R3G190-RC05-03 Operating instructions ebm-papst Mulfingen GmbH & Co. KG 1. SAFETY REGULATIONS AND NOTES Bachmhle 2 Please read these operating instructions carefully before starting to work D-74673 Mulfingen with the device. Observe the following warnings to prevent malfunctions Phone +49 (0) 7938 81-0 or physical damage to both property and people. Fax +49 (0) 7938 81-110 These operating instructions are to be regarded as part of this device. info1 de.ebmpapst.com If the device is sold or transferred, the operating instructions must www.ebmpapst.com accompany it. CONTENTS These operating instructions may be duplicated and forwarded for information about potential dangers and their prevention. 1. SAFETY REGULATIONS AND NOTES 1 1.1 Levels of hazard warnings 1.1 Levels of hazard warnings 1 These operating instructions use the following hazard levels to indicate 1.2 Staff qualification 1 1.3 Basic safety rules 1 potentially hazardous situations and important safety regulations: 1.4 Electrical voltage 1 DANGER 1.5 Safety and protective functions 2 Indicates an imminently hazardous situation which, if not 1.6 Electromagnetic radiation 2 avoided, will result in death or serious injury. Compliance with 1.7 Mechanical movement 2 the measures is mandatory. 1.8 Emission 2 1.9 Hot surface 2 WARNING Indicates a potentially hazardous situation which, if not avoided, 1.10 Transport 2 could result in death or serious injury. Exercise extreme 1.11 Storage 2 caution while working. 2. PROPER USE 3 CAUTION Indicates a potentially hazardous situation which, if not avoided, 3. TECHNICAL DATA 4 may result in minor or moderate injury or damage of property. 3.1 Product drawing 4 3.2 Nominal data 5 NOTE 3.3 Technical features 5 A potentially harmful situation can occur and, if not avoided, can 3.4 Mounting data 5 lead to property damage. 3.5 Transport and storage conditions 5 3.6 Electromagnetic compatibility 5 1.2 Staff qualification The device may only be transported, unpacked, installed, operated, 4. CONNECTION AND START-UP 6 maintained and otherwise used by qualified, trained and authorised 4.1 Connecting the mechanical system 6 technical staff. 4.2 Connecting the electrical system 6 Only authorised specialists are permitted to install the device, to carry 4.3 Connection of the cables 6 out a test run and to perform work on the electrical installation. 4.4 Connection screen 7 4.5 Checking the connections 8 1.3 Basic safety rules 4.6 Switch on device 8 4.7 Switching off the device 8 Any safety hazards stemming from the device must be re-evaluated once it is installed in the end device. 5. INTEGRATED PROTECTIVE FUNCTIONS 8 Observe the following when working on the unit: Do not make any modifications, additions or conversions to the 6. MAINTENANCE, MALFUNCTIONS, POSSIBLE 8 device without the approval of ebm-papst. CAUSES AND REMEDIES 6.1 Cleaning 9 1.4 Electrical voltage 6.2 Safety test 9 Check the electrical equipment of the device at regular intervals, refer 6.3 Disposal 9 to chapter 6.2 Safety test. Replace loose connections and defective cables immediately. DANGER Electrical load on the device Risk of electric shock Stand on a rubber mat if you are working on an electrically charged device. WARNING Terminals and connections have voltage even with a unit that is shut off Electric shock Wait five minutes after disconnecting the voltage at all poles before opening the device. Item no. 51030-5-9970 ENG Revision 89188 Release 2016-04-18 Page 1 / 10 ebm-papst Mulfingen GmbH & Co. KG Bachmhle 2 D-74673 Mulfingen Phone +49 (0) 7938 81-0 Fax +49 (0) 7938 81-110 info1 de.ebmpapst.com www.ebmpapst.com Translation of the original operating instructionsR3G190-RC05-03 Operating instructions CAUTION Do not wear any loose-fitting or dangling clothing or jewellery In the event of failure, there is electric voltage at the while working on rotating parts. Protect long hair with a cap. rotor and impeller 1.8 Emission The rotor and impeller are base insulated. Do not touch the rotor and impeller once they are installed. WARNING Depending on the installation and operating conditions, CAUTION a sound pressure level greater than 70 dB(A) may arise. If control voltage is applied or a speed setpoint is stored, Danger of noise-induced hearing loss the motor will restart automatically, e.g. after a mains failure. Take appropriate technical safety measures. Risk of injury Protect operating personnel with appropriate safety Keep out of the device hazard zone. When working on the equipment, e.g. hearing protection. device, switch off the mains power and ensure that it cannot Also observe the requirements of local agencies. be switched back on. 1.9 Hot surface Wait until the device stops. After working on the device, remove any tools used or CAUTION other objects from the device. High temperature at the electronics housing Risk of burns 1.5 Safety and protective functions Ensure sufficient contact protection. DANGER 1.10 Transport Protective device missing and protective device not functioning NOTE Without a protective device there is a risk of serious injury, for Transporting the device instance when reaching into the device during operation. Transport the device in its original packaging only. Operate the device only with a fixed protective device and guard grille. The fixed protective device must be able to 1.11 Storage withstand the kinetic energy of a fan blade that becomes detached at maximum speed. There must not be any gaps Store the device, partially or fully assembled, in the original packaging in a clean, dry and weatherproof place free of vibrations. which it is possible to reach into with the fingers, for example. Protect the device against environmental effects and dirt until final The device is a built-in component. As the operator, you installation. are responsible for ensuring that the device is secured adequately. We recommend storing the device for no longer than one year in order to guarantee trouble-free operation and longest possible service Stop the device immediately if a protective device is life. found to be missing or ineffective. Even devices explicitly intended for outdoor use are to be stored as 1.6 Electromagnetic radiation described prior to commissioning. Interference from electromagnetic radiation is possible, e.g. in conjunction Maintain the storage temperature, see with open and closed-loop control devices. chapter 3.5 Transport and storage conditions. If unacceptable emission intensities occur when the fan is installed, appropriate shielding measures have to be taken by the user. NOTE Electrical or electromagnetic interferences after integrating the device in installations on the customer s side. Verify that the entire setup is EMC compliant. 1.7 Mechanical movement DANGER Rotating device Body parts that come into contact with the rotor and impeller can be injured. Secure the device against accidental contact. Before working on the system/machine, wait until all parts have come to a standstill. WARNING Rotating device Long hair, dangling items of clothing, jewellery and similar items can become entangled and be pulled into the device. Risk of injury. Item no. 51030-5-9970 ENG Revision 89188 Release 2016-04-18 Page 2 / 10 ebm-papst Mulfingen GmbH & Co. KG Bachmhle 2 D-74673 Mulfingen Phone +49 (0) 7938 81-0 Fax +49 (0) 7938 81-110 info1 de.ebmpapst.com www.ebmpapst.com Translation of the original operating instructions