EETTAA--UUSSAA AOLL1-100 100W Exterior LED Driver FEATURES: Universal AC input 90~264 VAC Built in active PFC IP66 or IP67 for damp locations designed for outdoor use Wide Temp -40 ~ +70 range Adjustable output voltage and current UL 8750 safety (Pending) Warranty: 4 years Output voltage and constant current level can be adjusted through potential meter. Constant current level adjustable through output cable with 1~10Vdc. Pending MODEL/CHANNEL Unit AOLL1-240-12 AD AOLL1-240-24 AD AOLL1-240-48 AD OUTPUT Norminal Voltage V 12 24 48 Setting Voltage Range V 11.8 ~ 12.1 23.7 ~ 24.3 47.5 ~ 48.5 Voltage ADJ. Range *note1 V 10.8 ~ 13.5 22.0 ~ 27.0 43.0 ~ 53.0 Norminal Current A 6.4 4 2 Current ADJ. Range *note1 4.16 ~ 6.4 2.6 ~ 4 1.3 ~ 2 A Line Regulations mV 120 120 240 Load Regulations mV 120 120 240 180 360 720 Temperature Drift mV 120 120 150 Ripple Max. mV 150 150 250 Ripple & Noise Max 1. mV mV 400 400 600 Ripple & Noise Max 2. *note2 ms 1000 (AC IN 100V, Io=100%) Turn-on Time Typ. 17 (AC IN 100V, Io=100%) ms Hold-up Time Typ. AC100 - 240(AC 90-264, 50/60Hz(47 - 63) or DC127-370V (Universal Input) V Typ. Voltage, Frequency INPUT Current Typ. 110V 3.0 3.0 3.0 A 220V 1.5 1.5 1.5 Efciency Typ. 110V 87 88 90 % 220V 90 92 93 Power factor Typ. 110V 0.99 0.99 0.99 - 220V 0.98 0.98 0.98 Inrush Current Typ. 110V 25 ( Ta=25 , Cold Start ) A 220V 45 ( Ta=25 , Cold Start ) Leakage Current Max. 110V 3.5 mA mA 220V 3.5 Function Over Voltage Protection 110% ~ 160% of rating V Over Current Protection Blank,D A 95 ~ 110 % 95 ~ 110 % 95 ~ 110 % Over Current Protection A,AD A 60 ~ 100 % 60 ~ 100 % 60 ~ 100 % Short Circuit Hiccup mode, recovers automatically after fault condition is removed - Cooling / O.T.P - Convection/Optional AC 3.0KV 1min, cut-off: 20mA / DC 500V 100 Electrical - (1) Input - Output Isolation AC 2.0KV 1min, cut-off: 20mA / DC 500V 100 (2) Input - F.G - (3) Output - F.G - AC 0.5KV 1min, cut-off:100mA / DC 500V 100 -40 ~ +70(Required Derating), 20 ~ 90%RH (Non Condensing) Environment - Operating temp. & Humidity Storage temp. & Humidity -40 ~ +75, 20 ~ 90% RH (Non Condensing) - Vibration - 10~55Hz at 1G 3minutes period, 30minutes along X,Y and Z axis Dimension Size(WxHxD) / Weight mm/g 68 x 39 x 189 / 824 - CE Built to meet UL8750 Safety - Emission Built to meet EN55015 Conducted Emission - *note1 : Type A,AD only *note2 : Frequency 50/60Hz ETA-USA 16170 Vineyard Blvd. Suite 180 Morgan Hill, CA 95037 ETETAA--UUSSAA AOLL1-100 100W Exterior LED Driver 1. BLOCK DIAGRAM EMI FILTER & PFC POWER RECTIFIERS RECTIFIERS CIRCUIT SWITCHING CIRCUIT V A DETECTION CIRCUIT O.L.P PWM PFC CONTROL CONTROL O.T.P OVP DETECTION 2. Terminal Connection Cable1 Cable1 Cable3 0.75mmx3C 0.75mmx3C 0.75mm2C 2.5mm2C 2.5mm2C AOLL1-100-24 AOLL1-100-24-D Cable2 Cable2 Cable1 Cable1 Cable3 0.75mmx3C 0.75mm2C 0.75mmx3C 2.5mm2C 2.5mm2C AOLL1-100-24-A AOLL1-100-24-AD Cable2 Cable2 OUTPUT VOLTAGE ADJUSTER OUTPUT VOLTAGE ADJUSTER OUTPUT CURRENT ADJUSTER OUTPUT CURRENT ADJUSTER Cable Type Wire Color Terminal BROWN AC (L) 2 Cable1 SKY BLUE AC (N) 60227 0.75mm X 3C YELLOW/GREEN FG BROWN Output + 2 Cable2 60227 2.5mm X 2C SKY BLUE Output - BROWN Dimming + 2 Cable3 60227 0.75mm X 2C SKY BLUE Dimming - * Size and Type for cable subject to change * Cable3 applies to D and AD type only ETA-USA 16170 Vineyard Blvd. Suite 180 Morgan Hill, CA 95037