12.5) Solid or stranded AWG 1814 Specified tightening torque for terminal screws Main cable Nm 1.7 Control circuit cables Nm 1 Main conducting paths Rated impulse withstand voltage U V AC 6000 imp Overvoltage category/pollution degree III/3 Rated operational voltage U V AC 690 e Rated uninterrupted current = rated operational current I = I A 32 or current setting of the overcurrent release u e Rated frequency Hz 40 60 Current heat loss (3 pole at operating temperature) W 6 6 Lifespan, mechanical Operations 0.1 10 6 Lifespan, electrical (AC-3 at 400 V) Operations 0.1 10 Maximum operating frequency Ops./h Max. operating frequency Ops/h 40 Short-circuit rating AC Engineering DC Short-circuit rating kA 60 Short-circuit rating 60 (up to PKZM0-16) 40 (PKZM0-20 to PKZM0-32) Motor switching capacity kA rms AC-3 (up to 690 V) A 32 DC-5 (up to 250 V) A 25 (3 contacts in series) Trip blocks Temperature compensation to IEC/EN 60947, VDE 0660 C & 8211 5 40 Operating range C & 8211 25 55 Temperature compensation residual error for T > 40 C %/K 0.25 Setting range of overload releases I 0.6 1 u Short-circuit release fixed I 14 u Short-circuit release tolerance % & 177 20 Phase-failure sensitivity IEC/EN 60947-4-1, VDE 0660 Part 102 Motor-protective circuit-breaker tripping characteristic (high-capacity) compact starter, PKZM0-...T (not for PKM0-...), PKZM01 Dimensions 07/28/2010 2