Ericsson Internal Ericsson Internal E PRODUCT STABLE OF CONTEPECIFICATION NTS 1 (4)1 (2) PrPreparepareedd ( (aallsso so subjubjecectt r reesponsisponsibbllee i iff othotheerr)) NNoo EZHIXZH 1/1301EZHIXZH 001 52-BMR - EN/L636 ZT 146 39Uen 4 Uen Technical Speci cation ApprApprovoved Ced Checked hecked DDate ate RReevv RRefereferencence e EN/LZT 146 394 R5D October 2013 PKB 4000 series SEC/D (Julia SEC/D (Betty Wu) You) MICJOHN 20112009-02-8-7 -24 C E Ericsson AB DC/DC converters, Input 36-75 V, Output 30 A/90 W Key Features Industry standard Eighth-brick 58.4 x 22.7 x 8.10 mm (2.30 x 0.894 x 0.32 in.) Low profile, max 8.10 mm (0.32 in.) High efficiency, typ. 90.6 % at half load 2250 Vdc input to output isolation Meets isolation requirements equivalent to basic insulation according to IEC/EN/UL 60950 More than 4.7 million hours predicted MTBF at +40C ambient temperature General Characteristics Suited for narrow board pitch applications (15 mm/0.6 in) Output over voltage protection Input under voltage shutdown Over temperature protection Safety Approvals Design for Environment Output short-circuit protection Remote sense Remote control Output voltage adjust function Meets requirements in high- Highly automated manufacturing ensures quality temperature lead-free soldering ISO 9001/14001 certified supplier processes. Contents General Information .............................................................2 Safety Specification .............................................................3 Absolute Maximum Ratings .............................................................4 Product Program Ordering No. 1.0V, 30A / 30W Electrical Specification PKB 4318N PINB.................................. 5 1.2V, 30A / 36W Electrical Specification PKB 4318 PIOBNB............................... 8 1.5V, 30A / 45W Electrical Specification PKB 4418 PIOANB ............................. 11 1.8V, 25A / 45W Electrical Specification PKB 4418 PINB .................................. 14 2.5V, 25A / 62.5W Electrical Specification PKB 4619 PINB .................................. 17 3.3V, 20A / 66W Electrical Specification PKB 4610 PINB .................................. 20 3.3V, 25A / 82.5W Electrical Specification PKB 4810 PINB .................................. 23 5.0V, 15A / 75W Electrical Specification PKB 4711 PINB .................................. 26 12V, 6A / 72W Electrical Specification PKB 4713 PINB .................................. 29 12V, 7.5A / 90W Electrical Specification PKB 4913 PINB .................................. 32 15V, 5A / 75W Electrical Specification PKB 4715 PINB .................................. 35 EMC Specification ........................................................... 38 Operating Information ...........................................................39 Thermal Consideration ...........................................................40 Connections ...........................................................41 Mechanical Information ...........................................................42 Soldering Information ...........................................................44 Delivery Information ...........................................................45 Product Qualification Specification ...........................................................46 Ericsson Internal E PRODUCT SPECIFICATION 2 (4) Prepared (also subject responsible if other) No. EZHIXZH 1/1301-BMR 636 Uen 2 Technical Speci cation Approved Checked Date Rev Reference EN/LZT 146 394 R5D October 2013 PKB 4000 series SEC/D (Julia You) MICJOHN 2011-02-24 C Ericsson AB DC/DC converters, Input 36-75 V, Output 30 A/90 W Conservative design rules, design reviews and product General Information qualifications, plus the high competence of an engaged work force, contribute to the high quality of the products. Ordering Information See Contents for individual product ordering numbers. Warranty Warranty period and conditions are defined in Ericsson Option Suffix Ordering No. Power Modules General Terms and Conditions of Sale. Isolated Surface mount SI PKB 4711 SINB Positive Remote Control Logic P PKB 4711 PIPNB Limitation of Liability Increased stand-off height M PKB 4711 PINBM Lead length 3.69 mm (0.145 in) LA PKB 4711 PINBLA Ericsson Power Modules does not make any other Lead length 4.57 mm (0.180 in) LB PKB 4711 PINBLB warranties, expressed or implied including any warranty of Note : As an example a positive logic, increased standoff, short pin product merchantability or fitness for a particular purpose would be PKB 4711 PIPNBMLA. (including, but not limited to, use in life support Reliability applications, where malfunctions of product can cause injury to a persons health or life). The failure rate () and mean time between failures (MTBF= 1/ ) is calculated at max output power and an operating Ericsson AB 2013 ambient temperature (T ) of +40C. Ericsson Power A The information and specifications in this technical Modules uses Telcordia SR-332 Issue 2 Method 1 to specification is believed to be correct at the time of calculate the mean steady-state failure rate and standard publication. However, no liability is accepted for deviation ( ). inaccuracies, printing errors or for any consequences thereof. Ericsson AB reserves the right to change the Telcordia SR-332 Issue 2 also provides techniques to contents of this technical specification at any time without estimate the upper confidence levels of failure rates based prior notice. on the mean and standard deviation. Mean steady-state failure rate, Std. deviation, 214 nFailures/h 34.5 nFailures/h MTBF (mean value) for the PKB series = 4.7 Mh. MTBF at 90% confidence level = 3.9 Mh Compatibility with RoHS requirements The products are compatible with the relevant clauses and requirements of the RoHS directive 2002/95/EC and have a maximum concentration value of 0.1% by weight in homogeneous materials for lead, mercury, hexavalent chromium, PBB and PBDE and of 0.01% by weight in homogeneous materials for cadmium. Exemptions in the RoHS directive utilized in Ericsson Power Modules products are found in the Statement of Compliance document. Ericsson Power Modules fulfills and will continuously fulfill all its obligations under regulation (EC) No 1907/2006 concerning the registration, evaluation, authorization and restriction of chemicals (REACH) as they enter into force and is through product materials declarations preparing for the obligations to communicate information on substances in the products. Quality Statement The products are designed and manufactured in an industrial environment where quality systems and methods like ISO 9000, Six Sigma, and SPC are intensively in use to boost the continuous improvements strategy. Infant mortality or early failures in the products are screened out and they are subjected to an ATE-based final test.