Ericsson Internal Ericsson Internal E TABLE OF CONTEPRODUCT SPECIFICATION NTS 1 (1)1 (4) PrPreparepareedd ( (aallsso so subjubjecectt r reesponsisponsibbllee i iff othotheerr)) NNoo SEC/S Kevin SEC/S Kevin Zhou Zhou 1/130100152-E-BMR N/LZ638/2 Uen T146380 Uen Technical Speci cation ApprApprovoved Ced Checked hecked DDate ate RReevv RRefereferencence e EN/LZT 146 380 R2B March 2011 PKY 4000 PI series 20112011-02-03--24 09 E D Ericsson Power Modules AB DC/DC converters, Input 36-75 V, Output up to 25 A/700 W Key Features Full-brick Industry Standard 116.8 x 61.0 x 12.7 mm (4.6 x 2.4 x 0.50 in.) High efficiency, typ. 95 % at 28 Vout within 30%-100% load range. 1500 Vdc input to output isolation Meets isolation requirements equivalent to basic insulation according to IEC/EN/UL 60950 2.6 million hours MTBF General Characteristics Excellent thermal performance Output over voltage protection Input over voltage protection Input under voltage shutdown Over temperature protection Monotonic startup Safety Approvals Design for Environment Remote sense Remote control Over current protection Output voltage adjust function Meets requirements in high- Power Good Function. temperature lead-free soldering AUX voltage 10V, 50mA processes. Highly automated manufacturing ensures quality ISO 9001/14001 certified supplier Contents General Information .............................................................2 Safety Specification .............................................................3 Absolute Maximum Ratings .............................................................4 Electrical Specification Ordering No. 28 V, 21.5A / 600W PKY 4616 PI ......................................... 5 28 V, 25A / 700W PKY 4716 PI ......................................... 9 EMC Specification ........................................................... 13 Operating Information ...........................................................14 Thermal Consideration ...........................................................16 Connections ...........................................................17 Mechanical Information ...........................................................18 Soldering Information ...........................................................19 Delivery Information ...........................................................19 Product Qualification Specification ...........................................................20 Ericsson Internal E PRODUCT SPECIFICATION 2 (4) Prepared (also subject responsible if other) No. SEC/S Kevin Zhou 1/1301-BMR 638/2 Uen 2 Technical Speci cation Approved Checked Date Rev Reference EN/LZT 146 380 R2B March 2011 PKY 4000 PI series 2011-02-24 E Ericsson Power Modules AB DC/DC converters, Input 36-75 V, Output up to 25 A/700 W qualifications, plus the high competence of an engaged General Information work force, contribute to the high quality of the products. Ordering Information Warranty See Contents for individual product ordering numbers. Warranty period and conditions are defined in Ericsson Power Modules General Terms and Conditions of Sale. Option Suffix Ordering No. Standard PKY 2616 PI Limitation of Liability Non-threaded stand off M PKY 2616 PIM Negative Remote Control logic N PKY 2616 PIN Ericsson Power Modules does not make any other warranties, expressed or implied including any warranty of Note: As an example a negative logic with non-threaded stand off product merchantability or fitness for a particular purpose would be PKY 2616 PINM. (including, but not limited to, use in life support Reliability applications, where malfunctions of product can cause The failure rate () and mean time between failures (MTBF= injury to a persons health or life). 1/ ) is calculated at max output power and an operating ambient temperature (T ) of +40C. Ericsson Power Ericsson AB 2011 A Modules uses Telcordia SR-332 Issue 2 Method 1 to The information and specifications in this technical calculate the mean steady-state failure rate and standard specification is believed to be correct at the time of deviation ( ). publication. However, no liability is accepted for inaccuracies, printing errors or for any consequences Telcordia SR-332 Issue 2 also provides techniques to thereof. Ericsson AB reserves the right to change the estimate the upper confidence levels of failure rates based contents of this technical specification at any time without on the mean and standard deviation. prior notice. Mean steady-state failure rate, Std. deviation, 381nFailures/h 37.3 nFailures/h MTBF (mean value) for the PKY series = 2.6 Mh. MTBF at 90% confidence level = 2.3 Mh Compatibility with RoHS requirements The products are compatible with the relevant clauses and requirements of the RoHS directive 2002/95/EC and have a maximum concentration value of 0.1% by weight in homogeneous materials for lead, mercury, hexavalent chromium, PBB and PBDE and of 0.01% by weight in homogeneous materials for cadmium. Exemptions in the RoHS directive utilized in Ericsson Power Modules products are found in the Statement of Compliance document. Ericsson Power Modules fulfills and will continuously fulfill all its obligations under regulation (EC) No 1907/2006 concerning the registration, evaluation, authorization and restriction of chemicals (REACH) as they enter into force and is through product materials declarations preparing for the obligations to communicate information on substances in the products. Quality Statement The products are designed and manufactured in an industrial environment where quality systems and methods like ISO 9000, Six Sigma, and SPC are intensively in use to boost the continuous improvements strategy. Infant mortality or early failures in the products are screened out and they are subjected to an ATE-based final test. Conservative design rules, design reviews and product