Thermal Overcurrent Circuit Breaker 1180-... Description Miniaturised single pole thermal circuit breaker with switching function optional (push-push actuation). Reliable snap-acting and trip-free mechanism. Approved to CBE standard EN/IEC 60934. S-type, TO. Blade terminals fitting into sockets for rail mounting. Typical applications Protection of loads in power distribution systems in control cabinets and process control. 1 1180-... Features and benefits Your benefits l Easy mounting due to plug-in design matching standard l Space-savings of more than 50 % compared to MCBs terminal blocks l Significantly higher system availability than provided by fuses l Fine grading of current ratings, particularly in the range of thanks to resettability small ratings l Rating options selectable for optimum equipment protection l Very small width of only 8.2 mm l Universally suitable for AC and DC applications Preferred types for more details on all configurations please see order numbering code Preferred types are E-T-A products most frequently used by E-T-A volumes. Our preferred types are supplied at shorter lead times than customers. We manufacture E-T-A preferred types in particularly high non-standard versions. Preferred types Standard current ratings (A) 0.5 1 1.5 2 2.5 3 4 5 6 8 10 x x x x x x x x x x x 1180-01- Approvals Information online The current data sheet is available on our website: www.e-t-a.de/e004 Compliances 2043 www.e-t-a.de 1Thermal Overcurrent Circuit Breaker 1180-... Technical data Technical data Interrupting capacity I 0,15 A 6 x I AC 250 V, DC 65 V cn N Voltage rating AC 250 V DC 65 V 610 A 8 x I AC 250 V, DC 65 V N (UL, UL Canada: AC 250 V DC 72 V) 0,10,7 A 25 x I DC 30 V N Current ratings 0.1...10 A 0,86 A 10 x I DC 30 V N Typical life 6,000 operations at 1 x I (low-inductance) 710 A 20 x I DC 30 V N N 3,000 operations at 1 x I (inductive) N Interrupting capacity AC 250 V 2,000 A 500 operations at 2 x I (inductive) N (UL 1077) DC 72 V 2,000 A Ambient temperature -20...+60 C (T 60) -4...+140 F Degree of protection operating area IP40 Insulation co-ordination rated impulse pollution (IEC 60529/DIN 40050) terminal area IP00 (IEC 60664 and 60664 A) withstand voltage degree Vibration 5 g (57-500 Hz) 0.38 mm (10-57 Hz) 2.5 kV 2 without terminal block to IEC 60068-2-6, test Fc, reinforced insulation in operating area 10 frequency cycles/axis and to EN 50155 1 Dielectric strength Shock 25 g (11 ms) (IEC 60664 and 60664A) test voltage without terminal block to IEC 60068-2-27, test Ea operating area AC 3,000 V Corrosion 96 hours at 5 % salt mist, installation area AC 1,500 V to IEC 60068-2-11, test Ka Insulation resistance > 100 M (DC 500 V) Humidity 240 hours at 95 % RH to IEC 60068-2-78, test Cab Mass approx. 10 g Preferred types Preferred types are E-T-A products most frequently used by E-T-A volumes. Our preferred types are supplied at shorter lead times than customers. We manufacture E-T-A preferred types in particularly high non-standard versions. Preferred types Standard current ratings (A) 0.5 1 1.5 2 2.5 3 4 5 6 8 10 x x x x x x x x x x x 1180-01- Ordering information Approvals Type No. Authority Standard Rated voltage Current ratings 1180 single pole thermal circuit breaker, plug-in mounting VDE IEC/EN AC 250 V 0.1 A10 A Versions 60934 DC 65 V 0.1 A10 A 01 with switching function, without label 02 reset function only, without label UL UL 1077 AC 250 V / 50/60 Hz 0.1 A10 A Current rating range C22.2 No 235 DC 72 V 0.1 A10 A 0.1...10 A CSA C22.2 No 235 AC 250 V 0.1 A10 A 1180 - 01 - 1 A ordering example DC 72 V 0.1 A10 A CQC GB/T17701 AC 250 V, 0,1...10 A DC 65 V 2 www.e-t-a.de 2043